wince -- RS485半双工实现

RS485半双工软件编程实现
 
方法 1 :让操作系统正确的控制 RTS 信号。
hCOM = CreateFile(...)
...
DCB dcb;
memset( &dcb, 0, sizeof(dcb) );
dcb.DCBlength = sizeof(DCB);
dcb.fBinary = TRUE; // binary mode, no EOF check
dcb.fParity = FALSE; // enable/disable parity checking
dcb.fOutxCtsFlow = FALSE; // CTS output flow control
dcb.fOutxDsrFlow = FALSE; // DSR output flow control
dcb.fDtrControl = DTR_CONTROL_DISABLE; // DTR flow control type DTR_CONTROL_HANDSHAKE;
dcb.fDsrSensitivity = FALSE; // DSR sensitivity
dcb.fTXContinueOnXoff = FALSE; // XOFF continues Tx
dcb.fOutX = FALSE; // XON/XOFF out flow control
dcb.fInX = FALSE; // XON/XOFF in flow control
dcb.fErrorChar = FALSE; // enable error replacement
dcb.fNull = FALSE; // enable null stripping
dcb.fAbortOnError = FALSE; // abort on error
dcb.BaudRate = ...; // current baud rate
dcb.ByteSize = ...; // number of bits/byte, 4-8
dcb.Parity = ...; // 0-4=no,odd,even,mark,space
dcb.StopBits = ...; // 0,1,2 = 1, 1.5, 2
dcb.fRtsControl = RTS_CONTROL_TOGGLE; // 关键啊,什么意思请参考MSDN
SetCommState( hCOM, &dcb );
...
然后就可以使用 ReadFile/WriteFile 执行 RS485 的收发了。
方法 2: 人工控制。当有特殊要求,不能采用系统控制时采用。
2.a) 空闲时,让串口进入接收状态。必须使用 ComSend 代替 WriteFile
dcb.fRtsControl = RTS_CONTROL_DISABLE;// 关键啊,什么意思请参考 MSDN
SetCommState( hCOM, &dcb );
int ComSend( HANDLE hCOM, const void* pBuf, int iBufSize )
{
EscapeCommFunction( hCOM, SETRTS );
WriteFile(...)
EscapeCommFunction( hCOM, CLRRTS )
...
}
2.b) 空闲时,让串口进入发送发送状态,进入接收状态时清除 RTS ,退出接收状态时设置 RTS
这种流程要复杂一些,有这种要求的不多吧?自己参照上面的办法去做吧。
使用以上这些办法,完全可以兼容 3 5 7 9 线制 232 485,422 ,软件不用关心串口的工作模式。
最后,如果板子上的 485 发送、接收使能没有连到 RTS 上,你可得向卖板子的问清楚,如何设置这些使能端。否则,你就是改驱动,也无从下手啊。
 