查看oracle多路径对应,显示多路径支持信息 - 在 Oracle® Solaris 11.2 中管理 SAN 设备和多路径...

显示多路径支持信息

可以使用 mpathadm 命令显示多路径支持信息并管理多路径搜索。多路径支持和属性信息用多路径管理 API 插件库名称进行标识,可使用 mpathadm 命令显示该插件库名称。

如何显示多路径支持信息成为管理员。

确定系统上的多路径支持。# mpathadm list mpath-support

mpath-support: libmpscsi_vhci.so

显示指定mpath 支持名称的多路径支持属性。# mpathadm show mpath-support libmpscsi_vhci.so

mpath-support: libmpscsi_vhci.so

Vendor: Sun Microsystems

Driver Name: scsi_vhci

Default Load Balance: round-robin

Supported Load Balance Types:

round-robin

logical-block

Allows To Activate Target Port Group Access: yes

Allows Path Override: no

Supported Auto Failback Config: yes

Auto Failback: on

Failback Polling Rate (current/max): 0/0

Supported Auto Probing Config: 0

Auto Probing: NA

Probing Polling Rate (current/max): NA/NA

Supported Devices:

Vendor: SUN

Product: T300

Revision:

Supported Load Balance Types:

round-robin

Vendor: SUN

Product: T4

Revision:

Supported Load Balance Types:

round-robin

.

.

.

命令输出还会显示多路径支持软件支持的设备产品的列表。缺省情况下,多路径支持 libmpscsi_vhci.so 库文件支持符合 T10 目标端口组的设备。

如何显示特定启动器端口的属性

以下步骤描述如何显示启动器端口的属性。

列出启动器端口。# mpathadm list initiator-port

Initiator Port: iqn.1986-03.com.sun:01:ffffffffffff.4e94f9bd,4000002a00ff

Initiator Port: 210100e08ba41feb

Initiator Port: 210000e08b841feb

显示特定启动器端口的属性。

# mpathadm show initiator-port 2000000173018713

Initiator Port: 210100e08ba41feb

Transport Type: Fibre Channel

OS Device File: /devices/pci@1,0/pci1022,7450@1/pci1077,141@2,1/fp@0,0

如果不使用 mpathadm show initiator-port 命令指定启动器端口,则将显示所有发现的启动器端口的属性。

如何显示特定 LU 信息

使用 mpathadm 命令显示 LU 列表以及每个 LU 的属性。显示的 LU 列表中又包含可用于显示特定 LU 的属性的名称。

显示多路径 LU 的列表。# mpathadm list lu

/dev/rdsk/c0t600144F08069703400004E828EE10004d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600144F08069703400004E8183DF0002d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800026D63A0000A4984E234298d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800029065C00007CF44E233FCFd0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800026D63A0000A4974E23424Ed0s2

Total Path Count: 4

Operational Path Count: 4

.

.

.

显示使用列表中 LU 名称的特定 LU 的配置信息。

# mpathadm show lu /dev/rdsk/c4t60003BA27D2120004204AC2B000DAB00d0s2

mpath-support: libmpscsi_vhci.so

Vendor: SUN

Product: Sun Storage NAS

Revision: 1.0

Name Type: unknown type

Name: 600144f08069703400004e828ee10004

Asymmetric: yes

Current Load Balance: round-robin

Logical Unit Group ID: NA

Auto Failback: on

Auto Probing: NA

Paths:

Initiator Port Name: 210100e08ba41feb

Target Port Name: 2100001b329b6c3f

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210100e08ba41feb

Target Port Name: 2101001b32bb6c3f

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210100e08ba41feb

Target Port Name: 2100001b329b793c

Override Path: NA

Path State: OK

Disabled: no

.

.

.

Target Port Groups:

ID: 0

Explicit Failover: no

Access State: active optimized

Target Ports:

Name: 2100001b329b6c3f

Relative ID: 1

Name: 2101001b32bb6c3f

Relative ID: 2

ID: 1

Explicit Failover: no

Access State: standby

Target Ports:

Name: 2100001b329b793c

Relative ID: 257

Name: 2101001b32bb793c

Relative ID: 256

如果不使用 mpathadm show lu 命令指定 LU 名称,则将显示有关所有发现的逻辑单元的信息。

如何显示与特定目标端口相关联的所有 LU

使用以下步骤显示通过目标端口的路径。

显示 LU 列表。# mpathadm list lu

/dev/rdsk/c0t600144F08069703400004E828EE10004d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600144F08069703400004E8183DF0002d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

Total Path Count: 4

Operational Path Count: 4

.

