Cisco 3550-SMI IOS升级过程分享

 配置C3550的管理地址

配置管理地址的目的是方便把设备上现有的IOS备份出去以及把新的IOS传到3550FLASH上来
Switch>enable
Switch#conf t
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)#int vlan 1
Switch(config-if)#ip add 10.1.27.240 255.255.255.0
Switch(config-if)#exit
Switch(config)#ip default-gateway 10.1.27.254
Switch(config)#^Z
Switch#show ip int bri
Interface                  IP-Address      OK? Method Status                Protocol
VLAN1                      10.1.27.240     YES NVRAM  up                    up     
FastEthernet0/1            unassigned      YES unset  down                  down   
FastEthernet0/2            unassigned      YES unset  down                  down   
FastEthernet0/3            unassigned      YES unset  down                  down   
FastEthernet0/4            unassigned      YES unset  down                  down   
FastEthernet0/5            unassigned      YES unset  down                  down   
FastEthernet0/6            unassigned      YES unset  down                  down   
FastEthernet0/7            unassigned      YES unset  down                  down   
FastEthernet0/8            unassigned      YES unset  down                  down   
FastEthernet0/9            unassigned      YES unset  down                  down   
FastEthernet0/10           unassigned      YES unset  down                  down   
FastEthernet0/11           unassigned      YES unset  down                  down   
FastEthernet0/12           unassigned      YES unset  down                  down   
FastEthernet0/13           unassigned      YES unset  down                  down   
FastEthernet0/14           unassigned      YES unset  down                  down   
FastEthernet0/15           unassigned      YES unset  down                  down   
FastEthernet0/16           unassigned      YES unset  down                  down   
FastEthernet0/17           unassigned      YES unset  down                  down   
FastEthernet0/18           unassigned      YES unset  down                  down   
FastEthernet0/19           unassigned      YES unset  down                  down   
FastEthernet0/20           unassigned      YES unset  down                  down   
FastEthernet0/21           unassigned      YES unset  down                  down   
FastEthernet0/22           unassigned      YES unset  down                  down   
FastEthernet0/23           unassigned      YES unset  down                  down   
FastEthernet0/24           unassigned      YES unset  up                    up     
GigabitEthernet0/1         unassigned      YES unset  down                  down   
GigabitEthernet0/2         unassigned      YES unset  down                  down   
Switch#ping 10.1.27.59
Type escape sequence to abort.
Sending 5, 100-byte ICMP Echos to 10.1.27.59, timeout is 2 seconds:
!!!!!
Success rate is 100 percent (5/5), round-trip min/avg/max = 1/2/3 ms
Switch#

二备份现有的IOS和配置

PC机上运行TFTPserver,把设备当前运行的IOS和配置文件上传到PC机上。
Switch#dir
Directory of flash:/
  2  -rwx     1645807   Mar 01 1993 01:10:52  c3500XL-c3h2s-mz-120.5.2-XU.bin
  3  -rwx         305   Mar 01 1993 00:28:01  env_vars
  4  drwx        6784   Jul 18 2000 01:47:41  html
111  -rwx        1367   Mar 01 1993 00:51:00  01
112  -rwx         600   Mar 01 1993 00:01:52  vlan.dat
114  -rwx        1125   Mar 01 1993 00:05:10  config.text
3612672 bytes total (937472 bytes free)
Switch#copy flash tftp
Source filename []? c3500XL-c3h2s-mz-120.5.2-XU.bin
Address or name of remote host []? 10.1.27.59
Destination filename [c3500XL-c3h2s-mz-120.5.2-XU.bin]?
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
1645807 bytes copied in 12.79 secs (137150 bytes/sec)
Switch#

 删除设备上现有的IOS

由于考虑到设备的硬件flash大小不够,所以要把现有的IOS删除掉,以便新的IOS顺利上传到flash上来。
Switch#delete c3500XL-c3h2s-mz-120.5.2-XU.bin
Delete filename [c3500XL-c3h2s-mz-120.5.2-XU.bin]?
Delete flash:c3500XL-c3h2s-mz-120.5.2-XU.bin? [confirm]
Switch#dir
Directory of flash:/
  3  -rwx         305   Mar 01 1993 00:28:01  env_vars
  4  drwx        6784   Jul 18 2000 01:47:41  html
111  -rwx        1367   Mar 01 1993 00:51:00  01
112  -rwx         600   Mar 01 1993 00:01:52  vlan.dat
114  -rwx        1125   Mar 01 1993 00:05:10  config.text
 
