蒂森服务器显示0009,蒂森故障诊断

诊断仪显示FC01 对策:

1.X24插头线错误; 1.检查接线;

2.缓冲器限位开关被按下; 2.检查限位开关;

3.主板损坏; 3.更换主板;

4.24V电压异常 4.检查直流电源

Diagnostic tool displays "FC01" SOLVE:

1.Incorrect X24 plug wiring ; 1.correct X24 plug wiring ;

2.Effective buffer limit switch; 2.Effective buffer limit switch;

3.Defective main board; 3.Efective main board;

4.24V power misfunction 4.24V power misfunction

电梯无预开门功能对策:

1、主板上J402的1-2脚未连接; 1.连接1-2脚(旧板);

2、X91,X92,X93未短接; 2.连接端子;

3、特殊功能A6未运行; 3.运行特殊功能A6;

4、MC2主板损坏 4.更换主板

Missing pre-opening function SOLVE:

1.J4021-2 disconnected; 1. Connect jumper 1-2(old board);

2.X91,X92,X93 NOT short circuiting; 2.Short circuit X91 92 93;

3.Ineffective A6; 3.Effective A6;

4.MC2 main board damaged 4.Replace main board

到达某层后门不开,继续寻层对策:

1、门机故障 1.检查门机;

2、门接线错误(133和137错线) 2.纠正错线;

3、门锁弹簧力不够 3.增加弹簧压缩量,或更换新门锁弹簧(簧径1.0) Improper releveling SOLVE:

1.Defective door operator; 1.Check door operator;

2.Incorrect wiring(133&137); 2.Correct wiring;

3.Slack door lock spring 3.Adjust spring or replace spring(diameter 1.0)

井道无法正常自学习对策:

1、码板安装位置错误; 1.调整位置;

2、24V电源异常; 2.检查电源;

3、LN/LK选层器之间距离错误; 3.调整距离;

4、选层器损坏; 4.更换选层器;

5、主板故障(E900); 5.更换主板;

6、MF3板故障; 6.更换MF3板;

7、检查CANBUS接地; 7.按要求接地;

8、轿箱显示板短路8.更换显示板

Ineffective hoistway self-learning SOLVE:

1.Incorrect landing vane position; 1.Adjust position;

2.Misfunction 24V power; 2.check power;

3.Improper LN/LK selector distance; 3.Adjust distance;