ArcEngine中的Spatial Refrence (转)

空间参考是GIS的基础,失去了空间参考信息,地理空间内所有的信息也就失去了存在的意义,因为它们是不准确的或是错误的。关于ArcGIS坐标系统文件,可以看看这篇文章——ArcGIS 坐标系统文件》。

刻画Spatial Reference的精度

首先,我们主要讨论的是ArcGISSpatial Reference的各种精度,看到resolutiontolerancedomainscale factorprecision,是否很熟悉?为了保证表达的准确性,所有这些关键字使用英文表述,不再译为中文。

    Resolutiondomain范围决定了Geometry坐标的存储方式,Resolution和关联的坐标系使用相同的数量单位,如当空间参考使用以米为单位的投影参考时,XY resolution单位为米,默认情况下resolution=0.0001m,不管怎么样resolution值至少应该小于数据精度的1/10。当定位某一坐标到坐标格网时,我们依据如下公式:

    Persisted coordinate = Round((map coordinate - minimum domain extent) / resolution)

    ArcGIS 9.2之前,resolution=1/precisionArcGIS 9.2认为resolutionprecision几乎相同,在9.2之前坐标的存储精度是31位,9.2中为53位,对于上面的公式而言,当resolution很小时,坐标系统表达数据会更精确,但在9.2之前的ArcGISpersisted coordinate会受到限制。例如在ArcGIS 9.2之前,当minimum domain val=0resolution=1时,maximum domain val=231-2resolution=0.0001时,maximum domain val="/(231-2)*0.0001=214748.3647;在ArcGIS 9.2中,当minimum domain val=0resolution=1时,maximum domain val=253-2resolution=0.0001时,maximum domain val="/(253-2)*0.0001,很显然,ArcGIS 9.1maximum domain val=214748.3647已经不能满足UTMState Plane等投影坐标系的要求,ArcGIS 9.2存储的数据可以拥有更高精度的空间参考。

    默认情况下,ArcGIS 9.2为整数坐标采用53位空间存储,当然在编辑没有升级空间参考的空间数据库中的数据时,也可以保持向下兼容。新的COM接口已经可以用来判断数据采用的是低精度的各种空间参考,还是高精度的,同时有新的接口可以在低精度空间参考和高精度空间参考之间转换。

    还是默认情况下,Tolerance=10*resolutionminimum tolerance=2*resolution=2.0/scale factortolerance决定在relationaltopological操作中,两个坐标之间的最小距离,当小于该距离时,认为这两个坐标为相同的坐标。relationaltopological操作采用不同的tolerance会得到不同的处理结果。9.2之前tolerance值受resolution的影响,9.2中必须要明确指定tolerance的值,在IRelationalOperatorITopologicalOperator等对两个几何对象进行Geometry操作的接口中,使用第一个对象的tolerance来判断两几何体点点之间的关系,如果空间参考是未定义,或没有空间参考和几何体关联,将采用该格网所允许的最小tolerance取值。

 //使用SpatialReferenceEnvironment

private void PrintPreDefinedProjections()

{

    ISpatialReferenceFactory spatialReferenceFactory = new SpatialReferenceEnvironmentClass();

    ISet projectionSet = spatialReferenceFactory.CreatePredefinedProjections();

    System.Windows.Forms.MessageBox.Show("Number of predefined Projections = " + projectionSet.Count);

    projectionSet.Reset();

    for (int i = 0; i < projectionSet.Count; i++)

     {

        IProjection projection = projectionSet.Next() as IProjection;

        System.Windows.Forms.MessageBox.Show(projection.Name);

    }

}

    //CreatePredefinedProjections返回AE中所有预定义的投影坐标,一共59个。ISpatialReferenceFactoryCreateESRISpatialReferenceFromPRJFile方法可以从已定义的PRJ文件获取坐标。

private IProjectedCoordinateSystem LoadProjectedCoordinateSystem()

{

    ISpatialReferenceFactory spatialReferenceFactory = new SpatialReferenceEnvironmentClass();

    IProjectedCoordinateSystem projectedCoordinateSystem = spatialReferenceFactory.CreateESRISpatialReferenceFromPRJFile("C:\\Program Files\\ArcGIS\\Coordinate Systems\\Projected Coordinate Systems\\World\\Mollweide (world).prj"as IProjectedCoordinateSystem;

    return projectedCoordinateSystem;

