linux查看文件句柄阀值,prometheus 告警指标

记录了prometheus 告警指标

主机和硬件监控

可用内存指标

主机中可用内存容量不足 10%

- alert: HostOutOfMemory

expr: node_memory_MemAvailable_bytes / node_memory_MemTotal_bytes * 100 < 10

for: 5m

labels:

severity: warning

annotations:

summary: Host out of memory (instance {{ $labels.instance }})

description: Node memory is filling up (< 10% left)

VALUE = {{ $value }}

LABELS: {{ $labels }}

内存

节点内存压力大。主要页面故障率高

- alert: HostMemoryUnderMemoryPressure

expr: rate(node_vmstat_pgmajfault[1m]) > 1000

for: 5m

labels:

severity: warning

annotations:

summary: Host memory under memory pressure (instance {{ $labels.instance }})

description: The node is under heavy memory pressure. High rate of major page faults

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机网络接口流入流量异常

主机网络接口可能接收了太多的数据(> 100 MB/s)。阀值根据自己机器背板网卡决定

- alert: HostUnusualNetworkThroughputIn

expr: sum by (instance) (rate(node_network_receive_bytes_total[2m])) / 1024 / 1024 > 100

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual network throughput in (instance {{ $labels.instance }})

description: Host network interfaces are probably receiving too much data (> 100 MB/s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机网络接口流出流量异常

主机网络接口可能发送了太多的数据(> 100 MB/s)。

- alert: HostUnusualNetworkThroughputOut

expr: sum by (instance) (rate(node_network_transmit_bytes_total[2m])) / 1024 / 1024 > 100

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual network throughput out (instance {{ $labels.instance }})

description: Host network interfaces are probably sending too much data (> 100 MB/s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机网络接收错误

{{ $labels.instance }}接口{{ ​$labels.device }}在过去5分钟内遇到{{ printf "%.0f" $value }}接收错误。

- alert: HostNetworkReceiveErrors

expr: increase(node_network_receive_errs_total[5m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host Network Receive Errors (instance {{ $labels.instance }})

description: {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} receive errors in the last five minutes.

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机网络传输错误

{{ $labels.instance }} 接口 {{ $labels.device }} 在过去五分钟内遇到 {{ printf "%.0f" $value }} 发送错误。

- alert: HostNetworkTransmitErrors

expr: increase(node_network_transmit_errs_total[5m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host Network Transmit Errors (instance {{ $labels.instance }})

description: {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf "%.0f" $value }} transmit errors in the last five minutes.

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机磁盘读速率

磁盘每秒读数据(> 50 MB/s)。

- alert: HostUnusualDiskReadRate

expr: sum by (instance) (rate(node_disk_read_bytes_total[2m])) / 1024 / 1024 > 50

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual disk read rate (instance {{ $labels.instance }})

description: Disk is probably reading too much data (> 50 MB/s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机磁盘写速率

磁盘每秒写数据

- alert: HostUnusualDiskWriteRate

expr: sum by (instance) (rate(node_disk_written_bytes_total[2m])) / 1024 / 1024 > 50

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual disk write rate (instance {{ $labels.instance }})

description: Disk is probably writing too much data (> 50 MB/s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机磁盘剩余空间

磁盘可用空间(<10% left)

# please add ignored mountpoints in node_exporter parameters like

# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)"

- alert: HostOutOfDiskSpace

expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10

for: 5m

labels:

severity: warning

annotations:

summary: Host out of disk space (instance {{ $labels.instance }})

description: Disk is almost full (< 10% left)

