诊断仪显示FC01 对策:
1.X24插头线错误; 1.检查接线;
2.缓冲器限位开关被按下; 2.检查限位开关;
3.主板损坏; 3.更换主板;
4.24V电压异常 4.检查直流电源
Diagnostic tool displays "FC01" SOLVE:
1.Incorrect X24 plug wiring ; 1.correct X24 plug wiring ;
2.Effective buffer limit switch; 2.Effective buffer limit switch;
3.Defective main board; 3.Efective main board;
4.24V power misfunction 4.24V power misfunction
电梯无预开门功能对策:
1、主板上J402的1-2脚未连接; 1.连接1-2脚(旧板);
2、X91,X92,X93未短接; 2.连接端子;
3、特殊功能A6未运行; 3.运行特殊功能A6;
4、MC2主板损坏 4.更换主板
Missing pre-opening function SOLVE:
1.J4021-2 disconnected; 1. Connect jumper 1-2(old board);
2.X91,X92,X93 NOT short circuiting; 2.Short circuit X91 92 93;
3.Ineffective A6; 3.Effective A6;
4.MC2 main board damaged 4.Replace main board
到达某层后门不开,继续寻层对策:
1、门机故障 1.检查门机;
2、门接线错误(133和137错线) 2.纠正错线;
3、门锁弹簧力不够 3.增加弹簧压缩量,或更换新门锁弹簧(簧径1.0) Improper releveling SOLVE:
1.Defective door operator; 1.Check door operator;
2.Incorrect wiring(133&137); 2.Correct wiring;
3.Slack door lock spring 3.Adjust spring or replace spring(diameter 1.0)
井道无法正常自学习对策:
1、码板安装位置错误; 1.调整位置;
2、24V电源异常; 2.检查电源;
3、LN/LK选层器之间距离错误; 3.调整距离;
4、选层器损坏; 4.更换选层器;
5、主板故障(E900); 5.更换主板;
6、MF3板故障; 6.更换MF3板;
7、检查CANBUS接地; 7.按要求接地;
8、轿箱显示板短路8.更换显示板
Ineffective hoistway self-learning SOLVE:
1.Incorrect landing vane position; 1.Adjust position;
2.Misfunction 24V power; 2.check power;
3.Improper LN/LK selector distance; 3.Adjust distance;