NetBackup Appliance Upgrade Readiness Analyzer
对于3.2版本,请安装SYMC_NBAPP_update_ReadinessAnalyzer-8.0.3-1.noarch.rpm
检查条目显示[WARNING]的可以忽略.看不到[NOT OK]后,即可安装升级包。
这时画面会显示 “The upgrade readiness analysis passed”
Install SYMC_NBAPP_update_ReadinessAnalyzer-8.0.3-1.noarch.rpm
NetBackup Appliance 3.3.0.2 Maintenance Release 2
-----SYMC_NBAPP_update_MaintenanceRelease-3.3.0.2-20211115091121.x86_64.rpm
Install SYMC_NBAPP_update_MaintenanceRelease-3.3.0.2-20211115091121.x86_64.rpm
NetBackup 8.3.0.2 / 3.3.0.2 Hotfix - MSDP Preferred EEB Bundle (Etrack 4045322)
-----NBAPP_EEB_ET4045322-3.3.0.2-5.x86_64.rpm
Install NBAPP_EEB_ET4045322-3.3.0.2-5.x86_64.rpm
2.在Shell中输入如下命令打开 NFS 和CIFS 共享:
Main_Menu > Manage > Software > Share Open
3. 通过Windows路径访问如下共享路径或做网络磁盘映射:
\\<appliance-name>\incoming patches
\\172.18.12.100\incoming patches(加域电脑无法打开共享)
Install SYMC_NBAPP_update_ReadinessAnalyzer-8.0.3-1.noarch.rpm
- [Error] V-409-777-1022: Checking last appliance reboot check failed. This appliance was last rebooted more than 14 days ago. You must first reboot this appliance. Reboot time will vary depending on the appliance configuration. After rebooting, run the Appliance Upgrade Readiness Analyzer again.
V-409-777-1022:检查上次设备重启检查失败。这台设备最近一次重启是在14天前。您必须首先重新启动该设备。重新启动的时间取决于设备配置。重新引导后,再次运行设备升级准备分析器
Main_Menu > Manage > Software > List Downloaded
Install SYMC_NBAPP_update_ReadinessAnalyzer-8.0.3-1.noarch.rpm
6.安装3.3.0.2更新包
Install SYMC_NBAPP_update_MaintenanceRelease-3.3.0.2-20211115091121.x86_64.rpm
Main_Menu > Manage > Software > UpgradeStatus
通过Main_Menu > Manage > Software >List Downloaded
通过Main_Menu > Manage > Software >Share open重新上传