3612672 bytes total (2584064 bytes free)
Switch#

四上传新的IOSflash

把新的IOS放在TFTP serverroot目录下
Switch#dir  
Directory of flash:/
 
  3  -rwx         305   Mar 01 1993 00:28:01  env_vars
  4  drwx        6784   Jul 18 2000 01:47:41  html
111  -rwx        1367   Mar 01 1993 00:51:00  01
112  -rwx         600   Mar 01 1993 00:01:52  vlan.dat
114  -rwx        1125   Mar 01 1993 00:05:10  config.text
 
3612672 bytes total (2584064 bytes free)
Switch#copy tftp flash
Address or name of remote host [10.1.27.59]?
Source filename [c3500XL-c3h2s-mz-120.5.2-XU.bin]? c3550-smi.bin
Destination filename [c3550-smi.bin]?
Accessing tftp://10.1.27.59/c3550-smi.bin...
Loading c3550-smi.bin from 10.1.27.59 (via VLAN1): !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
[OK - 1645807 bytes]
 
1645807 bytes copied in 48.334 secs (34287 bytes/sec)
Switch#dir
Directory of flash:/
 
  2  -rwx     1645807   Mar 01 1993 00:18:31  c3550-smi.bin
  3  -rwx         305   Mar 01 1993 00:28:01  env_vars
  4  drwx        6784   Jul 18 2000 01:47:41  html
111  -rwx        1367   Mar 01 1993 00:51:00  01
112  -rwx         600   Mar 01 1993 00:01:52  vlan.dat
114  -rwx        1125   Mar 01 1993 00:05:10  config.text
 
3612672 bytes total (937472 bytes free)
Switch#

五更改设备启动引导文件

更改设备的系统引导文件,以便设备正常从新的IOS启动。
Switch#show boot
BOOT path-list:      flash:c3500XL-c3h2s-mz-120.5.2-XU.bin
Config file:          flash:config.text
Enable Break:        no
Manual Boot:         no
HELPER path-list:   
NVRAM/Config file  buffer size:   32768
Switch#conf t
Enter configuration commands, one per line.  End with CNTL/Z.
Switch(config)#boot system flash:c3550-smi.bin
Switch(config)#^Z
Switch#wr
00:20:41: %SYS-5-CONFIG_I: Configured from console by console
Switch#show boot
BOOT path-list:      flash:c3550-smi.bin
Config file:         flash:config.text
Enable Break:        no
Manual Boot:         no
HELPER path-list:   
NVRAM/Config file
      buffer size:   32768
Switch#

六重新启动查看是否升级成功

Cisco-3550-SMI#reload
Proceed with reload? [confirm]
 
00:05:32: %SYS-5-RELOAD: Reload requested
 
C3500XL Boot Loader (C3500-HBOOT-M) Version 12.0(5.2)XU, MAINTENANCE INTERIM SOFTWARE
Compiled Mon 17-Jul-00 18:42 by ayounes
 starting...
Base ethernet MAC Address: 00:04:4d:72:87:c0
Xmodem file system is available.
Initializing Flash...
flashfs[0]: 110 files, 3 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 3612672
flashfs[0]: Bytes used: 2675712
flashfs[0]: Bytes available: 936960
flashfs[0]: flashfs fsck took 3 seconds.
...done Initializing Flash.
Boot Sector Filesystem (bs:) installed, fsid: 3
Parameter Block Filesystem (pb:) installed, fsid: 4
Loading "flash:c3550-smi.bin"...###########################################################################################################################################################
 
File "flash:c3550-smi.bin" uncompressed and installed, entry point: 0x3000
executing...
 
              Restricted Rights Legend
 
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
 
           cisco Systems, Inc.
           170 West Tasman Drive
           San Jose, California 95134-1706
 
 
 
Cisco Internetwork Operating System Software
IOS (tm) C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5.2)XU, MAINTENANCE INTERIM SOFTWARE
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Mon 17-Jul-00 18:29 by ayounes
Image text-base: 0x00003000, data-base: 0x00301F3C
 
