Dell EMC PowerEdge RAID Controller 10 PERC H345, H740P, H745, H745P MX, and H840

FeaturePERC H345PERC H740PPERC H745PERC H745P MXPERC H840
RAID levels0, 1, 100, 1, 5, 6, 10, 50, 600, 1, 5, 6, 10, 50, 600, 1, 5, 6, 10, 50, 600, 1, 5, 6, 10, 50, 60
Non-RAIDYesYesYesYesN/A
Enclosures per portNot applicableNot applicableNot applicableNot applicable4
ProcessorDell adapter SAS RAID-on-chip, 16-port with LSI 3416 chipsetDell adapter SAS RAID-on-chip, 8-port with LSI 3508 chipsetDell adapter SAS RAID-on-chip, 16-port with LSI 3516 chipsetDell adapter SAS RAID-on-chip, 16-port with LSI 3516 chipsetDell adapter SAS RAID-on-chip, 8-port with LSI 3508 chipset
Battery backup unitNoYesYesYesYes
eHBANoYesYesYesNo
LKM securityNoYesYesYesYes
Controller queue depth (RAID mode)15364096409630724096 with PD64 profile, 3072 with PD240 profile
Controller Queue Depth (eHBA)N/A512051205120N/A
Enterprise key manager modeNoYesYesNoNo
Nonvolatile cacheNoYesYesYesYes
Cache memoryN/A8 GB DDR4 2133 Mhz cache4 GB DDR4 2133 Mhz cache8 GB DDR4 2133 Mhz cache8 GB DDR4 2133 Mhz cache
Cache functionWrite through and no read ahead.Write back, write through, no read ahead, and read ahead.Write back, write through, no read ahead, and read ahead.Write back, write through, no read ahead, and read ahead.Write back, write through, no read ahead, and read ahead.
Max no of VDs in RAID mode326464240240
Max no of disks in eHBA modeNot applicable240 (combination of virtual disks and Non-Raid disks).240 (combination of virtual disks and Non-Raid disks)240 ( combination of virtual disks and Non-Raid disks).Not applicable
Max no of VDs per disk group1616161616
Max no of disk groups326464240240
Hot swap devices supportedYesYesYesYesYes
Hardware XOR engineNot applicableYesYesYesYes
Online capacity expansionYes in operating system onlyYesYesYesYes
Dedicated and global hot spareYesYesYesYesYes
AutoconfigureN/ARAID 0RAID 0RAID 0RAID 0
Drives types3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS3 Gbps SATA, 6 Gbps SATA/SAS, and 12 Gbps SAS6 Gbps SAS, and 12 Gbps SAS
VD strip size64 kB64 kB, 128 kB, 256 kB, 512 kB, 1 MB64 kB, 128 kB, 256 kB, 512 kB, 1 MB64 kB, 128 kB, 256 kB, 51 2 kB, 1 MB64 kB, 128 kB, 256 kB, 512 kB, 1 MB
PCIe supportGen 3Gen 3Gen 3Gen 3Gen 3
Maximum drive support
  • Without SAS Expander: 16 per controller
  • With SAS Expander: Limited by platform offering
  • Without SAS Expander: 8 drives per controller
  • With SAS Expander: Limited by platform offering
  • Without SAS Expander: 16 drives per controller
  • With SAS Expander: Limited by platform offering
  • Without SAS Expander: 16 drives per controller
  • With SAS Expander: Limited by platform offering
240
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包

打赏作者

frank0060071

你的鼓励将是我创作的最大动力

¥1 ¥2 ¥4 ¥6 ¥10 ¥20
扫码支付:¥1
获取中
扫码支付

您的余额不足,请更换扫码支付或充值

打赏作者

实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值