一次进行CFX计算的时候出现以下报错信息
Job started: Sat Apr 22 10:04:56 2023
Details of error:-
----------------
Error detected by routine PEEKCS
CDANAM = /FLOW/BOUNDCON/ZN1 /BCP1 /ALIAS
CRESLT = NONE
Current Directory : /FLOW/CONTROL/OUTPUT/MONITOR/MONP110/EXPVAL
+--------------------------------------------------------------------+
| ERROR #001100279 has occurred in subroutine ErrAction. |
| Message: |
| Stopped in routine MEMERR |
| |
| |
| |
| |
| |
+--------------------------------------------------------------------+
+--------------------------------------------------------------------+
| An error has occurred in cfx5solve: |
| |
| The ANSYS CFX partitioner exited with return code 1. |
+--------------------------------------------------------------------+
+--------------------------------------------------------------------+
| The following user files have been saved in the directory |
| /data/share/Valve/CFX/NGVO_NEW_BAND/37_NGVO_NB_Min2.22Pout0.024_R- |
| EV7200_dt3e-5_003: |
| |
| trace |
+--------------------------------------------------------------------+
因为显示的是Stopped in routine MEMERR,所以一直在修改Memory Allocate Factor,但是没什么用
最后发现是在一次计算之后修改了一个出口的名字,把Outlet修改为outlet,但是计算时又加载了之前计算的结果作为初始条件,所以报错
把出口名字改为原名之后,可以正常加载初始条件并进行计算。