服务器信息: DELL R710,146G*6块硬盘,RAID10,其中1块硬盘故障。
1)查看硬盘信息
# /usr/sbin/MegaCli –PDList –aAll –NoLog
Enclosure Device ID: 32
Slot Number: 4
Drive's position: DiskGroup: 0, Span: 2, Arm: 0
Enclosure position: N/A
Device Id: 4
……..
Raw Size: 136.732 GB [0x11177328 Sectors]
Non Coerced Size: 136.232 GB [0x11077328 Sectors]
Coerced Size: 136.125 GB [0x11040000 Sectors]
Sector Size: 0
Firmware state: Failed
Device Firmware Level: HS0F
2)卸载故障硬盘
# MegaCli -PDOffline -PhysDrv[32:4] -a0
32和4的对应关系:
Enclosure Device ID: 32
Slot Number: 4
3)替换故障硬盘
此时故障硬盘已经OFFLINE,在服务器现场查看时,故障硬盘闪烁的是黄灯,非正常硬盘的绿灯;
拔下故障硬盘,插上好硬盘,硬盘灯闪烁为绿色,并硬盘快速旋转。
4)重建故障硬盘
RAID10会自动重建替换的硬盘
5)查看故障硬盘重建进度
查看重建进度的命令:
# MegaCli -PDRbld -ShowProg -PhysDrv[32:4] –aAll
Rebuild Progress on Device at Enclosure 32, Slot 4 Completed 40% in 8 Minutes.
6)DELL R710服务器RAID10模式下,故障硬盘替换完毕。
来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/26390465/viewspace-1771469/,如需转载,请注明出处,否则将追究法律责任。