VALUE = {{ $value }}

LABELS: {{ $labels }}

根据磁盘目前的增长速度,在几个小时内是否会写满

根据当前一小时内磁盘增长量,判断磁盘在 4 个小时内会不会被写满

- alert: HostDiskWillFillIn4Hours

expr: predict_linear(node_filesystem_free_bytes{fstype!~"tmpfs"}[1h], 4 * 3600) < 0

for: 5m

labels:

severity: warning

annotations:

summary: Host disk will fill in 4 hours (instance {{ $labels.instance }})

description: Disk will fill in 4 hours at current write rate

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机中inode 文件句柄报警

磁盘可用的inode快用完了(<10%)。

- alert: HostOutOfInodes

expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint ="/rootfs"} * 100 < 10

for: 5m

labels:

severity: warning

annotations:

summary: Host out of inodes (instance {{ $labels.instance }})

description: Disk is almost running out of available inodes (< 10% left)

VALUE = {{ $value }}

LABELS: {{ $labels }}

磁盘读延迟

磁盘读取延迟大(读取操作>100ms)

- alert: HostUnusualDiskReadLatency

expr: rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual disk read latency (instance {{ $labels.instance }})

description: Disk latency is growing (read operations > 100ms)

VALUE = {{ $value }}

LABELS: {{ $labels }}

磁盘写入延迟大

磁盘写入延迟大(写操作>100ms)

- alert: HostUnusualDiskWriteLatency

expr: rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host unusual disk write latency (instance {{ $labels.instance }})

description: Disk latency is growing (write operations > 100ms)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机 cpu 负载高

cpu 负载大于 > 80%

- alert: HostHighCpuLoad

expr: 100 - (avg by(instance) (rate(node_cpu_seconds_total{mode="idle"}[5m])) * 100) > 80

for: 5m

labels:

severity: warning

annotations:

summary: Host high CPU load (instance {{ $labels.instance }})

description: CPU load is > 80%

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机上下文切换

上下文切换的节点越来越多(>1000/s)

# 1000 context switches is an arbitrary number.

# Alert threshold depends on nature of application.

# Please read: https://github.com/samber/awesome-prometheus-alerts/issues/58

- alert: HostContextSwitching

expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 1000

for: 5m

labels:

severity: warning

annotations:

summary: Host context switching (instance {{ $labels.instance }})

description: Context switching is growing on node (> 1000 / s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机 swap 分区使用

主机 swap 交换分区使用情况 (> 80%)

- alert: HostSwapIsFillingUp

expr: (1 - (node_memory_SwapFree_bytes / node_memory_SwapTotal_bytes)) * 100 > 80

for: 5m

labels:

severity: warning

annotations:

summary: Host swap is filling up (instance {{ $labels.instance }})

description: Swap is filling up (>80%)

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机 systemctl 管理的服务 down 了

主机上systemctl 管理的服务不正常,failed了,根据自己的实际情况来判断哪些服务

- alert: HostSystemdServiceCrashed

expr: node_systemd_unit_state{state="failed"} == 1

for: 5m

labels:

severity: warning

annotations:

summary: Host SystemD service crashed (instance {{ $labels.instance }})

description: SystemD service crashed

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机物理元设备(有的虚拟机可能没有此指标)

物理机温度过高

- alert: HostPhysicalComponentTooHot

expr: node_hwmon_temp_celsius > 75

for: 5m

labels:

severity: warning

annotations:

summary: Host physical component too hot (instance {{ $labels.instance }})

description: Physical hardware component too hot

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机节点超温报警(有的虚拟机可能没有此指标)

触发物理节点温度报警

- alert: HostNodeOvertemperatureAlarm

expr: node_hwmon_temp_alarm == 1

for: 5m

labels:

severity: critical

annotations:

summary: Host node overtemperature alarm (instance {{ $labels.instance }})

description: Physical node temperature alarm triggered

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机RAID 卡阵列失效(虚拟机可能没有此指标)

RAID阵列{{$labels.device }}由于一个或多个磁盘故障而处于退化状态。备用硬盘的数量不足以自动修复问题。

- alert: HostRaidArrayGotInactive

expr: node_md_state{state="inactive"} > 0

for: 5m

labels:

severity: critical

annotations:

summary: Host RAID array got inactive (instance {{ $labels.instance }})

description: RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机RAID磁盘故障(虚拟机可能没有此指标)

