Today, I upgraded my jenkins server from 1.6 to 2.7, then I visited the http://jenkins:8080
. I gave me “connection refused” error.
I checked the /var/log/jenkins/jenkins.log
, it has:
SEVERE: Container startup failed
java.io.IOException: Failed to start a listener: winstone.Ajp13ConnectorFactory
at winstone.Launcher.spawnListener(Launcher.java:207)
at winstone.Launcher.<init>(Launcher.java:148)
at winstone.Launcher.main(Launcher.java:352)
at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
at sun.reflect.NativeMethodAccessorImpl.invoke(NativeMethodAccessorImpl.java:62)
at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java:43)
at java.lang.reflect.Method.invoke(Method.java:498)
at Main._main(Main.java:246)
at Main.main(Main.java:91)
Caused by: java.lang.UnsupportedOperationException: AJP support is removed in Winstone 3.0 due to Jetty 9 not supporting AJP.For reverse proxying, please use HTTP instead of AJP.
at winstone.Ajp13ConnectorFactory.start(Ajp13ConnectorFactory.java:31)
at winstone.Launcher.spawnListener(Launcher.java:205)
... 8 more
I googled around and found this article that solve the problem.
Long story short, setting JENKINS_AJP_PORT="-1"
in /etc/sysconfig/jenkins
solved problem.