MATLAB nlyfit,Model transmission line

Main

Model type — Model type of transmission line

Delay-based and lossless (default) | Delay-based and lossy | Lumped parameter L-section | Lumped parameter Pi-section | Coaxial | Coplanar waveguide | Microstrip | Two-wire | Parallel-plate | Equation-based | RLCG

Model type of the transmission line, specified as one of the following:

Delay-based and lossless – transmission

line is delay-based but no loss.

Delay-based and lossy – transmission line

is delay-based and there is loss.

Lumped parameter L-section – transmission

line as a number of RLGC L-sections.

2b74a9ce8ce0052fbc4754b9049f8ed0.png

Lumped parameter Pi-section – transmission

line as a number of RLGC pi-sections.

dec34802fc01993eb1018df49493bb5e.png

Coaxial – transmission line as a coaxial

transmission line. A coaxial transmission line is shown in

cross-section in the following figure. Its physical

characteristics include the radius of the inner conductor,

a, and the radius of the outer conductor

b.

848c50932604a08f95f296b906cb1ea2.gif

Coplanar waveguide – transmission line as a

coplanar waveguide. A coplanar waveguide transmission line is

shown in cross-section in the following figure. Its physical

characteristics include the conductor width,

w, the conductor thickness,

t, the slot width, s,

the substrate height, d, and the relative

permittivity constant, ε.

f526270aaaae28cca8e069541d61f3c7.gif

Microstrip – transmission line as a

microstrip transmission line. A microstrip transmission line is

shown in cross-section in the following figure. Its physical

characteristics include the microstrip width,

w, the microstrip thickness,

t, the substrate height,

d, and the relative permittivity

constant, ε.

b024a7bc75f7994f196ba08b860d99ca.gif

Two-wire – transmission line as two-wire

transmission line. A two-wire transmission line is shown in

cross-section in the following figure. Its physical

characteristics include the radius of the wires,

a, the separation or physical distance

between the wire centers, S, and the

relative permittivity and permeability of the wires References. RF Blockset™ Equivalent Baseband software assumes the relative

permittivity and permeability are uniform.

b576a2b9893904c57ace6b42873e8eb5.png

Parallel plate –

transmission line as a parallel-plate transmission line. A

parallel-plate transmission line is shown in cross-section in

the following figure. Its physical characteristics include the

plate width, w, and the plate separation,

d. References.

921c958f44aa0b03ada8e7752a5dcb55.gif

Equation based –

transmission line as an equation-based transmission line. The

transmission line, which can be lossy or lossless, is treated as

a two-port linear network.

RLCG –

transmission line as an RLCG transmission line. This line is

described in the block dialog box in terms of its

frequency-dependent resistance, inductance, capacitance, and

conductance. The transmission line, which can be lossy or

lossless, is treated as a two-port linear network.

da4bda56b28ebed10c7fd86783ceacbb.png

Transmission delay — Delay in transmission line

4.7e-9 s (default) | real scalar

Delay in the transmission line, specified as a real scalar in

s, milliseconds, microseconds, or nanoseconds.

To enable this parameter, choose one of the following:

Delay-based and lossless in

Model type.

Delay-based and lossy in

Model type.

Characteristic impedance — Impedance of transmission line

50 Ohm (default) | real scalar

Impedance of the transmission line, specified as a real scalar in

Ohm, kOhm,

MOhm, or GOhm.

Dependencies

To enable this parameter, choose one of the following:

Delay-based and lossless,

Delay-based and lossy, or

Equation-based in

Model type.

Lumped parameter L-section or

Lumped parameter Pi-section

in Model type and By

characterisitc impedance and capacitance in

Parameterization.

Resistance per unit length — Resistance per unit length of transmission line

0.3 Ohm/m (default) | positive scalar

Resistance per unit length of the transmission line, specified as a

positive scalar in Ohm/m, kOhm/m,

MOhm/m, or GOhm/m.

Dependencies

To enable this parameter, choose one of the following:

Delay-based and lossy or

RLCG in Model

type.

Lumped parameter L-section or

Lumped parameter Pi-section

in Model type and By

characterisitc impedance and capacitance in

Parameterization.

Line length — Physical length of transmission line

1 cm (default) | positive scalar

Physical length of the transmission line or l,

specified as a positive scalar in m,

cm, mm, um,

in, or ft.

Dependencies

To enable this parameter, choose one of the following:

Delay-based and lossy,

Coaxial,

Coplanar waveguide,

Microstrip, or

Two-wire,

Parallel-plate,

Equation-based, or

RLCG in Model

type.

Lumped parameter L-section or

Lumped parameter Pi-section

in Model type and By

characterisitc impedance and capacitance or

By inductance and capacitance in

Parameterization.

Number of segments — Number of segments in transmission line

10 (default) | positive scalar

Number of segments in the transmission line, specified as a positive

scalar.

Dependencies

To enable this parameter, choose one of the following:

Delay-based and lossy in

Model type.

