内核模块
加载 ipmi_devintf 和 ipmi_si 后,会生成 /dev/ipmi0。
ps: 获取传感器信息请安装 lm-sensors,然后运行 sensors-detect。
常见ipmitool
$ ipmitool bmc reset cold #Reset BMC/DRAC to default
$ ipmitool –I open bmc info #check BMC info
$ ipmitool sel #check SEL log
$ ipmitool sel list #list SEL log
$ ipmitool raw 0x34 0x11 #Check which node you are in [For Dell Cloud edge]
$ ipmitool lan set 1 ipsrc static #Set BMC/DRAC static IP
$ ipmitool lan set 1 ipaddr #Set BMC/DRAC IP Address
$ ipmitool lan set 1 netmask #Set BMC/DRAC Subnet Mask
$ ipmitool lan set 1 defgw ipaddr #Set BMC/DRAC Default Gateway
$ ipmitool lan set 1 defgw macaddr 00:0e:0c:aa:8e:13 #Set BMC/DRAC Default Gateway mac address
$ ipmitool lan set 1 arp respond on #Enable arp
$ ipmitool lan set 1 auth ADMIN MD5 #Enable auth
$ ipmitool lan set 1 access on #allow acc