在{{ $labels.instance }} 的RAID阵列中至少有一个设备失败。阵列{{ $labels.md_device }}需要注意,可能需要进行磁盘更换

- alert: HostRaidDiskFailure

expr: node_md_disks{state="failed"} > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host RAID disk failure (instance {{ $labels.instance }})

description: At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap

VALUE = {{ $value }}

LABELS: {{ $labels }}

主机内核版本偏差

不同的内核版本正在运行

- alert: HostKernelVersionDeviations

expr: count(sum(label_replace(node_uname_info, "kernel", "$1", "release", "([0-9]+.[0-9]+.[0-9]+).*")) by (kernel)) > 1

for: 5m

labels:

severity: warning

annotations:

summary: Host kernel version deviations (instance {{ $labels.instance }})

description: Different kernel versions are running

VALUE = {{ $value }}

LABELS: {{ $labels }}

检测主机 OOM 杀进程

- alert: HostOomKillDetected

expr: increase(node_vmstat_oom_kill[5m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host OOM kill detected (instance {{ $labels.instance }})

description: OOM kill detected

VALUE = {{ $value }}

LABELS: {{ $labels }}

检测到主机EDAC可纠正的错误

{{ $labels.instance }}在过去5分钟内,EDAC报告了{{ printf "%.0f" $value }}可纠正的内存错误。

- alert: HostEdacCorrectableErrorsDetected

expr: increase(node_edac_correctable_errors_total[5m]) > 0

for: 5m

labels:

severity: info

annotations:

summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})

description: {{ $labels.instance }} has had {{ printf "%.0f" $value }} correctable memory errors reported by EDAC in the last 5 minutes.

VALUE = {{ $value }}

LABELS: {{ $labels }}

检测到主机EDAC不正确的错误

{{ $labels.instance }}在过去5分钟内,EDAC报告了{{ printf "%.0f" $value }}不可纠正的内存错误。

- alert: HostEdacUncorrectableErrorsDetected

expr: node_edac_uncorrectable_errors_total > 0

for: 5m

labels:

severity: warning

annotations:

summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})

description: {{ $labels.instance }} has had {{ printf "%.0f" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.

VALUE = {{ $value }}

LABELS: {{ $labels }}

Docker 容器

一个容器消失

- alert: ContainerKilled

expr: time() - container_last_seen > 60

for: 5m

labels:

severity: warning

annotations:

summary: Container killed (instance {{ $labels.instance }})

description: A container has disappeared

VALUE = {{ $value }}

LABELS: {{ $labels }}

容器 cpu 的使用量

容器CPU使用率超过80%。

# cAdvisor有时会消耗大量的CPU,所以这个警报会不断地响起。

# If you want to exclude it from this alert, just use: container_cpu_usage_seconds_total{name!=""}

- alert: ContainerCpuUsage

expr: (sum(rate(container_cpu_usage_seconds_total[3m])) BY (instance, name) * 100) > 80

for: 5m

labels:

severity: warning

annotations:

summary: Container CPU usage (instance {{ $labels.instance }})

description: Container CPU usage is above 80%

VALUE = {{ $value }}

LABELS: {{ $labels }}

容器内存的使用量

容器内存使用率超过 80%。

# See https://medium.com/faun/how-much-is-too-much-the-linux-oomkiller-and-used-memory-d32186f29c9d

- alert: ContainerMemoryUsage

expr: (sum(container_memory_working_set_bytes) BY (instance, name) / sum(container_spec_memory_limit_bytes > 0) BY (instance, name) * 100) > 80

for: 5m

labels:

severity: warning

annotations:

summary: Container Memory usage (instance {{ $labels.instance }})

