环境:<?xml:namespace prefix = o ns = "urn:schemas-microsoft-com:office:office" />

7133存储一台,连接IBM小型机,16块盘,无热备,34块盘做RAID5,第44块盘做RAID10

 

故障描述:

其中2RAID5各坏一块盘

 

处理:

分别更换故障盘

 

更换步骤:

1、查看RAID的状态

# smitty ssaraid

=> List All Defined SSA RAID Arrays

<?xml:namespace prefix = v ns = "urn:schemas-microsoft-com:vml" />

其中hdisk6hdisk7状态降级,说明有硬盘故障

 

2、用lsdev Cc pdisk查看现在硬盘的编号、槽位,做好记录

 

3、用smitty ssadlog 命令查看pdiskhdisk的对应关系

 

=> Show Logical to Physical SSA Disk Relationship

 

4、记录需更换硬盘的pdiskhdisk、槽位等信息

 

说明pdisk0pdisk5被踢出

 

 

5、停应用 

 

6、删除RAID中需要更换的pdisk

# smitty ssaraid

=> Change Member Disks in an SSA RAID Array

=> Remove a Disk From an SSA RAID Array

=> 选对应的hdisk

=> Disk to Remove项中选坏的pdisk

如果硬盘被踢出RAID,此步骤选不了hdisk,可省略

 

7、用diag 将坏pdisk设为service mode状态

=> Task Selection

=> SSA Service Aids

=> set Service mode

这时故障硬盘闪黄灯

 

8、 拔掉坏盘 

9、将新硬盘插入此槽位 

10、在SET SERVICE MODE界面中按回车RESET

 

 

 

11#rmdev -dl 坏的pdisk 

12#cfgmgr -l ssar 

13、用lsdev Cc pdisk查看新硬盘的编号、槽位,做好记录

 

 

14# smitty ssaraid ,将新pdisk设为RAID候选盘

=> Change/Show Use of an SSA Physical Disk

=> 选合适的SSA

=> 选新pdisk

=> Current Use项改为Array Candidate Disk

 

 

 

15 # smitty ssaraid ,将新pdisk加如RAID

=> Change Member Disks in an SSA RAID Array

=> Add a Disk to an SSA RAID Array

=> 选对应的hdisk

=> Disk to add项中选新的pdisk

 

使用相同方法更换其他故障盘

 

16、查看同步情况:

 

 

17、如果没有起应用,起应用