LYG-YD局点PTN7900(V1R7C01SPH111)替换PTN3900后,与UGW设备对接的一个BFD会话不UP,回退到PTN3900后BFD会话恢复正常。
步骤 1 查看当前PTN7900设备描述符为16392的BFD会话没UP:
[A]dis bfd session all (w): State in WTR (*): State is invalid -------------------------------------------------------------------------------- Local Remote PeerIpAddr State Type InterfaceName -------------------------------------------------------------------------------- 16385 16385 1A.B.C.6 Up S_AUTO_IF 10GE10/0/9.2000 16386 4097 1A.1B.5C.38 Up S_AUTO_IF GigabitEthernet3/0/1 16387 8205 1A.1B.5C.54 Up S_AUTO_IF GigabitEthernet3/0/2 16388 8193 1A.1B.5C.6 Up S_AUTO_IF 10GE10/0/1 16390 8193 1A.1B.5C.22 Up S_AUTO_IF 10GE10/0/5 16391 8193 1A.1B.5C.30 Up S_AUTO_IF 10GE10/0/7 16392 0 1A.1B.5C.14 Down S_AUTO_IF 10GE10/0/3 -------------------------------------------------------------------------------- Total UP/DOWN Session Number : 6/1 |
步骤 2 查看BFD会话配置是正确的,查看BFD会话关联的对端I P 地址,有路由和ARP,能ping通:
BFD会话配置正确: # bfd 2 bind peer-ip 1A.1B.C.14 vpn-instance 1 interfa |