mysql limit 1 性能_MySQL 用 limit 为什么会影响性能?

一.前言

首先说明一下MySQL的版本:

mysql> selectversion();+-----------+

| version() |

+-----------+

| 5.7.17 |

+-----------+

1 row in set (0.00 sec)

表结构:

mysql> desctest;+--------+---------------------+------+-----+---------+----------------+

| Field | Type | Null | Key | Default | Extra |

+--------+---------------------+------+-----+---------+----------------+

| id | bigint(20) unsigned | NO | PRI | NULL | auto_increment |

| val | int(10) unsigned | NO | MUL | 0 | |

| source | int(10) unsigned | NO | | 0 | |

+--------+---------------------+------+-----+---------+----------------+

3 rows in set (0.00sec)

id为自增主键,val为非唯一索引。

灌入大量数据,共500万:

mysql> select count(*) fromtest;+----------+

| count(*) |

+----------+

| 5242882 |

+----------+

1 row in set (4.25 sec)

我们知道,当limit offset rows中的offset很大时,会出现效率问题:

mysql> select * from test where val=4 limit 300000,5;+---------+-----+--------+

| id | val | source |

+---------+-----+--------+

| 3327622 | 4 | 4 |

| 3327632 | 4 | 4 |

| 3327642 | 4 | 4 |

| 3327652 | 4 | 4 |

| 3327662 | 4 | 4 |

+---------+-----+--------+

5 rows in set (15.98 sec)

为了达到相同的目的,我们一般会改写成如下语句:

mysql> select * from test a inner join (select id from test where val=4 limit 300000,5) b on a.id=b.id;

+---------+-----+--------+---------+

| id | val | source | id |

+---------+-----+--------+---------+

| 3327622 | 4 | 4 | 3327622 |

| 3327632 | 4 | 4 | 3327632 |

| 3327642 | 4 | 4 | 3327642 |

| 3327652 | 4 | 4 | 3327652 |

| 3327662 | 4 | 4 | 3327662 |

+---------+-----+--------+---------+

5 rows in set (0.38 sec)

时间相差很明显。

为什么会出现上面的结果?我们看一下select * from test where val=4 limit 300000,5;的查询过程:

查询到索引叶子节点数据。

根据叶子节点上的主键值去聚簇索引上查询需要的全部字段值。

类似于下面这张图

8b848ddb52412bbbd633943043771b67.png

像上面这样,需要查询300005次索引节点,查询300005次聚簇索引的数据,最后再将结果过滤掉前300000条,取出最后5条。MySQL耗费了大量随机I/O在查询聚簇索引的数据上,而有300000次随机I/O查询到的数据是不会出现在结果集当中的。

肯定会有人问:既然一开始是利用索引的,为什么不先沿着索引叶子节点查询到最后需要的5个节点,然后再去聚簇索引中查询实际数据。这样只需要5次随机I/O,类似于下面图片的过程:

a401850df57905990a1a2be90d7e9ec5.png

其实我也想问这个问题。

证实

下面我们实际操作一下来证实上述的推论:

为了证实

select * from test where val=4 limit 300000,5

是扫描300005个索引节点和300005个聚簇索引上的数据节点,我们需要知道MySQL有没有办法统计在一个sql中通过索引节点查询数据节点的次数。我先试了Handler_read_*系列,很遗憾没有一个变量能满足条件。

我只能通过间接的方式来证实:

InnoDB中有buffer pool。里面存有最近访问过的数据页,包括数据页和索引页。所以我们需要运行两个sql,来比较buffer pool中的数据页的数量。预测结果是运行select * from test a inner join (select id from test where val=4 limit 300000,5) b>之后,buffer pool中的数据页的数量远远少于select * from test where val=4 limit 300000,5;对应的数量,因为前一个sql只访问5次数据页,而后一个sql访问300005次数据页。

select * from test where val=4 limit 300000,5mysql> select index_name,count(*) from information_schema.INNODB_BUFFER_PAGE where INDEX_NAME in('val','primary') and TABLE_NAME like '%test%' group byindex_name;

Emptyset (0.04 sec)

可以看出,目前buffer pool中没有关于test表的数据页。

mysql> select * from test where val=4 limit 300000,5;+---------+-----+--------+

| id | val | source |

+---------+-----+--------+

| 3327622 | 4 | 4 |

| 3327632 | 4 | 4 |

| 3327642 | 4 | 4 |

| 3327652 | 4 | 4 |

| 3327662 | 4 | 4 |

+---------+-----+--------+

5 rows in set (26.19 sec)

mysql> select index_name,count(*) from information_schema.INNODB_BUFFER_PAGE where INDEX_NAME in('val','primary') and TABLE_NAME like '%test%' group byindex_name;+------------+----------+

| index_name | count(*) |

+------------+----------+

| PRIMARY | 4098 |

| val | 208 |

+------------+----------+

2 rows in set (0.04 sec)

可以看出,此时buffer pool中关于test表有4098个数据页,208个索引页。

select * from test a inner join (select id from test where val=4 limit 300000,5) b>为了防止上次试验的影响,我们需要清空buffer pool,重启mysql。

mysqladmin shutdown

/usr/local/bin/mysqld_safe &mysql> select index_name,count(*) from information_schema.INNODB_BUFFER_PAGE where INDEX_NAME in('val','primary') and TABLE_NAME like '%test%' group byindex_name;

Emptyset (0.03 sec)

运行sql:

mysql> select * from test a inner join (select id from test where val=4 limit 300000,5) b on a.id=b.id;+---------+-----+--------+---------+

| id | val | source | id |

+---------+-----+--------+---------+

| 3327622 | 4 | 4 | 3327622 |

| 3327632 | 4 | 4 | 3327632 |

| 3327642 | 4 | 4 | 3327642 |

| 3327652 | 4 | 4 | 3327652 |

| 3327662 | 4 | 4 | 3327662 |

+---------+-----+--------+---------+

5 rows in set (0.09 sec)

mysql> select index_name,count(*) from information_schema.INNODB_BUFFER_PAGE where INDEX_NAME in('val','primary') and TABLE_NAME like '%test%' group byindex_name;+------------+----------+

| index_name | count(*) |

+------------+----------+

| PRIMARY | 5 |

| val | 390 |

+------------+----------+

2 rows in set (0.03 sec)

我们可以看明显的看出两者的差别:第一个sql加载了4098个数据页到buffer pool,而第二个sql只加载了5个数据页到buffer pool。符合我们的预测。也证实了为什么第一个sql会慢:读取大量的无用数据行(300000),最后却抛弃掉。

而且这会造成一个问题:加载了很多热点不是很高的数据页到buffer pool,会造成buffer pool的污染,占用buffer pool的空间。

遇到的问题

为了在每次重启时确保清空buffer pool,我们需要关闭innodb_buffer_pool_dump_at_shutdown和innodb_buffer_pool_load_at_startup,这两个选项能够控制数据库关闭时dump出buffer pool中的数据和在数据库开启时载入在磁盘上备份buffer pool的数据。

参考资料:

1.https://explainextended.com/2009/10/23/mysql-order-by-limit-performance-late-row-lookups/

2.https://dev.mysql.com/doc/refman/5.7/en/innodb-information-schema-buffer-pool-tables.html

作者:zhangyachen

来源:https://dwz.cn/K1Q1cePW

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值