奥的斯服务器显示dlm,奥的斯ACD系列电梯DLM故障的分析与处理

保时捷911车型中,配备OTIS LCB-II TCB CGE CB控制面板的电梯经常遇到0400RSL奇偶校验错误。该错误涉及电梯楼层的并行通信链路(G链路)和大厅通信链路(H链路)。当出现0400RSL故障时,需检查控制站板和终端板上的这两个通信链路,直至故障消除。恢复DLM功能需在正常状态下开关车门,测试门触点和DOL信号,确保无故障运行。

摘要生成于 C知道 ,由 DeepSeek-R1 满血版支持, 前往体验 >

Fault analysis and troubleshooting of OTIS ACD series DLM and 0400 RSL parity

It’s reported that every OTIS elevator equipped with control panel LCB-II TCBC GECB is likely to meet with the fault of 0400 RSL parity when its service life is long. The serial communication chain with a pair of G, for group control communication chain in the parallel elevator floor, would link to the outbound call and the H, for hall communication chain, would connect to the information of the certain floor. When the fault of 0400 RSL parity appears, the mentioned 2 communication chains must be checked and tested on the control station plate and the terminal plate until the fault is eliminated.

The recovery of DLM would be achieved after opening and closing the car door in the normal state and try the door contact and DOL signal. The DLM would be eliminated when it shows a trouble-free running.