hp580g7安装linux,HP Proliant DL580 G5安装centos7 x64无法识别阵列卡问题

1、进入安装光盘,用上下键选择安装centos——Install Centos7(注意不可按Enter键),如图:

2、按Tab键,对安装进行额外配置,在屏幕最下方会显示如下字样:

3、在额外配置的命令行上添加配置: hpsa.hpsa_simple_mode=1 hpsa.hpsa_allow_any=1,如图所示:

4、按回车继续安装

经过以上几步,安装程序即可识别出HP服务器的硬盘。

参考:

http://serverfault.com/questions/611182/centos-7-x64-and-hp-proliant-dl360-g5-scsi-controller-compatibility

https://www.centos.org/forums/viewtopic.php?f=49&t=47011

So the HP RAID controller driver from around 2001 to ~2009 was the CCISS driver. There was a transition to the HPSA driver at some point, moving the Smart Array controller support back into the regular SCSI subsystem versus the dedicated block driver...

HP servers from the G1 to G5 era used the CCISS driver. On newer operating systems (EL6 and forward), HP ProLiant G6 and newer systems made use of the HPSA driver.