一、终端执行哪种脱机数据认证的依据:SDA,DDA,CDA
选择哪种脱机数据认证?
答:(1)、卡片对脱机数据认证的支持情况在AIP中即
第12本书中的P50处:
应用交互特征 Application Interchange Profile (AIP) | F: b 16 T: “84” L: 2 | 必备卡片数据元 | 说明此应用中卡片支持指定功能的能力 | N | GPO | 字节1 位 8 RFU 位7 1= 支持SDA 位6 1= 支持DDA 位5 1= 支持持卡人认证 位4 1= 支持终端风险管理 位3 1= 支持发卡行认证 位2 1= 支持CDA 位1 RFU 字节 2 位8 1 = 支持MSD 位7~1 RFU |
例如:7C 00 两个字节代表:0111 1100 0000 0000
(2)、终端对脱机数据认证方法的支持在终端性能中指示
表 0‑2: 终端性能
字节 1: 卡片数据输入性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 手工键盘输入 |
X | 1 | X | X | X | X | X | X | 磁条 |
X | X | 1 | X | X | X | X | X | 接触式IC卡 |
X | X | X | 0 | X | X | X | X | RFU |
X | X | X | X | 0 | X | X | X | RFU |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 0 | X | RFU |
X | X | X | X | X | X | X | 0 | RFU |
字节 2: CVM 性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | IC卡明文PIN验证 |
X | 1 | X | X | X | X | X | X | 加密PIN联机验证 |
X | X | 1 | X | X | X | X | X | 签名(纸) |
X | X | X | 1 | X | X | X | X |
|
X | X | X | X | 1 | X | X | X | 无需CVM |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 0 | X | RFU |
X | X | X | X | X | X | X | 1 | 持卡人证件验证 |
如果终端支持签名的CVM,则这个终端必须是服务员终端(终端类型= ‘X1’,‘X2’,或‘X3’)并且支持打印机(附加终端性能的字节 4‘打印,给服务员’位= ‘1’)。
字节3:安全性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 静态数据认证(SDA) |
X | 1 | X | X | X | X | X | X | 动态数据认证(DDA) |
X | X | 1 | X | X | X | X | X | 吞卡 |
X | X | X | 1 | X | X | X | X | 复合动态数据认证/应用密码生成(CDA) |
X | X | X | X | 0 | X | X | X | RFU |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 0 | X | RFU |
X | X | X | X | X | X | X | 0 | RFU |
A.1 附加终端性能
下面表中的‘1’表示,如果某位的值为‘1’,则对应的‘意义’被应用,而‘X’表示该位没有使用。
表 0‑3:附加终端性能
字节1:交易类型性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 现金 |
X | 1 | X | X | X | X | X | X | 商品 |
X | X | 1 | X | X | X | X | X | 服务 |
X | X | X | 1 | X | X | X | X | 返现 |
X | X | X | X | 1 | X | X | X | 查询 |
X | X | X | X | X | 1 | X | X | 转账 |
X | X | X | X | X | X | 1 | X | 付款 |
X | X | X | X | X | X | X | 1 | 管理 |
字节2:交易类型性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 存款交易 |
X | 0 | X | X | X | X | X | X | RFU |
X | X | 0 | X | X | X | X | X | RFU |
X | X | X | 0 | X | X | X | X | RFU |
X | X | X | X | 0 | X | X | X | RFU |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 0 | X | RFU |
X | X | X | X | X | X | X | 0 | RFU |
字节3:终端数据输入性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 数字键 |
X | 1 | X | X | X | X | X | X | 字母和特殊字符键 |
X | X | 1 | X | X | X | X | X | 命令键 |
X | X | X | 1 | X | X | X | X | 功能键 |
X | X | X | X | 0 | X | X | X | RFU |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 0 | X | RFU |
X | X | X | X | X | X | X | 0 | RFU |
字节4:终端数据输出性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 打印,给服务员 |
X | 1 | X | X | X | X | X | X | 打印,给持卡人 |
X | X | 1 | X | X | X | X | X | 显示,给服务员 |
X | X | X | 1 | X | X | X | X | 显示,给持卡人 |
X | X | X | X | 0 | X | X | X | RFU |
X | X | X | X | X | 0 | X | X | RFU |
X | X | X | X | X | X | 1 | X | 编码表10 |
X | X | X | X | X | X | X | 1 | 编码表9 |
编码表序号指ISO 8859对应的部分。
字节5:终端数据输出性能
B8 | B7 | B6 | B5 | B4 | B3 | B2 | B1 | 意义 |
1 | X | X | X | X | X | X | X | 编码表8 |
X | 1 | X | X | X | X | X | X | 编码表7 |
X | X | 1 | X | X | X | X | X | 编码表6 |
X | X | X | 1 | X | X | X | X | 编码表5 |
X | X | X | X | 1 | X | X | X | 编码表4 |
X | X | X | X | X | 1 | X | X | 编码表3 |
X | X | X | X | X | X | 1 | X | 编码表2 |
X | X | X | X | X | X | X | 1 | 编码表1 |