unsigned
long
long
GetCPUTickCount(){
unsigned long high32 = 0 , low32 = 0 ;
#ifdef WIN32 // WIN32
_asm
{
RDTSC;
mov high32,ebx;
mov low32,eax;
}
#else
__asm__ ( " RDTSC " : " =a " (low32), " =d " (high32));
#endif
unsigned long long counter = high32;
counter = (counter << 32 ) + low32;
return counter;
}
unsigned long high32 = 0 , low32 = 0 ;
#ifdef WIN32 // WIN32
_asm
{
RDTSC;
mov high32,ebx;
mov low32,eax;
}
#else
__asm__ ( " RDTSC " : " =a " (low32), " =d " (high32));
#endif
unsigned long long counter = high32;
counter = (counter << 32 ) + low32;
return counter;
}
//说明:RDTSC (就是ReaD TimeStamp Count) 其精度可以达到ns(纳秒)级别。(准确地说,其精度是1/F,F为你的CPU的时钟频率,这也是极限精度了)
//备注:RDTSC指令的机器码为 0x0F 0x31
inline __int64 RDTSC()
{
__int64 TimeStamp;
unsigned long highDword;
unsigned long lowDword;
__asm
{
rdtsc;
//也可以如下这样直接嵌入机器码
//_emit 0x0F;
//_emit 0x31;
mov highDword,ebx;
mov lowDword,eax;
}
TimeStamp = highDword;
TimeStamp <<= 32;
TimeStamp |= lowDword;
return TimeStamp;
}
RDTSC汇编指令用于程序的精确定时。原理是CPU从上电开始,其内部一个64位计数器就会记录下CPU所经过的周期数,RDTSC指令可以读取该计数器到寄存器EDX:EAX中。理论上计数精度可以达到纳秒级别。
不过在多核CPU平台上使用时发现,两个CPU核的内部计数器不同步。如果程序两次读取这个计数器的时候恰好被轮换到不同的核上,那么用来计时就会有比较大的误差。