 
Initializing C3500XL flash...
flashfs[1]: 110 files, 3 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 3612672
flashfs[1]: Bytes used: 2675712
flashfs[1]: Bytes available: 936960
flashfs[1]: flashfs fsck took 4 seconds.
flashfs[1]: Initialization complete.
...done Initializing C3500XL flash.
C3500XL POST: System Board Test: Passed
C3500XL POST: Daughter Card Test: Passed
C3500XL POST: CPU Buffer Test: Passed
C3500XL POST: CPU Notify RAM Test: Passed
C3500XL POST: CPU Interface Test: Passed
C3500XL POST: Testing Switch Core: Passed
C3500XL POST: Testing Buffer Table: Passed
C3500XL POST: Data Buffer Test: Passed
C3500XL POST: Configuring Switch Parameters: Passed
C3500XL POST: Ethernet Controller Test: Passed
C3500XL POST FAILURE: front-end post: FastEthernet0/9:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/10:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/11:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/12:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/13:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST: MII Test: Passed
cisco WS-C3524-XL (PowerPC403) processor (revision 0x01) with 8192K/1024K bytes of memory.
Processor board ID FAA0446W0XD, with hardware revision 0x00
Last reset from warm-reset
 
Processor is running Enterprise Edition Software
Cluster command switch capable
Cluster member switch capable
19 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)
 
32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:04:4D:72:87:C0
Motherboard assembly number: 73-3904-11
Power supply part number: 34-0851-02
Motherboard serial number: FAB0445F1YR
Power supply serial number: NONE
Model revision number: A0
Model number: WS-C3524-XL-EN
System serial number: FAA0446W0XD
 
 
Press RETURN to get started!

七注意事项:

1路径和目标文件不一致问题

在升级过程中一定要小心,在敲命令行的时候特别要仔细,特别是在改启动路径的时候,如果启动路径的文件和flash里面的IOS不相同的话,是启动不了。解决方案

 switch模式下,查看系统启动路径的全称

Interrupt within 5 seconds to abort boot process.
Boot process failed...
The system is unable to boot automatically.  The BOOT
environment variable needs to be set to a bootable
image.
switch: set
ASSEMBLY_REVISION_NUM=B0
BOOT=flash:c3550-smi.bin
MAC_ADDR=00:04:4D:72:87:C0
MODEL_NUM=WS-C3524-XL-EN
MODEL_REVISION_NUM=A0
MOTHERBOARD_ASSEMBLY_NUM=73-3904-11
MOTHERBOARD_SERIAL_NUM=FAB0445F1YR
POWER_SUPPLY_PART_NUM=34-0851-02
POWER_SUPPLY_SERIAL_NUM=NONE
SYSTEM_SERIAL_NUM=FAA0446W0XD
switch:

b查看flashIOS的完全名称。

switch: dir flash:
Directory of flash:/
 
2    -rwx  1645824   <date>               c35550-smi.bin
3    -rwx  1564      <date>               config.text
4    drwx  6784      <date>               html
111  -rwx  1367      <date>               01
112  -rwx  600       <date>               vlan.dat
114  -rwx  290       <date>               env_vars
 
936960 bytes available (2675712 bytes used)
switch:

cflash里面的IOS的名称改成和boot里面的一致!

switch: rename flash:c35550-smi.bin flash:c3550-smi.bin
switch:
switch:
switch: dir flash:
Directory of flash:/
 
2    -rwx  1645824   <date>               c3550-smi.bin
3    -rwx  1564      <date>               config.text
4    drwx  6784      <date>               html
111  -rwx  1367      <date>               01
112  -rwx  600       <date>               vlan.dat
114  -rwx  290       <date>               env_vars
 
936960 bytes available (2675712 bytes used)
switch:

d重启设备

switch: reset
Are you sure you want to reset the system (y/n)?y
System resetting...
 
C3500XL Boot Loader (C3500-HBOOT-M) Version 12.0(5.2)XU, MAINTENANCE INTERIM SOFTWARE
Compiled Mon 17-Jul-00 18:42 by ayounes
 starting...
Base ethernet MAC Address: 00:04:4d:72:87:c0
Xmodem file system is available.
Initializing Flash...
flashfs[0]: 110 files, 3 directories
flashfs[0]: 0 orphaned files, 0 orphaned directories
flashfs[0]: Total bytes: 3612672
flashfs[0]: Bytes used: 2675712
flashfs[0]: Bytes available: 936960
flashfs[0]: flashfs fsck took 3 seconds.
...done Initializing Flash.
Boot Sector Filesystem (bs:) installed, fsid: 3
Parameter Block Filesystem (pb:) installed, fsid: 4
Loading "flash:c3550-smi.bin"...###########################################################################################################################################################
 
File "flash:c3550-smi.bin" uncompressed and installed, entry point: 0x3000
executing...
 
