Linux vmware扩容无法识别

环境:Centos 7 + Vmware 6.7

问题:在vmeare 6.7 为centos 添加一块50g的硬盘用于扩容后,通过 echo "- - -" > /sys/class/scsi_host/host2/scan 等正常命令都无法识别到硬盘。通过fdisk -l 识别不到。

[root@localhost ~]# fdisk -l

Disk /dev/sda: 42.9 GB, 42949672960 bytes, 83886080 sectors

Units = sectors of 1 * 512 = 512 bytes

Sector size (logical/physical): 512 bytes / 512 bytes

I/O size (minimum/optimal): 512 bytes / 512 bytes

Disk label type: dos

Disk identifier: 0x000b5faf

Device Boot Start End Blocks Id System

/dev/sda1 * 2048 1026047 512000 83 Linux

/dev/sda2 1026048 83886079 41430016 8e Linux LVM

Disk /dev/sdb: 107.4 GB, 107374182400 bytes, 209715200 sectors

Units = sectors of 1 * 512 = 512 bytes

Sector size (logical/physical): 512 bytes / 512 bytes

I/O size (minimum/optimal): 512 bytes / 512 bytes

Disk /dev/mapper/centos-root: 139.6 GB, 139586437120 bytes, 272629760 sectors

Units = sectors of 1 * 512 = 512 bytes

Sector size (logical/physical): 512 bytes / 512 bytes

I/O size (minimum/optimal): 512 bytes / 512 bytes

Disk /dev/mapper/centos-swap: 1073 MB, 1073741824 bytes, 2097152 sectors

Units = sectors of 1 * 512 = 512 bytes

Sector size (logical/physical): 512 bytes / 512 bytes

I/O size (minimum/optimal): 512 bytes / 512 bytes

Disk /dev/mapper/centos-home: 9130 MB, 9130999808 bytes, 17833984 sectors

Units = sectors of 1 * 512 = 512 bytes

Sector size (logical/physical): 512 bytes / 512 bytes

I/O size (minimum/optimal): 512 bytes / 512 bytes

解决方法:

1 查看scsi

[root@localhost ~]# more /proc/scsi/scsi

Attached devices:

Host: scsi0 Channel: 00 Id: 00 Lun: 00

Vendor: VMware Model: Virtual disk Rev: 2.0

Type: Direct-Access ANSI SCSI revision: 06

Host: scsi0 Channel: 00 Id: 01 Lun: 00

Vendor: VMware Model: Virtual disk Rev: 2.0

Type: Direct-Access ANSI SCSI revision: 06

2 使用命令

 echo "scsi add-single-device 0 0 2 0">/proc/scsi/scsi

其中“0 0 2 0” 对应上 scsi0 00 02(01+1) 00 查看下图1 ,2

 

 

SCSI控制器0 SCSI0:2硬盘3

echo "scsi add-single-device 0 0 2 0">/proc/scsi/scsi

echo "scsi add-single-device x y z u"> /proc/scsi/scsi

x是硬盘或者磁带机所在SCSI控制器号;

y是硬盘或者磁带机所在SCSI通道的编号;

z是硬盘或者磁带机的SCSI ID号;

u是硬盘或者磁带机的lun号默认情况都是0

如果x y z参数不正确,系统是不能识别添加的硬盘和磁带机的可以通过 cat /proc/scsi/scsi命令来核实是否添加成功。

  • 0
    点赞
  • 2
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值