一、现象描述
一台IBM小型机,带RAID卡,内置3块硬盘,做RAID5,无热备
第2块硬盘亮黄色故障灯
二、做好rootvg备份(mksysb)和数据备份(强烈建议)
备份完数据后,为了安全,停止应用对硬盘的访问
三、故障确认
执行lsdev–Cc pdisk/hdisk、errpt命令查看系统是否有硬盘报错
用diag->Task selection -> RAID Array Manager ->
IBM SASDisk Array Manager ->List IBM SASDisk Array configuration检查raid信息和pdisk的状态
hdisk00B-08-ff-0,0DegradedRAID 5 Array484.2GB
pdisk00B-08-00-5,0FailedArray Member242.8GB
pdisk10B-08-01-5,0ActiveArray Member242.8GB
pdisk20B-08-00-3,0ActiveArray Member242.8GB
用以下操作再次确认硬盘槽位信息:
Diag->Task Selection->RAID Array Manager->IBM SASDisk Array Manager-> Diagnostics and Recovery Options->SCSI and SCSI RAID Hot Plug Manager-> Identify a Device Attached to a SCSI Hot Swap Enclosure Device
选择对应的硬盘,按F7确认硬盘所在的槽位(磁盘的黄灯在闪烁)
四、进行磁盘更换