description: Container Memory usage is above 80%

VALUE = {{ $value }}

LABELS: {{ $labels }}

容器磁盘的使用量

容器磁盘使用量超过 80%

- alert: ContainerVolumeUsage

expr: (1 - (sum(container_fs_inodes_free) BY (instance) / sum(container_fs_inodes_total) BY (instance)) * 100) > 80

for: 5m

labels:

severity: warning

annotations:

summary: Container Volume usage (instance {{ $labels.instance }})

description: Container Volume usage is above 80%

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis 相关报警信息

redis down

redis 服务 down 了,报警

- alert: RedisDown

expr: redis_up == 0

for: 5m

labels:

severity: critical

annotations:

summary: Redis down (instance {{ $labels.instance }})

description: Redis instance is down

VALUE = {{ $value }}

LABELS: {{ $labels }}

redis 缺少主节点(集群,或者sentinel 模式才有)

redis 集群中缺少标记的主节点

- alert: RedisMissingMaster

expr: (count(redis_instance_info{role="master"}) or vector(0)) < 1

for: 5m

labels:

severity: critical

annotations:

summary: Redis missing master (instance {{ $labels.instance }})

description: Redis cluster has no node marked as master.

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis 主节点过多

redis 集群中被标记的主节点过多

- alert: RedisTooManyMasters

expr: count(redis_instance_info{role="master"}) > 1

for: 5m

labels:

severity: critical

annotations:

summary: Redis too many masters (instance {{ $labels.instance }})

description: Redis cluster has too many nodes marked as master.

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis 复制中断

Redis实例丢失了一个slave

- alert: RedisReplicationBroken

expr: delta(redis_connected_slaves[1m]) < 0

for: 5m

labels:

severity: critical

annotations:

summary: Redis replication broken (instance {{ $labels.instance }})

description: Redis instance lost a slave

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis 集群 flapping

在Redis副本连接中检测到变化。当复制节点失去与主节点的连接并重新连接(也就是flapping)时,会发生这种情况。

- alert: RedisClusterFlapping

expr: changes(redis_connected_slaves[5m]) > 2

for: 5m

labels:

severity: critical

annotations:

summary: Redis cluster flapping (instance {{ $labels.instance }})

description: Changes have been detected in Redis replica connection. This can occur when replica nodes lose connection to the master and reconnect (a.k.a flapping).

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis缺少备份

Redis已经有24小时没有备份了。

- alert: RedisMissingBackup

expr: time() - redis_rdb_last_save_timestamp_seconds > 60 * 60 * 24

for: 5m

labels:

severity: critical

annotations:

summary: Redis missing backup (instance {{ $labels.instance }})

description: Redis has not been backuped for 24 hours

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis内存不足

Redis内存耗尽(>90%)。

#需要 redis 实例设置 maxmemory maxmemory-policy 最大使用内存参数

- alert: RedisOutOfMemory

expr: redis_memory_used_bytes / redis_total_system_memory_bytes * 100 > 90

for: 5m

labels:

severity: warning

annotations:

summary: Redis out of memory (instance {{ $labels.instance }})

description: Redis is running out of memory (> 90%)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis连接数过多

Redis实例有太多的连接

- alert: RedisTooManyConnections

expr: redis_connected_clients > 100

for: 5m

labels:

severity: warning

annotations:

summary: Redis too many connections (instance {{ $labels.instance }})

description: Redis instance has too many connections

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis连接数不足

Redis实例应该有更多的连接(> 5)。

- alert: RedisNotEnoughConnections

expr: redis_connected_clients < 5

for: 5m

labels:

severity: warning

annotations:

summary: Redis not enough connections (instance {{ $labels.instance }})

description: Redis instance should have more connections (> 5)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Redis拒绝连接

