dell服务器操作系统带命令行,DELL服务器命令行配置RAID

查看所有磁盘

racadm -r 10.253.193.75 -u root -p xx storage get pdisks

Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1

Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1

Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1

Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1

Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1

Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1

查看所有磁盘详细信息racadm -r 10.253.193.75 -u root -p xx storage get pdisks -o

Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1

Status                           = Ok

DeviceDescription                = Disk 5 in Backplane 1 of Integrated RAID Controller 1

RollupStatus                     = Ok

Name                             = Physical Disk 0:1:5

State                            = Online

OperationState                   = Not Applicable

PowerStatus                      = Spun-Up

Size                             = 1117.25 GB

查看raid名称

racadm -r 10.253.193.75 -u root -p xx storage get vdisks

Disk.Virtual.0:RAID.Integrated.1-1

Disk.Virtual.1:RAID.Integrated.1-1

查看raid详细信息、大小

racadm -r 10.253.193.75 -u root -p xx storage get vdisks -o

Disk.Virtual.0:RAID.Integrated.1-1

Status                           = Ok

DeviceDescription                = Virtual Disk 0 on Integrated RAID Controller 1

Name                             = Virtual Disk 0

RollupStatus                     = Ok

State                            = Online

OperationalState                 = Not applicable

Layout                           = Raid-1

Size                             = 1117.25 GB

SpanDepth                        = 1

AvailableProtocols               = SAS

MediaType                        = HDD

ReadPolicy                       = Read Ahead

WritePolicy                      = Write Back

StripeSize                       = 64K

DiskCachePolicy                  = Default

BadBlocksFound                   = NO

Secured                          = NO

RemainingRedundancy              = 1

EnhancedCache                    = Not Applicable

T10PIStatus                      = Disabled

BlockSizeInBytes                 = 512

查看raid卡型号

注释: 例如H330或者H770

racadm -r 10.253.193.75 -u root -p xx storage get controllers -o

RAID.Integrated.1-1

Status                           = Ok

DeviceDescription                = Integrated RAID Controller 1

RollupStatus                     = Ok

Name                             = PERC H730P Mini (Embedded)

删除raid

注释:raid的名称从"查看raid名称" 中得到

racadm -r 10.253.193.75 -u root -p xx storage deletevd:Disk.Virtual.1:RAID.Integrated.1-1

把磁盘转换成非raid(直通)模式

注释: non+raid       如果拆完raid。不把磁盘格式转化为直通模式,磁盘是不显示的

racadm -r 10.253.193.75 -u root -p xx  storage converttononraid:Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttononraid:Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttononraid:Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttononraid:Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1

把磁盘转换成raid模式

注释: 再配置raid之前,需要先把磁盘转化为raid模式,才能配置raid

racadm -r 10.253.193.75 -u root -p xx storage converttoraid:Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttoraid:Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttoraid:Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1

racadm -r 10.253.193.75 -u root -p xx storage converttoraid:Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1

配置raid(2,3,4,5磁盘,raid10)

注释: r5 代表raid模式

RAID.Integrated.1-1 名称即从 "查看job名称"得出

racadm -r 10.253.193.75 -u root -p xx storage createvd:RAID.Integrated.1-1 -rl r5 -pdkey:Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1,Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.

查看job名称

注释: 什么叫job,就是你操作的这个模块具体名称

racadm -r 10.253.193.75 -u root -p xx storage get controllers

RAID.Integrated.1-1

AHCI.Embedded.1-1

AHCI.Embedded.2-1

查看job号

注释: RAID.Integrated.1-1 名称即从 "查看job名称" 中得出来的

racadm -r 10.253.193.75 -u root -p xx jobqueue create RAID.Integrated.1-1 -s TIME_NOW --realtime

提交job

注释: 提交完job的,你所做的方可生效

racadm -r 10.253.193.75 -u root -p xx jobqueue view -i xxxx