EDAC DIMM CE Error错误导致服务器重启

 现象:

 

最近几天一个华为RH2285服务器一直不定时自动重启,基本每天一两次,查看系统日志报下面的错误,每秒记录一条错误日志

 

OS:OEL 6.5

 

$ more /var/log/message

Jul 21 08:54:32 customerkernel: EDAC MC1: 5486 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:33 customerkernel: EDAC MC1: 11480 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:34 customerkernel: EDAC MC1: 11330 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:35 customerkernel: EDAC MC1: 6584 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:36 customerkernel: EDAC MC1: 27428 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:37 customerkernel: EDAC MC1: 30113 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:38 customerkernel: EDAC MC1: 4453 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:39 customerkernel: EDAC MC1: 6269 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:40 customer kernel:EDAC MC1: 15720 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1 page:0x0offset:0x0 grain:8 syndrome:0x0)

Jul 21 08:54:41 customerkernel: EDAC MC1: 16107 CE error on CPU#1Channel#2_DIMM#1 (channel:2 slot:1page:0x0 offset:0x0 grain:8 syndrome:0x0)

 

 

分析解决:

 

这个是[EDAC (Error Detection AndCorrection)](https://www.kernel.org/doc/Documentation/edac.txt) 的日志.

 

CE Error 是 Correctable Error 的简称,另外还有 UE(Uncorrectable Error)

 

按照上面的文档, 找出错误的DIMM:

[root@customer log]# grep "[0-9]" /sys/devices/system/edac/mc/mc*/csrow*/ch*_ce_count

/sys/devices/system/edac/mc/mc0/csrow0/ch0_ce_count:0

/sys/devices/system/edac/mc/mc0/csrow0/ch1_ce_count:0

/sys/devices/system/edac/mc/mc0/csrow0/ch2_ce_count:0

/sys/devices/system/edac/mc/mc0/csrow1/ch0_ce_count:0

/sys/devices/system/edac/mc/mc0/csrow1/ch1_ce_count:0

/sys/devices/system/edac/mc/mc0/csrow1/ch2_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow0/ch0_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow0/ch1_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow0/ch2_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow1/ch0_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow1/ch1_ce_count:0

/sys/devices/system/edac/mc/mc1/csrow1/ch2_ce_count:554836518

 

查到是 /mc1/csrow1/ch2, 根据结构图:

 

       Channel 0   Channel 1

===================================

csrow0 | DIMM_A0   | DIMM_B0 |

csrow1 | DIMM_A0   | DIMM_B0 |

===================================

===================================

csrow2 | DIMM_A1   | DIMM_B1 |

csrow3 | DIMM_A1   | DIMM_B1 |

===================================

 

然后通过dmidecode查看:

[root@customer log]# dmidecode -t memory |grep 'Locator: DIMM'

       Locator: DIMM_D0

       Locator: DIMM_D1

       Locator: DIMM_E0

       Locator: DIMM_E1

       Locator: DIMM_F0

       Locator: DIMM_F1

       Locator: DIMM_A0

       Locator: DIMM_A1

       Locator: DIMM_B0

       Locator: DIMM_B1

       Locator: DIMM_C0

       Locator: DIMM_C1

       

通过服务器控制台查看内存:

 

主板上内存插槽的分布:


 

结合报错日志:kernel: EDAC MC1: 16107 CE error on CPU#1Channel#2_DIMM#1 (channel:2slot:1

应该是内存插槽DIMM_F1的问题。

 

解决:

最后我们要做的就是,把有问题的F1插槽上的内存拔出来或是更换到其它的内存插槽上面,之后系统启动后不再报错。

 

参考:

http://blog.tankywoo.com/2014/12/02/edac-dimm-ce-error.html

http://serverfault.com/questions/648240/how-can-i-find-which-memory-have-ce-error

 

 

 

 

 


 

 

 

  • 0
    点赞
  • 10
    收藏
    觉得还不错? 一键收藏
  • 2
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论 2
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值