1,查看磁盘缓存策略[root@backupServer ~]# /opt/MegaRAID/MegaCli/MegaCli64 -LDGetProp -Cache -LAll -aAll
Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 1(target id: 1): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 2(target id: 2): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 3(target id: 3): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 4(target id: 4): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 5(target id: 5): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 6(target id: 6): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 7(target id: 7): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 8(target id: 8): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU
Adapter 0-VD 9(target id: 9): Cache Policy:WriteThrough, ReadAheadNone, Direct, No Write Cache if bad BBU2,定位磁盘,可定位多个磁盘如physdrv[0:4,0:5,0:6][root@backupServer ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PdLocate -start physdrv[0:4] -a0
Adapter: 0: Device at EnclId-0 SlotId-4 -- PD Locate Start Command was successfully sent to Fir