一些与Redis的连接已被拒绝

- alert: RedisRejectedConnections

expr: increase(redis_rejected_connections_total[1m]) > 0

for: 5m

labels:

severity: critical

annotations:

summary: Redis rejected connections (instance {{ $labels.instance }})

description: Some connections to Redis has been rejected

VALUE = {{ $value }}

LABELS: {{ $labels }}

rabbitmq 监控 : [rabbitmq/rabbitmq-prometheus ]

rabbitmq 节点 down

节点数量少于 1 个

- alert: RabbitmqNodeDown

expr: sum(rabbitmq_build_info) < 3

for: 5m

labels:

severity: critical

annotations:

summary: Rabbitmq node down (instance {{ $labels.instance }})

description: Less than 3 nodes running in RabbitMQ cluster

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqDown

expr: rabbitmq_up == 0

for: 5m

labels:

severity: critical

annotations:

summary: Rabbitmq down (instance {{ $labels.instance }})

description: RabbitMQ node down

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq实例的不同版本

在同一集群中运行不同版本的Rabbitmq,可能会导致失败。

- alert: RabbitmqInstancesDifferentVersions

expr: count(count(rabbitmq_build_info) by (rabbitmq_version)) > 1

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq instances different versions (instance {{ $labels.instance }})

description: Running different version of Rabbitmq in the same cluster, can lead to failure.

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqClusterPartition

expr: rabbitmq_partitions > 0

for: 5m

labels:

severity: critical

annotations:

summary: Rabbitmq cluster partition (instance {{ $labels.instance }})

description: Cluster partition

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq内存高

一个节点使用了90%以上的内存分配。

- alert: RabbitmqMemoryHigh

expr: rabbitmq_process_resident_memory_bytes / rabbitmq_resident_memory_limit_bytes * 100 > 90

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq memory high (instance {{ $labels.instance }})

description: A node use more than 90% of allocated RAM

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqOutOfMemory

expr: rabbitmq_node_mem_used / rabbitmq_node_mem_limit * 100 > 90

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq out of memory (instance {{ $labels.instance }})

description: Memory available for RabbmitMQ is low (< 10%)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq文件描述符的用法

一个节点使用90%以上的文件描述符。

- alert: RabbitmqFileDescriptorsUsage

expr: rabbitmq_process_open_fds / rabbitmq_process_max_fds * 100 > 90

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq file descriptors usage (instance {{ $labels.instance }})

description: A node use more than 90% of file descriptors

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqTooManyConnections

expr: rabbitmq_connectionsTotal > 1000

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq too many connections (instance {{ $labels.instance }})

description: RabbitMQ instance has too many connections (> 1000)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq连接数太多

节点的总连接数过高。

- alert: RabbitmqTooMuchConnections

expr: rabbitmq_connections > 1000

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq too much connections (instance {{ $labels.instance }})

description: The total connections of a node is too high

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqTooManyMessagesInQueue

expr: rabbitmq_queue_messages_ready{queue="my-queue"} > 1000

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq too many messages in queue (instance {{ $labels.instance }})

description: Queue is filling up (> 1000 msgs)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq无队列消费

一个队列的消费者少于1个

- alert: RabbitmqNoQueueConsumer

expr: rabbitmq_queue_consumers < 1

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq no queue consumer (instance {{ $labels.instance }})

description: A queue has less than 1 consumer

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqSlowQueueConsuming

expr: time() - rabbitmq_queue_head_message_timestamp{queue="my-queue"} > 60

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq slow queue consuming (instance {{ $labels.instance }})

description: Queue messages are consumed slowly (> 60s)