Lumped parameter L-section or

Lumped parameter Pi-section

in Model type and By

characterisitc impedance and capacitance or

By inductance and capacitance in

Parameterization.

Parameterization — Type of parameters to model segments in transmission line

By characterisitc impedance and

capacitance (default) | By inductance and capacitance

Type of parameters to model segments in transmission line, specified as

By characterisitc impedance and capacitance or

By inductance and capacitance.

Dependencies

To enable this parameter, select Lumped parameter

L-section or Lumped parameter

Pi-section in Model type.

Capacitance per unit length — Capacitance per unit length of transmission line

94e-12 F/m (default) | positive scalar

Capacitance per unit length of the transmission line, specified as a

positive scalar in F/m, mF/m,

uF/m, nF/m, or

pF/m.

Dependencies

To enable this parameter, choose Lumped parameter

L-section, Lumped parameter

Pi-section, or RLCG in

Model type.

Conductance per unit length — Conductance per unit length of transmission line

5e-6 S/m (default) | positive scalar

Conductance per unit length of the transmission line, specified as a

positive scalar in S/m, mS/m,

uS/m, or nS/m.

Dependencies

To enable this parameter, choose Lumped parameter

L-section, Lumped parameter

Pi-section, or RLCG in

Model type.

Inductance per unit length — Inductance per unit length of transmission line

235e-9 H/m (default) | positive scalar

Inductance per unit length of the transmission line, specified as a

positive scalar in H/m, mH/m,

uH/m, or nH/m.

Dependencies

To enable this parameter, choose one of the following:

Lumped parameter L-section, or

Lumped parameter Pi-section

in Model type and By

inductance and capacitance in

Parameterization.

RLCG in Model

type

Outer radius — Outer radius of coaxial transmission line

2.57 mm (default) | positive scalar

Outer radius of coaxial transmission line, specified as a positive scalar

in m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Coaxial in

Model type.

Inner radius — Inner radius of coaxial transmission line

2.57 mm (default) | positive scalar

Inner radius of coaxial transmission line, specified as a positive scalar

in m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Coaxial in

Model type.

Relative permeability constant — Relative permeability of dielectric

1 (default) | scalar

Relative permeability of the dielectric, specified as a scalar.

Dependencies

To enable this parameter, choose Coaxial,

Two-wire, or

Parallel-plate in Model

type.

Relative permittivity constant — Relative permittivity of dielectric

2.2 (default) | scalar

Relative permittivity of the dielectric, specified as a scalar.

Dependencies

To enable this parameter, choose Coaxial,

Coplanar waveguide,

Microstrip,

Two-wire, or

Parallel-plate in Model

type.

Loss Tangent of dielectric — Loss angle tangent of dielectric

0 (default) | scalar

Loss angle tangent of the dielectric, specified as a scalar.

Dependencies

To enable this parameter, choose Coaxial,

Coplanar waveguide,

Microstrip,

Two-wire, or

Parallel-plate in Model

type.

Conductivity of conductor — Conductivity of conductor

inf (default) | scalar

Conductivity of conductor, specified as a scalar in

S/m, mS/m, uS/m, or

nS/m.

Dependencies

To enable this parameter, choose Coaxial,

Coplanar waveguide,

Microstrip,

Two-wire or

Parallel-plate in Model

type.

Stub mode — Type of stub

Not a stub (default) | Shunt | Series

Type of stub, specified as Not a stub,

Shunt, or Series.

See Parameter Calculations for Transmission Line with Stub.

Dependencies

To enable this parameter, choose Coaxial,

Coplanar waveguide,

Microstrip

Two-wire,

Parallel-plate,

Equation-based, or

RLCG in Model

type.

Termination of stub — Type of termination for stub

Open (default) | Short

Type of termination for stub, specified as Open

or Short.

Dependencies

To enable this parameter, choose Series or

Shunt in Stub

mode.

Conductor width — Physical width of conductor

0.6 mm (default) | positive scalar

Physical width of the conductor, specified as a positive scalar in

m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Coplanar

waveguide in Model type.

Slot width — Physical width of slot

0.2 mm (default) | positive scalar

Physical width of the slot, specified as a positive scalar in

m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Coplanar

waveguide in Model type.

Substrate height — Thickness of dielectric on which conductor resides

0.635 mm (default) | positive scalar

Thickness of the dielectric on which the conductor resides, specified as a

positive scalar in m, cm,

mm, um, in, or

ft.

Dependencies

To enable this parameter, choose Coplanar

waveguide or Microstrip in

Model type.

Strip thickness — Physical thickness of conductor

5 um (default) | positive scalar

Physical thickness of the conductor, specified as a positive scalar in

m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Coplanar

waveguide or Microstrip in

Model type.

Strip Width — Width of microstrip transmission line

0.6 mm (default) | positive scalar

Width of microstrip transmission line, specified as a positive scalar in

m, cm, mm,

um, in, or

ft.

Dependencies

To enable this parameter, choose Microstrip

in Model type.