              Restricted Rights Legend
 
Use, duplication, or disclosure by the Government is
subject to restrictions as set forth in subparagraph
(c) of the Commercial Computer Software - Restricted
Rights clause at FAR sec. 52.227-19 and subparagraph
(c) (1) (ii) of the Rights in Technical Data and Computer
Software clause at DFARS sec. 252.227-7013.
 
           cisco Systems, Inc.
           170 West Tasman Drive
           San Jose, California 95134-1706
 
 
 
Cisco Internetwork Operating System Software
IOS (tm) C3500XL Software (C3500XL-C3H2S-M), Version 12.0(5.2)XU, MAINTENANCE INTERIM SOFTWARE
Copyright (c) 1986-2000 by cisco Systems, Inc.
Compiled Mon 17-Jul-00 18:29 by ayounes
Image text-base: 0x00003000, data-base: 0x00301F3C
Initializing C3500XL flash...
flashfs[1]: 110 files, 3 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 3612672
flashfs[1]: Bytes used: 2675712
flashfs[1]: Bytes available: 936960
flashfs[1]: flashfs fsck took 4 seconds.
flashfs[1]: Initialization complete.
...done Initializing C3500XL flash.
C3500XL POST: System Board Test: Passed
C3500XL POST: Daughter Card Test: Passed
C3500XL POST: CPU Buffer Test: Passed
C3500XL POST: CPU Notify RAM Test: Passed
C3500XL POST: CPU Interface Test: Passed
C3500XL POST: Testing Switch Core: Passed
C3500XL POST: Testing Buffer Table: Passed
C3500XL POST: Data Buffer Test: Passed
C3500XL POST: Configuring Switch Parameters: Passed
C3500XL POST: Ethernet Controller Test: Passed
C3500XL POST FAILURE: front-end post: FastEthernet0/9:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/10:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/11:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/12:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST FAILURE: front-end post: FastEthernet0/13:
C3500XL POST FAILURE: looped-back packet not received
C3500XL POST: MII Test: Passed
cisco WS-C3524-XL (PowerPC403) processor (revision 0x01) with 8192K/1024K bytes of memory.
Processor board ID FAA0446W0XD, with hardware revision 0x00
Last reset from power-on
 
Processor is running Enterprise Edition Software
Cluster command switch capable
Cluster member switch capable
19 FastEthernet/IEEE 802.3 interface(s)
2 Gigabit Ethernet/IEEE 802.3 interface(s)
 
32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:04:4D:72:87:C0
Motherboard assembly number: 73-3904-11
Power supply part number: 34-0851-02
Motherboard serial number: FAB0445F1YR
Power supply serial number: NONE
Model revision number: A0
Model number: WS-C3524-XL-EN
System serial number: FAA0446W0XD
Press RETURN to get started!

2IOS损坏或者其他导致IOS损坏不能正常启动

如果在升级过程中出现断电或者其他原因导致IOS没有完全写入flash中,但是flash中的旧的IOS又被删除掉了,解决方案

a只能采用超级终端用Xmodem来把IOS传到设备

只能采用超级终端用Xmodem来把IOS传到设备里面去,超级终端的设置采用默认设置就好了。
Bswitch模式下执行采用xmodem
(很长时间,我试过39分钟)
 

c重启设备

传完后,重新启动就ok啦。

3启动路径不完全,导致设备不能正常启动

在升级过程中的最后一步,修改启动路径的时候,把路径写错了,比如我们今天就是这样的把本来正确的是boot system flash:c3550-smi.bin结果写成了boot  system c3550-smi.bin导致设备不能正常启动。解决方案

 aset命令看设备当前运行的路径

switch: set
ASSEMBLY_REVISION_NUM=B0
BOOT=c3550-smi.bin
MAC_ADDR=00:04:4D:72:87:C0
MODEL_NUM=WS-C3524-XL-EN错误!未找到图形项目表。
MODEL_REVISION_NUM=A0
MOTHERBOARD_ASSEMBLY_NUM=73-3904-11
MOTHERBOARD_SERIAL_NUM=FAB0445F1YR
POWER_SUPPLY_PART_NUM=34-0851-02
POWER_SUPPLY_SERIAL_NUM=NONE
SYSTEM_SERIAL_NUM=FAA0446W0XD
switch:

bset命令修改BOOT路径

switch: set boot flash:c3550-smi.bin
switch: set
ASSEMBLY_REVISION_NUM=B0
BOOT=flash:c3550-smi.bin
MAC_ADDR=00:04:4D:72:87:C0
MODEL_NUM=WS-C3524-XL-EN
MODEL_REVISION_NUM=A0
MOTHERBOARD_ASSEMBLY_NUM=73-3904-11
MOTHERBOARD_SERIAL_NUM=FAB0445F1YR
POWER_SUPPLY_PART_NUM=34-0851-02
POWER_SUPPLY_SERIAL_NUM=NONE
SYSTEM_SERIAL_NUM=FAA0446W0XD
switch:

c重新启动OK!









