https://wenku.baidu.com/view/34d5723603768e9951e79b89680203d8cf2f6a4c.html
1、当CC1101进入SLEEP状态时,其PATABLE寄存器的数值,除了最低一个字节的数据之外,其余的7个字节的PATABLE设置值都将丢失这即是说,控制CC1101从SLEEP模式返回之后,需要再次重新设置PATABLE的数值。
2、工作一段时间不能工作,频率偏移。定期进行频率校准。既可以使用Strobe命令进行手动校准:SCAL,亦可在MCSM0.FS_AUTOCAL设置为1,然后在程序中设置:从IDLE转到RX或RT自动校准,重新进行频率校准。
The frequency synthesizer must be calibrated regularly. CC1101 has one manual calibration option (using the SCAL strobe), and three automatic calibration options that are controlled by the MCSM0.FS_AUTOCAL setting:
Calibrate when going from IDLE to either RX or TX (or FSTXON)
Calibrate when going from either RX or TX to IDLE automatically3
Calibrate every fourth time when going from either RX or TX to IDLE automatically3
If the radio goes from TX or RX to IDLE by issuing an SIDLE strobe, calibration will not be performed. The calibration takes a constant number of XOSC cycles; see Table 34 for timing details regarding calibration。