DELL R710在RAID10环境下故障硬盘热插拔替换

 服务器信息: DELL R710146G*6块硬盘,RAID10,其中1块硬盘故障。

1)查看硬盘信息

# /usr/sbin/MegaCli –PDList –aAll –NoLog

Enclosure Device ID: 32

Slot Number: 4

Drive's position: DiskGroup: 0, Span: 2, Arm: 0

Enclosure position: N/A

Device Id: 4

……..

Raw Size: 136.732 GB [0x11177328 Sectors]

Non Coerced Size: 136.232 GB [0x11077328 Sectors]

Coerced Size: 136.125 GB [0x11040000 Sectors]

Sector Size:  0

Firmware state: Failed

Device Firmware Level: HS0F

2)卸载故障硬盘

# MegaCli -PDOffline -PhysDrv[32:4] -a0

324的对应关系:

Enclosure Device ID: 32

   Slot Number: 4

3)替换故障硬盘

此时故障硬盘已经OFFLINE,在服务器现场查看时,故障硬盘闪烁的是黄灯,非正常硬盘的绿灯;

拔下故障硬盘,插上好硬盘,硬盘灯闪烁为绿色,并硬盘快速旋转。

4)重建故障硬盘

RAID10会自动重建替换的硬盘

5)查看故障硬盘重建进度

查看重建进度的命令:

# MegaCli -PDRbld -ShowProg -PhysDrv[32:4] –aAll

Rebuild Progress on Device at Enclosure 32, Slot 4 Completed 40% in 8 Minutes.

6)DELL R710服务器RAID10模式下,故障硬盘替换完毕。

来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/26390465/viewspace-1771469/,如需转载,请注明出处,否则将追究法律责任。

转载于:http://blog.itpub.net/26390465/viewspace-1771469/

  • 0
    点赞
  • 2
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值