.

.

显示特定 LU 的信息,以确定目标端口。# mpathadm show lu /dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

Logical Unit: /dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

mpath-support: libmpscsi_vhci.so

Vendor: SUN

Product: CSM200_R

Revision: 0660

Name Type: unknown type

Name: 600a0b800029065c00007cf54e234013

Asymmetric: yes

Current Load Balance: round-robin

Logical Unit Group ID: NA

Auto Failback: on

Auto Probing: NA

Paths:

Initiator Port Name: 210000e08b841feb

Target Port Name: 200800a0b826d63b

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210000e08b841feb

Target Port Name: 200900a0b826d63b

Override Path: NA

Path State: OK

Disabled: no

.

.

.

Target Port Groups:

ID: 4

Explicit Failover: yes

Access State: standby

Target Ports:

Name: 200800a0b826d63b

Relative ID: 0

Name: 200800a0b826d63c

Relative ID: 0

ID: 14

Explicit Failover: yes

Access State: active

Target Ports:

Name: 200900a0b826d63b

Relative ID: 0

Name: 200900a0b826d63c

Relative ID: 0

显示特定的目标端口信息。# mpathadm list lu -t 20030003ba27d212

mpath-support: libmpscsi_vhci.so

/dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Total Path Count: 4

Operational Path Count: 4

mpath-support: libmpscsi_vhci.so

/dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

Total Path Count: 4

Operational Path Count: 4

mpath-support: libmpscsi_vhci.so

/dev/rdsk/c0t600A0B800026D63A0000A4984E234298d0s2

Total Path Count: 4

Operational Path Count: 4

mpath-support: libmpscsi_vhci.so

/dev/rdsk/c0t600A0B800029065C00007CF44E233FCFd0s2

Total Path Count: 4

Operational Path Count: 4

.

.

.

如何显示特定名称的 LU

显示有关多路径 LU 的详细信息,包括路径和目标端口组信息。请注意,信息中的名称属性表示该 LU 的标识符,它是从硬件派生出来的,并由该系统使用。如果此名称源自 SCSI Inquiry 重要产品数据 (Vital Product Data, VPD) 页面 83h,则名称类型属性表示 SCSI 标准定义的一个关联标识符类型。

显示多路径 LU 的列表。# mpathadm list lu

/dev/rdsk/c0t600144F08069703400004E828EE10004d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600144F08069703400004E8183DF0002d0s2

Total Path Count: 8

Operational Path Count: 8

/dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800029065C00007CF54E234013d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800026D63A0000A4984E234298d0s2

Total Path Count: 4

Operational Path Count: 4

/dev/rdsk/c0t600A0B800029065C00007CF44E233FCFd0s2

Total Path Count: 4

Operational Path Count: 4

.

.

.

显示选定 LU 的配置信息。

# mpathadm show lu /dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Logical Unit: /dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

mpath-support: libmpscsi_vhci.so

Vendor: SUN

Product: CSM200_R

Revision: 0660

Name Type: unknown type

Name: 600a0b800026d63a0000a4994e2342d4

Asymmetric: yes

Current Load Balance: round-robin

Logical Unit Group ID: NA

Auto Failback: on

Auto Probing: NA

Paths:

Initiator Port Name: 210000e08b841feb

Target Port Name: 200800a0b826d63b

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210000e08b841feb

Target Port Name: 200900a0b826d63b

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210000e08b841feb

Target Port Name: 200800a0b826d63c

Override Path: NA

Path State: OK

Disabled: no

Initiator Port Name: 210000e08b841feb

Target Port Name: 200900a0b826d63c

Override Path: NA

Path State: OK

Disabled: no

Target Port Groups:

ID: 3

Explicit Failover: yes

Access State: active

Target Ports:

Name: 200800a0b826d63b

Relative ID: 0

Name: 200800a0b826d63c

Relative ID: 0

ID: 13

Explicit Failover: yes

Access State: standby

Target Ports:

Name: 200900a0b826d63b

Relative ID: 0

Name: 200900a0b826d63c

Relative ID: 0

可以使用 mpathadm show lu 命令指定 –e 或 –-path-missing 选项以仅显示缺少的路径的逻辑单元。

显示选定 LU 的信息。# mpathadm list lu -n 600a0b800026d63a0000a4994e2342d4

mpath-support: libmpscsi_vhci.so

/dev/rdsk/c0t600A0B800026D63A0000A4994E2342D4d0s2

Total Path Count: 4

Operational Path Count: 4

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值