ABAQUS仿真问题及解决方案整理
- 1. ERROR: Process terminated by external request (SIGTERM or SIGINT received).
- 2. Contact pair (Assembly_Set_cns, Assembly_surf-1) Node part-1-1.3402 is overclosed by 31.8295 which is too severe.
- 3. The analysis may need a large number of increments (more than 20000000) ,and it may be affected by round-off errors. For accuracy, running double precision executable is required.
1. ERROR: Process terminated by external request (SIGTERM or SIGINT received).
MSG: ERROR: Process terminated by external request (SIGTERM or SIGINT received).
LOG: Lost connection to driverLM. Will not attempt recovery. Exiting
原因:外部原因,非模型问题
解决方案:关掉360,重新运算
2. Contact pair (Assembly_Set_cns, Assembly_surf-1) Node part-1-1.3402 is overclosed by 31.8295 which is too severe.
原因:往往是因为接触面的法线方向定义反了。
解决方案:定义刚体和shell的surface时,注意选择外侧。