mysqls压力测试怎么用_老外讲仪表52用fluke 754 测试压力变送器

戳上面蓝字关注我们,免费获取联锁逻辑图绘制软件SmartCtrlLogic

翻译/制作:项阳

原文/译文:

测试压力变送器

Testing a pressure transmitter

咱们一起来过一下如何使用Fluke 754

Let's go through how to calibrate a pressure transmitter 

文档化过程校验仪来标定压力变送器

using the Fluke 754 documenting process calibrator 

在这个例子中

In this example 

我们将测量压力变送器发出的毫安信号

we're going to measure the mA signal drawn by the pressure transmitter 

并用内部回路电源为其供电

as well as powering it with an internal loop power supply 

我们将用手泵加压

We're going to generate pressure with the hand pump 

给Fluke压力模块

into the Fluke pressure module

这个模块连接到压力变送器的输入

which is also then connected to the input of the pressure transmitter 

初始化实验,我们要测量电流

To initiate the test we want to measure mA

打开回路电源

and turn on the loop power

下一步是配置输出为压力

Next step is to configure the source for pressure 

按压力

and pressure

对大气排空然后按下清零以防有任何电子偏移需要清零

vent to atmosphere and press clear zero in case there's any electronic offset to clear 

然后进到分屏模式来标定(同步显示测量与输出)

Next we go to the split-screen to do calibration 

按下“调整前校准”,选择仪表

Select As Found for an instrument 

我们将测量4-20mA

we're going to measure 4 to 20 mA 

公差0.5%

to test on 0.5% 

然后我们将输出0-100psi

and we're going to source 0 to 100 psi

做个3点测试

and we're going to do a three-point test

当我们选择手动测试,校验仪会告诉我们给多大的压力

When we select manual tests the calibrator will tell us the pressure to apply 

如果我们给了正确的压力,确认这个点

and if we have the correct pressure applied we accept that point 

现在校验仪让我给50psi

Now the calibrator asks me to go to 50 psi

关闭排空

I close the vent 

泵到50psi

and pump to 50 psi 

用微调来调整到压力值

use a fine adjust to dial in the pressure value

然后去到100psi

then go to 100 psi 

用微调来调整泵里的膜片到(要求)值

and use a fine adjust veneer in the pump to dial in the value 

确认这个值

accept that value 

(记录的测试结果)这是刚刚给定压力的测试后报告

Here's the post-test summary with the pressure that was applied 

测量到的电流

the mA that was measured 

量程的误差百分比

and the errors percent of span 

所有的误差百分比表明

all errors percent of span or ????  indicating 

这台压力变送器在实验允许的公差内

that the pressure transmitter was within the allowable test tolerance 

所以这台压力变送器通过了校验测试

so this pressure transmitter passes this calibration test

这就是如何用Fluke754文档化过程校验仪

That's how you verify the performance of a pressure transmitter 

来验证压力变送器的性能

using a fluke 754 documenting process calibrator

Fluke文档化过程校验仪:更快 更智能

Fluke Documenting Process Calibrators: Work faster. Work smarter.

7c3669f935ce0d89ace6f0c632b65492.png

评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值