为了更好地与draft进行对应,看HM中的反量化部分代码:
Void TComTrQuant::xDeQuant(Int bitDepth, const TCoeff* pSrc, Int* pDes, Int iWidth, Int iHeight, Int scalingListType )
{
const TCoeff* piQCoef = pSrc;
Int* piCoef = pDes;
if ( iWidth > (Int)m_uiMaxTrSize )
{
iWidth = m_uiMaxTrSize;
iHeight = m_uiMaxTrSize;
}
Int iShift,iAdd,iCoeffQ;
UInt uiLog2TrSize = g_aucConvertToBit[ iWidth ] + 2;
Int iTransformShift = MAX_TR_DYNAMIC_RANGE - bitDepth - uiLog2TrSize;
iShift = QUANT_IQUANT_SHIFT - QUANT_SHIFT - iTransformShift; //!< draft (8-240)、(8-241)
//! iShift = bitDepth + uiLog2 - 5 - 4
//! 注意,这个结果比draft中多减了个4,这是因为此时scaling_list_enable_flag默认情况下为0,则m[x][y]为16,比较
//! 式(8-250)可知代码中并未乘以m[x][y],而iShift比式子小了4(相当于总结果少除以16),故代码与draft两者是一致的
TCoeff clipQCoef;