BACKGROUND: Efavirenz (EFV) is one of the preferred components of first-line antiretroviral treatment. EFV is characterized by a long plasma half-life (40-55 hours) with large interpatient variability, which raises the potential for individualization of therapy. Analyses of EFV levels in plasma require specialized facilities (cold storage/transport) which, in resource-limited settings, can be problematic; dried blood spots (DBS)-EFV measurements thus provide a cheap easy alternative for therapeutic drug monitoring. Our aim was to develop and validate a liquid chromatography-mass spectrometry method to quantify EFV in DBS collected as part of clinical trials in resource-limited settings. METHODS: DBS for standards, quality control samples, and patient samples were excised and then extracted with ethyl acetate/n-hexane (50/50 vol/vol) after addition of internal standard hexobarbital, and 1 mol/L K2CO3. The extract was evaporated to dryness, the residue reconstituted in mobile phase and analyzed directly by liquid chromatography-mass spectrometry. Gradient elution was on a reverse-phase C18 column using 1 mmol/L ammonium acetate in water and acetonitrile. Quantification was by selected reaction monitoring in negative ionization mode. DBS samples were obtained at several time points over 24 hours from HIV+ patients on either 400 or 600 mg EFV in combination with emtricitabine/tenofovir. RESULTS: The internal standard and EFV eluted at 2.68 and 3.54 minutes, respectively in a 5-minute run time. Matrix effects were minimal (-5.4%). Calibration curves were validated over a concentration range of 25-5000 ng/mL. Intra-assay and interassay variations ranged between 6.7% and 8.7% for imprecision and 100.3% and 104.2% for accuracy. Mean recovery was >64%. The DBS data showed a strong positive correlation with a validated plasma EFV assay (R = 0.9764, P < 0.001). EFV concentrations from DBS were approximately 42% lower than the paired plasma values, and the ratio of blood/plasma did not change over the dosing interval. CONCLUSIONS: The validated assay is now routinely applied to clinical samples measuring DBS EFV for pharmacokinetic analysis. The methodology is robust, accurate, and sensitive.

展开

评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值