"Host IPMI system event log status" alarm in vCenter Server(1033725)
Symptoms
The Host Intelligent Platform Management Interface (IPMI) System Event Log (SEL) status alarm is triggered repeatedly on the ESXi/ESX host.
Acknowledging the alarm removes the exclamation on the ESXi/ESX host in the Inventory.
Note: For additional symptoms and log entries, see Additional Information section.
Purpose
When host IPMI system event log status alarm is triggered repeatedly in the Hardware Status tab in vCenter Server 4.x or 5.x, clear the IPMI System Event log file located at /var/log/ipmi.
Cause
This issue occurs when the IPMI System Event log file is full, which triggers the alarm that monitors the log file.
Resolution
To resolve this issue, ensure that the NTP settings are correct on the ESXi host, clear the IPMI System Event log file, and reset the sensors.
To clear the IPMI System Event log file and reset the sensors:
Open vCenter Server using the vSphere Client.
In the vCenter Server Inventory, select the ESXi/ESX host.
Click the Hardware Status tab.
Click System Event log under View.
Click Reset Event Log. The red alert is removed from the System Event log.
Click Reset Sensors to reset the host sensors.
Starting with ESXi 5.1 and later, you can use the localcli command line to clear the IPMI SEL logs.
To clear the IPMI SEL logs in ESXi 5.1 and later:
Connect to the ESXi host through SSH.
Run this command:
localcli hardware ipmi sel clear
If you find an incorrect date and if you are unable to reset the logs:
In ESX - Restart the management agents and sfcbd-watchdog.
To restart sfcbd-watchdog, run this command from the ESX console:
/etc/init.d/sfcbd-watchdog restartIn ESXi - Restart the management agents.
Additional Information
To determine why the log has filled up, investigate the hardware.
You experience these additional symptoms:
In the /var/log/vmkernel.log file, you see entries similar to:
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
snmpd[19956]: Connection from UDP: [10.16.16.65]:61945
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
/usr/lib/vmware/bin/vmware-hostd[19577]: Accepted password for user root from 10.16.16.65
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
snmpd[19956]: Connection from UDP: [10.16.16.65]:61945
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
sfcb-vmware_raw[5153]: IpmiIfcSelReadAll: failed call to IpmiIfcSelReadEntry cc = 0xff
Tags
IPMI System Event, Hardware warning, host ipmi system event log status, ipmi system event log is full, status of other host hardware objects alarm, esx ipmi sel unknown, host ipmi system event log status unknown
Keywords
IPMI System Event, Hardware warning
转载于:https://blog.51cto.com/arklee/1857061