HP-UX 修改disk instance号

1.可以在2台主机上通过scsimgr -p get_attr all_lun -a hw_path -a device_file -a wwid来查看wwn,wwn一致的为同一个盘,也可以通过它与存储划得每个lun对应起来
2.通过ioinit来修改,具体过程如下:

备份先:备份ioconfig及ioscan的输出

更改过程
# ioscan –funNCdisk

Class I H/W Path Driver S/W State H/W Type Description
===================================================================
...
disk 17 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk17 /dev/rdisk/disk17
现在要将disk17改为disk28,因为我仅仅是要修改一个disk,所以就直接vi一个infile文件,如果disk比较多,ioscan加awk来做
#cat infile
64000/0xfa00/0xb disk 28
这里的64000/0xfa00/0xb是ioscan里面的disk17的H/W Path
# ioinit -f infile
# ioscan -funNCdisk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
.....
disk 28 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk17 /dev/disk/disk28 /dev/rdisk/disk17 /dev/rdisk/disk28
# rmsf /dev/disk/disk17
# rmsf /dev/rdisk/disk17

# ioscan -funNCdisk
Class I H/W Path Driver S/W State H/W Type Description
===================================================================
...
disk 28 64000/0xfa00/0xb esdisk CLAIMED DEVICE HP EF0300FATFD
/dev/disk/disk28 /dev/rdisk/disk28

主机重启后disk instance number不会发生变化

来自 “ ITPUB博客 ” ,链接:http://blog.itpub.net/14012827/viewspace-1817479/,如需转载,请注明出处,否则将追究法律责任。

转载于:http://blog.itpub.net/14012827/viewspace-1817479/