VALUE = {{ $value }}

LABELS: {{ $labels }}

Rabbitmq不可路由的消息

一个队列有不可更改的消息

- alert: RabbitmqUnroutableMessages

expr: increase(rabbitmq_channel_messages_unroutable_returned_total[5m]) > 0 or increase(rabbitmq_channel_messages_unroutable_dropped_total[5m]) > 0

for: 5m

labels:

severity: warning

annotations:

summary: Rabbitmq unroutable messages (instance {{ $labels.instance }})

description: A queue has unroutable messages

VALUE = {{ $value }}

LABELS: {{ $labels }} - alert: RabbitmqNoConsumer

expr: rabbitmq_queue_consumers == 0

for: 5m

labels:

severity: critical

annotations:

summary: Rabbitmq no consumer (instance {{ $labels.instance }})

description: Queue has no consumer

VALUE = {{ $value }}

LABELS: {{ $labels }}

### 回答1: 要查看Linux系统中打开的文件句柄数,可以使用以下命令: ``` $ cat /proc/sys/fs/file-nr ``` 该命令会输出三个数字,分别表示当前已分配的文件句柄数、当前已使用的文件句柄数和系统最大允许的文件句柄数。其中,第一个数字表示已分配但未使用的文件句柄数,第二个数字表示已经使用的文件句柄数,第三个数字表示系统最大允许的文件句柄数。 ### 回答2: 在Linux中,每个进程都有一个默认的文件句柄限制,用于限制进程能够打开的文件数量。如果进程试图打开超过这个限制的文件,则会收到一个错误。在大多数情况下,这个限制被设置为1024个文件句柄,但是根据系统配置的不同,它也可能更高或更低。 在Linux中,可以使用许多不同的命令来检查当前的文件句柄限制和进程打开的文件句柄数。以下是一些最常见的命令: 1. ulimit命令 ulimit是一个用于控制操作系统资源限制的命令,包括文件句柄限制。默认情况下,ulimit -n命令将显示进程的文件句柄限制。要查看当前进程已经打开的文件句柄数,可以使用lsof命令。 2. /proc/sys/fs/file-max文件 /proc/sys/fs/file-max是一个包含系统文件句柄数的文件。这个值表示系统上允许的最大文件句柄数。要查看这个值,可以使用cat /proc/sys/fs/file-max命令。 3. lsof命令 lsof命令可以列出当前进程打开的文件和网络连接。可以使用以下命令来列出当前进程打开的文件数: lsof -u username | wc -l 其中,username是进程所有者的用户名。这将返回打开的文件数。 4. ss命令 ss命令用于列出所有活动的套接字连接。可以使用以下命令来列出所有进程的文件句柄数: ss -s 这将返回所有进程当前打开的文件句柄数量。 总的来说,在Linux查看文件句柄数可以使用既定的命令,如ulimit、/proc/sys/fs/file-max、lsof和ss等,但要注意选择合适的命令来查看所需的信息。 ### 回答3: 在Linux系统中,文件句柄数是指进程能够保持的打开文件的数量。每个进程在运行时都会分配一定数量的文件句柄,而每次使用文件时,进程都会使用其中的一个句柄来表示该文件。如果该进程打开了过多的文件,就可能会导致文件句柄耗尽,从而无法打开更多的文件。 要查看Linux系统中的文件句柄数,可以使用以下命令: 1. 查看当前用户的文件句柄数: 命令:ulimit -n 该命令将显示当前用户可以打开的文件句柄数。如果该值为默认值,则通常为1024。如果需要增加文件句柄数,可以编辑/etc/security/limits.conf文件并添加以下行: * soft nofile 65535 * hard nofile 65535 这将允许所有用户同时打开多达65535个文件。 2. 查看某个进程的文件句柄数: 命令:lsof -p <pid> | wc -l 该命令将显示指定进程的文件句柄数。要查找特定进程的PID,请使用ps或top命令。 3. 查看系统中所有进程的文件句柄数: 命令:cat /proc/sys/fs/file-nr 该命令将显示系统中所有进程使用的文件句柄数,以及系统可以分配的最大文件句柄数。这个值应该是当前文件句柄数和文件句柄限制之间的最小值。如果当前的文件句柄数接近最大数量,则可能需要增加文件句柄的限制。 总之,要查看Linux系统中的文件句柄数,可以使用ulimit、lsof和cat等命令。了解文件句柄数的数量对于确保系统的稳定性和可靠性非常重要。
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值