hpux- hp小型机日常硬件故障处理case(二)

在一台HP Superdome Server SD32A上遇到Cell 2面板指示灯不亮的问题,通过分析日志确定为Cell Board的FSB故障。经过更换CPB和FSB固件后,Cell 2恢复正常,内存和CPU成功识别。
摘要由CSDN通过智能技术生成

主机型号:ia64 hp superdome server SD32A

存储型号:XP24000

软件版本:hpux 11.31 + oracle 11g 

LED显示:attention 红灯

故障现象:cell 2 面板指示灯不亮,cell 2 出现故障

日志:

Log Entry 39897: 06/02/2013 08:35:49
Alert level 5: Critical
Keyword: PD_ERROR_REACHABLE_SET
The cell is not able to reach all requested cells through the fabric.
Reporting Entity: System Firmware located in cabinet 0, slot 1, cpu 0
Actual Data: 0x0000000000000053
0xa380020310e01800 0x0000000000000053
0xab00020310e01801 0x0100000051ab03e5

MP:VWR (,,+,-,?,F,L,J,D,K,R,T,A,C,U,^B) >
Log Entry 39897: 06/02/2013 08:35:49
Alert level 5: Critical
Keyword: PD_ERROR_REACHABLE_SET
The cell is not able to reach all requested cells through the fabric.
Reporting Entity: System Firmware located in cabinet 0, slot 1, cpu 0
Actual Data: 0x0000000000000053
0xa380020310e01800 0x0000000000000053
0xab00020310e01801 0x0100000051ab03e5

Log Entry 39896: 06/02/2013 08:35:49
Alert level 3: Warning
Keyword: ERM
The Error Response Mode has been determined
Reporting Entity: System Firmware located in cabinet 0, slot 0, cpu 0
Text Message: "CONTINUE"
0x698001ee00e017fe 0x45554e49544e4f43
0x6b0001ee00e017ff 0x0100000051ab03e5

 

W status for Cell 2 in cabinet 0: FAILURE DETECTED
Cell power Status: enabled, OF