我们在纱线上运行的 生产环境 流工作中运行自定义指标,如米,计 .
以下是步骤:
对pom.xml的额外依赖
org.apache.flink
flink-metrics-dropwizard
${flink.version}
我们使用的是1.2.1版
然后将meter添加到MyMapper类 .
import org.apache.flink.api.common.JobExecutionResult;
import org.apache.flink.api.common.functions.RichMapFunction;
import org.apache.flink.configuration.Configuration;
import org.apache.flink.dropwizard.metrics.DropwizardMeterWrapper;
import org.apache.flink.metrics.Meter;
import org.apache.flink.streaming.api.environment.StreamExecutionEnvironment;
public class Test {
public static void main(String[] args) throws Exception {
StreamExecutionEnvironment env = StreamExecutionEnvironment.getExecutionEnvironment();
env
.readTextFile("/home/LizardKing/Documents/Power/Prova.csv")
.map(new MyMapper())
.writeAsCsv("/home/LizardKing/Results.csv");
JobExecutionResult res = env.execute();
}
private static class MyMapper extends RichMapFunction {
private transient Meter meter;
@Override
public void open(Configuration parameters) throws Exception {
super.open(parameters);
this.meter = getRuntimeContext()
.getMetricGroup()
.meter("myMeter", new DropwizardMeterWrapper(new com.codahale.metrics.Meter()));
}
@Override
public Object map(String value) throws Exception {
this.meter.markEvent();
return value;
}
}
}
希望这可以帮助 .