官方参考文档
WMI C++ Application Examples
// WmiLean.cpp : Defines the entry point for the console application.
//
#include "stdafx.h"
#include <conio.h>
#include <comutil.h>
#include <objbase.h>
#include <wbemidl.h>
#pragma comment(lib, "wbemuuid.lib")
#pragma comment(lib, "comsuppw.lib")
BOOL WMIGetCurrentTemperature(float *pfTemperature)
{
BOOL bRet = FALSE;
HRESULT hres = S_OK;
IWbemServices *pSvc = NULL;
IWbemLocator *pLoc = NULL;
IEnumWbemClassObject* pEnumerator = NULL;
IWbemClassObject *pclsObj = NULL;
// Step 1: --------------------------------------------------
// Initialize COM. ------------------------------------------
CoInitializeEx(NULL, COINIT_APARTMENTTHREADED);
do
{
// Step 2: --------------------------------------------------
// Set general COM security levels --------------------------
// Note: If you are using Windows 2000, you need to specify -
// the default authentication credentials for a user by using
// a SOLE_AUTHENTICATION_LIST structure in the pAuthList ----
// parameter of CoInitializeSecurity ------------------------
hres = CoInitializeSecurity(
NULL,
-1, // COM authentication
NULL, // Authentication services
NULL, // Reserved
RPC_C_AUTHN_LEVEL_DEFAULT, // Default authentication
RPC_C_IMP_LEVEL_IMPERSONATE, // Default Impersonation
NULL, // Authentication info
EOAC_NONE, // Additional capabilities
NULL // Reserved
);
if (FAILED(hres))
{
_tprintf(_T("Failed to initialize security. Error code = 0x%08X\n"), hres);
break; // Program has failed.
}
// Step 3: ---------------------------------------------------
// Obtain the initial locator to WMI -------------------------
hres = CoCreateInstance(
CLSID_WbemLocator,
0,
CLSCTX_INPROC_SERVER,
IID_IWbemLocator, (LPVOID *) &pLoc);
if (FAILED(hres))
{
_tprintf( _T("Failed to create IWbemLocator object. Err code = 0x%08X\n"), hres);
break; // Program has failed.
}
// Step 4: -----------------------------------------------------
// Connect to WMI through the IWbemLocator::ConnectServer method
// Connect to the root\cimv2 namespace with
// the current user and obtain pointer pSvc
// to make IWbemServices calls.
hres = pLoc->ConnectServer(
_bstr_t(L"ROOT\\WMI"), // Object path of WMI namespace
NULL, // User name. NULL = current user
NULL, // User password. NULL = current
0, // Locale. NULL indicates current
NULL, // Security flags.
0, // Authority (e.g. Kerberos)
0, // Context object
&pSvc // pointer to IWbemServices proxy
);
if (FAILED(hres))
{
_tprintf( _T("Could not connect. Error code = 0x%08X\n"), hres);
break; // Program has failed.
}
//_tprintf( _T("Connected to ROOT\\WMI WMI namespace\n") );
// Step 5: --------------------------------------------------
// Set security levels on the proxy -------------------------
hres = CoSetProxyBlanket(
pSvc, // Indicates the proxy to set
RPC_C_AUTHN_WINNT, // RPC_C_AUTHN_xxx
RPC_C_AUTHZ_NONE, // RPC_C_AUTHZ_xxx
NULL, // Server principal name
RPC_C_AUTHN_LEVEL_CALL, // RPC_C_AUTHN_LEVEL_xxx
RPC_C_IMP_LEVEL_IMPERSONATE, // RPC_C_IMP_LEVEL_xxx
NULL, // client identity
EOAC_NONE // proxy capabilities
);
if (FAILED(hres))
{
_tprintf( _T("Could not set proxy blanket. Error code = 0x%08X"), hres);
break;; // Program has failed.
}
// Step 6: --------------------------------------------------
// Use the IWbemServices pointer to make requests of WMI ----
// For example, get the name of the operating system
hres = pSvc->ExecQuery(
bstr_t("WQL"),
bstr_t("SELECT * FROM MSAcpi_ThermalZoneTemperature"),
WBEM_FLAG_FORWARD_ONLY | WBEM_FLAG_RETURN_IMMEDIATELY,
NULL,
&pEnumerator);
if (FAILED(hres))
{
_tprintf( _T("Query for MSAcpi_ThermalZoneTemperature failed. Error code = 0x%08X"), hres);
break; // Program has failed.
}
// Step 7: -------------------------------------------------
// Get the data from the query in step 6 -------------------
ULONG uReturn = 0;
while (pEnumerator)
{
HRESULT hr = pEnumerator->Next(WBEM_INFINITE, 1,
&pclsObj, &uReturn);
if(0 == uReturn)
{
break;
}
VARIANT vtProp;
VariantInit(&vtProp);
// Get the value of the Name property
hr = pclsObj->Get(L"CurrentTemperature", 0, &vtProp, 0, 0);
if(hr == WBEM_S_NO_ERROR && vtProp.vt != VT_NULL)
{
//_tprintf( _T("CurrentTemperature: %u\n"), vtProp.ulVal );
if(pfTemperature)
{
*pfTemperature = (vtProp.ulVal - 3272f)/ 10.0f;
}
bRet = 1;
}
VariantClear(&vtProp);
}
}while(0);
//Step 8 Cleanup
// =======
if(pSvc)
pSvc->Release();
if(pLoc)
pLoc->Release();
if(pEnumerator)
pEnumerator->Release();
if(pclsObj)
pclsObj->Release();
CoUninitialize();
return bRet;
}
int _tmain(int argc, _TCHAR* argv[])
{
do
{
float fTemp = 0;
if(WMIGetCurrentTemperature(&fTemp))
{
printf("temp = %f\n", fTemp);
}
}while(! _kbhit() );
return 0;
}