AIX下的MPIO、RDAC、SDDPCM多路径软件操作

一:查看存储盘的路径

1、查看MPIO的存储盘的路径
# lspath                                    (适用于所有存储的MPIO路径查询)
# mpio_get_config  -Av              (适用于DS3K/DS4K的MPIO路径查询)

2、查看RDAC存储盘的路径
# fget_config -Av                       (适用于DS3K/DS4K的RDAC路径查询)

3、查看SDDPCM存储盘的路径
# pcmpath query device              (适用于DS6K/DS8K和v7000的SDDPCM路径查询)

4、查看当前操作系统自带的支持IBM存储的多路径软件
# manage_disk_drivers

5、将DS4700默认的多路径软件更改成RDAC
# manage_disk_drivers -d DS4700 -o AIX_fcparray

二:MPIO路径的常用操作

1、查看单个盘的路径
# lspath -l hdisk3
# lspath -F "status name path_id parent connection" | grep -w hdisk3

2、MPIO路径控制
将fcs0卡下的hdisk2的路径禁用
# chpath -l hdisk2 -p fscsi0 -s disable

将fcs0卡下的hdisk2的路径启用
# chpath -l hdisk2 -p fscsi0 -s enable

3、其它参数
# chdev -l hdisk3 -a queue_depth=1          //如果ODM是1.0.1.0以上可以是任何数字

# chdev -l hdisk3 -a hcheck_interval=60     //链路失效检查时间间隔;如果等0,则不会自检

# chdev -l hdisk3 hcheck_mode=nonacive
This parameter specifies which I/O paths should be monitored by the path health checking functionality.
nonactive: This mode will check all failed I/O paths and all standby paths of used/opened devices.
failed: This mode with check failed I/O paths only.
enabled: This mode will check all enabled I/O paths which are opened.

Note:
Non-opened devices are not monitored. Also, this attribute is
not being used at this time since path health checking is not
enabled. This attribute can be ignored

4、修改链路优先级
lspath -AHE -l hdisk2 -p vscsi3                            //查看链路优先级
# chpath -l hdisk3 -p fscsi0 -w 链路1 -a priority=1
# chpath -l hdisk3 -p fscsi0 -w 链路2 -a priority=2

5、处理故障
1)如果发现有很多路径是missing的,可以用cfgmgr重新扫描,如果还有missing的,可以用步骤2和2来激活路径;
2)如果要更换光纤线,可以该卡上的有的路径禁用,换完线后再启用,避免直接拨线产生的风险。

  • 0
    点赞
  • 2
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
富士通AIX多路径软件 Storage systems can be connected to the following servers. IBM HBAs must be used for server connection. Check your server details. • Server hardware • Server OS When the Multipath Driver is used in a cluster configuration, use PowerHA (HACMP), which is a software product supplied by IBM Corp., and applications that support PowerHA (HACMP). Hardware name Remarks RS/6000 — pSeries — Power Systems — System p — When a storage system is connected to multiple servers, one of which is allowed to control the storage system power supply via an RCI connection or a power control box, make sure that the storage system and Fibre Channel switches are never turned off while any of the other servers are still running. If the storage system or Fibre Channel switch is turned off before the server shuts down, data may be lost. OS Fix Level AIX 5L V5.2 (*1) (*2) Technology Level 09-CSP or later AIX 5L V5.3 Technology Level 05-CSP or later AIX 6.1 Not required Virtual I/O Server (VIOS) 1.5 (*1) Not required Virtual I/O Server (VIOS) 2.1 (*1) Not required Chapter 2 Server Compatibility Requirements 2.2 Installing or Uninstalling the Multipath Driver ETERNUS Multipath Driver 2 User’s Guide for AIX 24 Copyright 2012 FUJITSU LIMITED P2U3-0051-03ENZ0 • Supported storage systems Fibre Channel ETERNUS DX60/DX60 S2 ETERNUS DX80/DX80 S2 ETERNUS DX90/DX90 S2 ETERNUS DX400/DX400 S2 series ETERNUS DX8000/DX8000 S2 series ETERNUS2000 ETERNUS4000 (*1) ETERNUS8000 ETERNUS3000 (*2) ETERNUS6000 (*2) iSCSI (*2) ETERNUS DX60/DX60 S2 ETERNUS DX80/DX80 S2 ETERNUS DX90/DX90 S2 ETERNUS DX400/DX400 S2 series ETERNUS DX8000/DX8000 S2 series ETERNUS2000 ETERNUS4000 ETERNUS8000

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值