 }

 

除了ISpatialReferenceFactory接口,AE还提供ISpatialReferenceFactory3接口实现了创建垂直坐标系、构建高精度坐标系和低精度坐标系的系列方法。

private void Constr tCoordinateSystem(bool highPrecision)

{

    ISpatialReferenceFactory3 spatialReferenceFactory = new SpatialReferenceEnvironmentClass();

    ISpatialReference3 spatialReference = spatialReferenceFactory.CreateESRISpatialReferenceFromPRJFile("D:\\ArcGIS\\Coordinate Systems\\Geographic Coordinate Systems\\World\\WGS 1984.prj") as ISpatialReference3;

    IControlPrecision2 controlPrecision = spatialReference as IControlPrecision2;

    //Determines whether you are constr ting a high or low.

    controlPrecision.IsHighPrecision = highPrecision;

    ISpatialReferenceResolution spatialReferenceResolution = spatialReference as ISpatialReferenceResolution;

    //These three methods are the keys, constr t horizon, then set the default x,y resolution and tolerance.

    spatialReferenceResolution.Constr tFromHorizon();

    //Set the default x,y resolution val.

    spatialReferenceResolution.SetDefaultXYResolution();

    //Set the default x,y tolerance val.

    ISpatialReferenceTolerance spatialReferenceTolerance = spatialReference as ISpatialReferenceTolerance;

    spatialReferenceTolerance.SetDefaultXYTolerance();

    do le xMin;

    do le xMax;

    do le yMin;

    do le yMax;

    spatialReference.GetDomain(out xMin, out xMax, out yMin, out yMax);

    System.Windows.Forms.MessageBox.Show("Domain : " + xMin + ", " + xMax + ", " + yMin + ", " + yMax);

}

 

    IControlPrecision2.IsHighPrecision用来判断是否对数据采用高精度坐标,后面的设置空间参考的方法将根据这个判断来决定各种参数的精确程度。highPrecision等于trfalse时,返回的Domain分别是:

    highPrecision=tr   -400 9006799.25474099    -400 9006799.25474099

    highPrecision=false  -400 793.04646944444426 -400 793.04646944444426

    可以看出两者之间精度差别的大小。

 

我们可以创建一个新的投影坐标系并保存为prj文件,同时可以利用这个prj生成一个新的投影坐标系。

private void ImportExportSR_Example()

{

    //Instantiate a predefined spatial reference and set its coordinate grid information.

    ISpatialReferenceFactory spatialReferenceFactory = new SpatialReferenceEnvironmentClass();

    IProjectedCoordinateSystem projectedCoordinateSystem = spatialReferenceFactory.CreateProjectedCoordinateSystem((int)esriSRProjCSType.esriSRProjCS_WGS1984UTM_10N);

    ISpatialReferenceResolution spatialReferenceResolution = projectedCoordinateSystem as ISpatialReferenceResolution;

    ISpatialReferenceTolerance spatialReferenceTolerance = projectedCoordinateSystem as ISpatialReferenceTolerance;

    spatialReferenceResolution.Constr tFromHorizon();

    spatialReferenceTolerance.SetDefaultXYTolerance();

    //Export the PCS to a .prj file.

    String fileName = "c:\\temp\\utm10.prj";

    spatialReferenceFactory.ExportESRISpatialReferenceToPRJFile(fileName, projectedCoordinateSystem);

    //Rehydrate it as a new spatial reference object.

    ISpatialReference projectedCoordinateSystem2 = spatialReferenceFactory.CreateESRISpatialReferenceFromPRJFile(fileName);

    //See if they are eq l.

    IClone comparison = projectedCoordinateSystem as IClone;

    //Should be tr, but coordinate grid information has not been checked.

    System.Windows.Forms.MessageBox.Show((comparison.IsEq l(projectedCoordinateSystem2 as IClone)).ToString());

    ISpatialReference2 comparePrecisions = projectedCoordinateSystem as ISpatialReference2;

    //Should be false, PRJ files do not persist coordinate grid information.

    System.Windows.Forms.MessageBox.Show((comparePrecisions.IsXYPrecisionEq l(projectedCoordinateSystem2)).ToString());

}

 

转载于:https://www.cnblogs.com/flyingliang-gis/archive/2010/06/24/1764635.html

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值