Wire radius — Radius of conducting wires of two-wire transmission line

0.67 mm (default) | positive scalar

Radius of the conducting wires of the two-wire transmission line,

specified as a positive scalar in m,

cm, mm, um,

in, or ft.

Dependencies

To enable this parameter, choose Two-wire

in Model type.

Wire separation — Physical distance between conducting wires of two-wire transmission line

1.62 mm (default) | positive scalar

Physical distance between the conducting wires of the two-wire

transmission line, specified as a positive scalar in m,

cm, mm, um,

in, or ft.

Dependencies

To enable this parameter, choose Two-wire

in Model type.

Plate width — Width of parallel-plate transmission line

5 mm (default) | positive scalar

Width of the parallel-plate transmission line, specified as a positive

scalar in m, cm,

mm, um, in, or

ft.

Dependencies

To enable this parameter, choose

Parallel-plate in Model

type.

Plate separation — Thickness of dielectric separating plates

1 mm (default) | positive scalar

Thickness of the dielectric separating the plates, specified as a positive

scalar in m, cm,

mm, um, in, or

ft.

Dependencies

To enable this parameter, choose

Parallel-plate in Model

type.

Phase velocity (m/s) — Propagation velocity of a uniform plane wave on transmission line

299792458 (default) | positive scalar

Propagation velocity of a uniform plane wave on the transmission line,

specified as a positive scalar in meters per second

Dependencies

To enable this parameter, choose

Equation-based in Model

type.

Loss (dB/m) — Reduction in strength of signal as it travels over transmission line

0 (default) | positive scalar

Reduction in strength of the signal as it travels over the transmission

line, specified as a positive scalar in meters per second

Dependencies

To enable this parameter, choose

Equation-based in Model

type.

Frequency — Modeling frequencies

1e9 (default) | positive scalar

Modeling frequencies, specified as a positive scalar or vector in

Hz, kHz,

MHz, or

GHz.

Dependencies

To enable this parameter, choose

Equation-based or

RLCG in Model

type.

Interpolation method — Interpolation method used to calculate values at the modeling frequencies

Linear (default) | Spline | Cubic

Interpolation method used to calculate the values at the modeling

frequencies, specified as Linear,

Spline, or

Cubic.

Dependencies

To enable this parameter, choose

Equation-based or

RLCG in Model

type.

Ground and hide negative terminals — Ground RF circuit terminals

on (default) | off

Select this parameter to internally ground and hide the negative

terminals. To expose the negative terminals, clear this parameter. By

exposing these terminals, you can connect them to other parts of your model.

By default, this option is selected.

Note

Modeling options tab is activated for all transmission line options except

Delay-based and lossless, Delay-based

and lossy, Lumped parameter L-section,

and Lumped parameter pi-section.Modeling

Modeling Options — Options to model S-parameters

Frequency domain (default) | Time domain (rationalfit)

Options to model S-parameters, specified as:

Frequency domain – Computes the baseband

impulse response for each carrier frequency independently. This technique is

based on convolution. There is an option to specify the duration of the

impulse response. For more information, see Compare Time and Frequency Domain Simulation Options for S-parameters.

Time domain (rationalfit) – Computes the

analytical rational model that approximates the whole range of the

data.

For the Amplifier and S-parameters blocks, the default

value is Time domain (rationalfit). For the

Transmission Line block, the default value is Frequency

domain.

Automatically estimate impulse response duration — Calculate impulse response duration automatically

off (default) | on

Select Automatically estimate impulse response duration to

calculate impulse response duration automatically. Clear the selection to specify

impulse response duration.

Dependencies

To enable this parameter, choose Frequency domain in

Modeling options.

Impulse response duration — Manually specify impulse response duration

0 s (default) | positive scalar

Manually specify impulse response duration, specified as a positive scalar in

s, ms,

us, or ns.

Dependencies

To enable this parameter, clear Automatically estimate impulse response

duration.

Fitting options — Fitting options for rationalfit

Share all poles (default) | Share poles by columns | Fit individually

Fitting options for rationalfit, specified as Share all

poles, Share poles by columns, or

Fit individually.

For the Amplifier block, the default value is Fit

individually. For the S-parameters block and

Transmission Line block, the default value is Share all

poles.

Dependencies

To enable this parameter, choose Time domain

(rationalfit) in Modeling options.

Relative error desired (dB) — Relative error acceptable in rationalfit output

-40 (default) | real scalar

Relative error acceptable in rationalfit output, specified as a real scalar in

decibels.

Dependencies

To enable this parameter, choose Time domain

(rationalfit) in Modeling options.

Rational fitting results — Values of rationalfit calculations

read-only (default)

Shows values of Number of independent fits, Number of

required poles, and Relative error achieved

(dB).

When modeling using Time domain, the Plot in

Visualization tab plots the data defined in Data

Source and the values in the rationalfit

function.

Dependencies

To enable this parameter, choose Time domain

(rationalfit) in Modeling options.