本文转自 maodou521 51CTO博客,原文链接:http://blog.51cto.com/maodou/27579,如需转载请自行联系原作者
  • 0
    点赞
  • 1
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
Cisco IOS Software, C3550 Software (C3550-IPSERVICESK9-M), Version 12.2(52)SE, RELEASE SOFTWARE (fc3) Copyright (c) 1986-2009 by Cisco Systems, Inc. Compiled Fri 25-Sep-09 09:05 by sasyamal Image text-base: 0x00003000, data-base: 0x015DB684 ROM: Bootstrap program is C3550 boot loader Switch uptime is 20 hours, 41 minutes System returned to ROM by power-on System restarted at 18:17:51 est Mon Aug 15 2011 System image file is "flash:/c3550-ipservicesk9-mz.122-52.SE/c3550-ipservicesk9-mz.122-52.SE.bin" This product contains cryptographic features and is subject to United States and local country laws governing import, export, transfer and use. Delivery of Cisco cryptographic products does not imply third-party authority to import, export, distribute or use encryption. Importers, exporters, distributors and users are responsible for compliance with U.S. and local country laws. By using this product you agree to comply with applicable laws and regulations. If you are unable to comply with U.S. and local laws, return this product immediately. A summary of U.S. laws governing Cisco cryptographic products may be found at: http://www.cisco.com/wwl/export/crypto/tool/stqrg.html If you require further assistance please contact us by sending email to export@cisco.com. Cisco WS-C3550-24 (PowerPC) processor (revision R0) with 65526K/8192K bytes of memory. Processor board ID CAT0947N3TH Last reset from warm-reset Running Layer2/3 Switching Image Ethernet-controller 1 has 12 Fast Ethernet/IEEE 802.3 interfaces Ethernet-controller 2 has 12 Fast Ethernet/IEEE 802.3 interfaces Ethernet-controller 3 has 1 Gigabit Ethernet/IEEE 802.3 interface Ethernet-controller 4 has 1 Gigabit Ethernet/IEEE 802.3 interface 24 FastEthernet interfaces 2 Gigabit Ethernet interfaces The password-recovery mechanism is enabled. 384K bytes of flash-simulated NVRAM. Base ethernet MAC Address: 00:16:46:B3:C7:80 Motherboard assembly number: 73-5700-12 Power supply part number: 34-0966-04 Motherboard serial number: CAT094809AF Power supply serial number: LIT094200U9 Model revision number: R0 Motherboard revision number: A0 Model number: WS-C3550-24-EMI System serial number: CAT0947N3TH Configuration register is 0x10F 刷完后就是EMI了。比SMI强许多,支持WEB设备管理。支持源IP防护,DAI.等安全特性,完全支持层3 SIM版好像支持不全。
CISCO WS-C3550-24-SMI 是思科(Cisco)公司生产的一款网络交换机,具有以下一些使用特点: 1. 24个端口:该交换机具有24个以太网端口,可用于连接多个设备或主机。这些端口支持自动协商功能,可以自动识别和配置连接的设备的速率和双工模式。 2. 网络管理功能:WS-C3550-24-SMI 支持 SNMP(简单网络管理协议)和 RMON(远程网络监控)等网络管理协议,使管理员能够对交换机进行监控、配置和故障排除。 3. VLAN 支持:交换机支持虚拟局域网(VLAN)技术,可以将网络划分为多个逻辑上独立的子网。这可以提高网络的安全性和性能,并方便管理。 4. 动态路由支持:WS-C3550-24-SMI 支持基于 IP 的动态路由协议,如 RIP(路由信息协议)和 OSPF(开放最短路径优先协议)。这使得交换机能够根据网络中的路由信息进行智能的数据转发。 5. 用于中小型企业:该交换机适用于中小型企业的网络环境。它提供了可靠的性能和基本的网络功能,满足了中小型网络的需求。 6. 可靠性和冗余:WS-C3550-24-SMI 支持冗余链路聚合(Link Aggregation)和热插拔模块,以提高网络的可靠性和可用性。 需要注意的是,上述特点是一般而言,实际特点可能根据具体的配置和软件版本有所不同。如果您对 WS-C3550-24-SMI 交换机有特定的需求或需要更详细的信息,建议参考思科的官方文档或咨询思科的销售代表。

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值