HPE 3par SS7200 扩容步骤

本文详细介绍了HPE 3par SS7200存储系统的硬盘扩容步骤,包括添加驱动器许可证、运行健康检查、进入维护模式、安装新硬盘、连接线缆、承认硬件、退出维护模式,并在每个步骤后进行健康检查,确保系统稳定。
摘要由CSDN通过智能技术生成


 

- First create andadd the new Drive license (if under 48)

- use checkhealth tosee if 3PAR is OK

- Install the Cagewith the new Disks and Power On

- prepare the SASCable

- Cable the new Shelf as found in the "7000 Series StorageCabling Configuration Guide" (if online, one Node after the other and waitbetween) http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=c04441589

- use showcage tocheck

- admithw (wait iffirmware is applied)

- showpd -c (waituntil all chunklets are initiaisized)

- use checkhealth tosee if 3PAR is OK

- use tunesys tostart leveling

开机步骤

Powering On the Storage System 2. 3. 4. 5. 6. Set the circuit breakers on the PDUs to the ON position. Set the switches on the power strips to the ON position. NOTE: Some power strips may not have power switches. Power on the service processor. Power on the drive enclosure PCMs. Power on the node enclosure PCMs. After approximately 10 minutes, allowing time for the system to boot and the cache batteries to charge, verify the status of the LEDs as described in "Verifying LED Status" (page 55).

指示灯

NOTE: If any module fault or disk drive LEDs are not green, do not proceed until the problem is resolved. figure 35 Bezel LEDs Table 7 Identifying Bezel LEDs 2 3 Pcnver indicator Module fault Disk drive status

 

Table 8 Identifying Disk Drive LEDs 2 Amber LED indicates a fault. Green LED indicates the system is ready.

 

su ux · 00 VDd6 · R01

 

9 PCM LED Descriptions (continued) Faa 38 LEOS %hing %hing Set NOTE: The figure an SPAR 7200 os an exa

 

•poN-r 6E suod peuum.alul epoN

 

Drive Enclosure LEDs figure 40 Drive Enclosure PCM LEDs o o CAUTION: DO not proceed Without first correcting all fault indications (except for PCM batteries). NOTE: The batteries are fully charged during shipment. The batteries rnay loose charge and show a degraded status immediately When power is applied. This is a temporary condition. Proceed With the system initialization and software installation. Check the LEDs again When the installation is complete. The duster is not formed until the storage system software installation has been performed.

 

Identifying Service Processor LEDs The HP 3PAR SP (Proliant DL320e) LEDs are located at the front and rear Of the SP. Figure 41 Front LEDs o

 

4 LIID LED/ button button and powg Health NIC Flashing Blue Green Green Flashing Red Green System is being managed rernotely System is on Waiting for System is on power Still cord is not attached supplied has System is on and System f-•lth is System is degraded System is critical System is OH to activity NO network link

 

 

or Flashing Green Blue 4 NIC link NIC ShtuS UI D LED/button NOTE: May rbt be a to Off (for hot-plug HP CS supplies ONLY) NO link NO activity is managed Off z or more Of the 'OllOwing • Power i Power Supply has failed Power Supply is in mode Power Supply error

 

更换HPE 3par ss8400存储系统的故障CNA(Converged Network Adapter)需要进行以下步骤: 1. 首先,确认新的CNA已经获取到,可以与3par存储系统兼容。 2. 然后,使用管理员账户登录3par管理界面,点击“系统”选项卡,选择“状态”菜单,查看当前存储系统的状态和信息。 3. 找到故障的CNA,查看CNA状态和故障信息。如果CNA无法修复,需要更换CNA。 4. 找到存储系统中需要更换CNA的节点,确定CNA的位置和型号。 5. 确认需要更换的CNA位置后,使用管理员账户登录存储系统的CLI界面。 6. 进入CLI界面后,使用以下命令检查CNA状态: ``` showport -cna -i ``` 7. 确认需要更换的CNA位置后,使用以下命令将存储系统进入维护模式: ``` setmaint -on ``` 8. 然后,使用以下命令关闭存储系统的节点: ``` haltnode -force <node ID> ``` 其中,`<node ID>`为需要关闭的节点的ID。 9. 等待存储系统节点关闭后,打开存储系统的机箱,并找到需要更换的CNA。 10. 将故障CNA从插槽中取出,然后插入新的CNA。确保CNA插入正确的插槽中,并按照正确的方向插入。 11. 关闭存储系统的机箱,并使用以下命令重新启动存储系统的节点: ``` bootnode <node ID> ``` 12. 等待存储系统节点启动完成后,使用以下命令将存储系统退出维护模式: ``` setmaint -off ``` 13. 最后,使用CLI界面中的命令检查新CNA的状态,确认CNA更换成功: ``` showport -cna -i ``` 以上就是更换HPE 3par ss8400存储系统故障CNA的步骤。在进行此操作前,请务必备份所有重要数据,以避免数据丢失。