1.服务器raid配置
服务器raid配置,磁盘固态双盘坐raid1,数据盘机械盘三块做raid5 ,系统盘和数据盘分开
2.系统镜像下载
https://www.dell.com/support/home/zh-cn/product-support/product/poweredge-r740/drivers
VMware-VMvisor-Installer-7.0.0.update03-23307199.x86_64-Dell_Customized-A21.iso
下载链接:
3.U盘制作
推荐使用rufus或者ventoy,或者是试用dell虚拟机控制台挂载iso安装
启动按f11,选择U盘引导即可
4安装出现的错误及解决
CRC error during deconpression. ReceivedBPPOFCRC(0x9554a3b6)
g2ip_cxtract failed for /k.b00(size 0):
CRC errOIiror 28 (CRC error)while loading module:
/k.b00Compressed
MD5:1da422650be66772ffbec9ba8c94439abieconpressedMD5
:00000000000000000000000000000000
Fatal error : 28 (CRC error)
更换镜像后,更换制作工具,仍出现错误,每次都是不同的文件报错
error 33 (Inconsistent data)while decompressing data
input(38816725),output(33806620)
g2ip extract failed for /vmx.v00 (size 33816742):
Inconsistent data Error 33(Inconsistent data)
while loading module:/vmx.v00
Conpressed
MD5:1e136cfc26d12e5bfe28619655563616Deconpressed
MD5:00000000000000000000000000000000
Fatal error : 33 (Inconsistent data)
google搜索后发现一个帖子如下
报错原因可能是镜像源出错,或者是U盘故障,更换U盘和试用虚拟远程控制台挂载虚拟镜像后安装正常。
4.dell虚拟控制台试用许可
根据自己的机型,下载后后导入许可,远程后挂载iso进行安装即可。
安装完毕。