服务器t610硬盘型号,已解决: RE: T610服务器硬盘亮橙色灯,换了新硬盘问题无法解决。附上日志。 - Dell Community...

个人觉得虽然在另的服务器上检测到,但不代表就是背板的问题,可以的情况下有其它硬盘可以接在T610上重建阵列先看看,根据以下日志,硬盘接上后,一直在检测超时,所以先找硬盘重建尝试先。

另假设更换背板,数据不会丢失,数据是保存的硬盘里面的,不是在背板。但以防万一建议在做任何操作前备份好数据。

02/28/17 14:43:44: SES_MarkBadElement: enclPd 20 timeDiff cfc4c slot 5 badElmt 1 retryCnt 0 oldTime:0 currentTime:cfc4c

02/28/17 14:43:54: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:43:54: SES_MarkBadElement: enclPd 20 timeDiff a slot 5 badElmt 1 retryCnt 1 oldTime:cfc4c currentTime:cfc56

02/28/17 14:44:04: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:04: SES_MarkBadElement: enclPd 20 timeDiff 14 slot 5 badElmt 1 retryCnt 1 oldTime:cfc4c currentTime:cfc60

02/28/17 14:44:14: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:14: SES_MarkBadElement: enclPd 20 timeDiff 1e slot 5 badElmt 1 retryCnt 1 oldTime:cfc4c currentTime:cfc6a

02/28/17 14:44:24: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:24: SES_MarkBadElement: enclPd 20 timeDiff 28 slot 5 badElmt 1 retryCnt 1 oldTime:cfc4c currentTime:cfc74

02/28/17 14:44:34: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:34: SES_MarkBadElement: enclPd 20 timeDiff a slot 5 badElmt 1 retryCnt 2 oldTime:cfc74 currentTime:cfc7e

02/28/17 14:44:44: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:44: SES_MarkBadElement: enclPd 20 timeDiff 14 slot 5 badElmt 1 retryCnt 2 oldTime:cfc74 currentTime:cfc88

02/28/17 14:44:54: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:44:54: SES_MarkBadElement: enclPd 20 timeDiff 1e slot 5 badElmt 1 retryCnt 2 oldTime:cfc74 currentTime:cfc92

02/28/17 14:45:04: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:45:04: SES_MarkBadElement: enclPd 20 timeDiff 28 slot 5 badElmt 1 retryCnt 2 oldTime:cfc74 currentTime:cfc9c

02/28/17 14:45:14: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:45:14: SES_MarkBadElement: enclPd 20 timeDiff a slot 5 badElmt 1 retryCnt 3 oldTime:cfc9c currentTime:cfca6

02/28/17 14:45:24: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:45:24: SES_MarkBadElement: enclPd 20 timeDiff 14 slot 5 badElmt 1 retryCnt 3 oldTime:cfc9c currentTime:cfcb0

02/28/17 14:45:34: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:45:34: SES_MarkBadElement: enclPd 20 timeDiff 1e slot 5 badElmt 1 retryCnt 3 oldTime:cfc9c currentTime:cfcba

02/28/17 14:45:44: SES_BackplaneMapping: Un-Associated device on enclPd 20 StsCode = 6 elmtType 17 elmtIndex 5 slotPd =5 SasAddr =0

02/28/17 14:45:44: SES_MarkBadElement: enclPd 20 timeDiff 28 slot 5 badElmt 1 retryCnt 3 oldTime:cfc9c currentTime:cfcc4

02/28/17 14:45:44: EVT#61471-02/28/17 14:45:44: 185=Enclosure PD 20(c None/p0) phy bad for slot 5