指令停机包括以下停机,这些停机分别为
在维修工具中确定:
停机——低功率备用时离散
关机——RS-232关机
内部故障包括以下停机,这些停机可单独识别
在维修工具中:
关闭--所有需求都失败
关闭--A/D转换器错误
关闭——位置传感器故障
关闭--当前Fdbk失败
关闭--配置错误
关闭——校准错误
关闭--看门狗超时
主要或备份需求故障包括(在服务中单独标识
工具):
报警——模拟输入故障
报警——PWM频率错误
报警——PWM占空比错误
报警--PWM无信号
报警--Can总线关闭错误
报警--Can-Dmd无信号
报警--Can Dmd太慢
报警--跟踪错误
内部故障报警包括(在维修工具中单独标识):
报警——温度传感器故障
报警--12V故障
报警——负9V故障
报警--5V故障
报警——参考电压错误
报警——软件错误
报警——EEPROM错误
The diagnostics messages are transmitted at a rate of once per second. This message is sent only when there is at least one active fault or in response to a request from the speed control. All the diagnostic and event bits are set appropriately to indicate their current status. The speed control will decode the bits and display the corresponding diagnostic and event codes. The speed control also logs the diagnostic and event codes as required by the application. The speed control makes the decision to shut down or run depending on the application configuration, unless the ProAct actuator has already shut down. The decision will be based on the diagnostic and event classification made in the diagnostics document.