Kei C51 编译出来的hex文件分析

参考:https://blog.csdn.net/wyq_841943/article/details/71404547

分析这个工程:
startup.a51

$NOMOD51
;------------------------------------------------------------------------------
;  This file is part of the C51 Compiler package
;  Copyright (c) 1988-2005 Keil Elektronik GmbH and Keil Software, Inc.
;  Version 8.01
;
;  *** <<< Use Configuration Wizard in Context Menu >>> ***
;------------------------------------------------------------------------------
;  STARTUP.A51:  This code is executed after processor reset.
;
;  To translate this file use A51 with the following invocation:
;
;     A51 STARTUP.A51
;
;  To link the modified STARTUP.OBJ file to your application use the following
;  Lx51 invocation:
;
;     Lx51 your object file list, STARTUP.OBJ  controls
;
;------------------------------------------------------------------------------
;
;  User-defined <h> Power-On Initialization of Memory
;
;  With the following EQU statements the initialization of memory
;  at processor reset can be defined:
;
; <o> IDATALEN: IDATA memory size <0x0-0x100>
;     <i> Note: The absolute start-address of IDATA memory is always 0
;     <i>       The IDATA space overlaps physically the DATA and BIT areas.
IDATALEN        EQU     80H
;
; <o> XDATASTART: XDATA memory start address <0x0-0xFFFF> 
;     <i> The absolute start address of XDATA memory
XDATASTART      EQU     0     
;
; <o> XDATALEN: XDATA memory size <0x0-0xFFFF> 
;     <i> The length of XDATA memory in bytes.
XDATALEN        EQU     0      
;
; <o> PDATASTART: PDATA memory start address <0x0-0xFFFF> 
;     <i> The absolute start address of PDATA memory
PDATASTART      EQU     0H
;
; <o> PDATALEN: PDATA memory size <0x0-0xFF> 
;     <i> The length of PDATA memory in bytes.
PDATALEN        EQU     0H
;
;</h>
;------------------------------------------------------------------------------
;
;<h> Reentrant Stack Initialization
;
;  The following EQU statements define the stack pointer for reentrant
;  functions and initialized it:
;
; <h> Stack Space for reentrant functions in the SMALL model.
;  <q> IBPSTACK: Enable SMALL model reentrant stack
;     <i> Stack space for reentrant functions in the SMALL model.
IBPSTACK        EQU     0       ; set to 1 if small reentrant is used.
;  <o> IBPSTACKTOP: End address of SMALL model stack <0x0-0xFF>
;     <i> Set the top of the stack to the highest location.
IBPSTACKTOP     EQU     0xFF +1     ; default 0FFH+1  
; </h>
;
; <h> Stack Space for reentrant functions in the LARGE model.      
;  <q> XBPSTACK: Enable LARGE model reentrant stack
;     <i> Stack space for reentrant functions in the LARGE model.
XBPSTACK        EQU     0       ; set to 1 if large reentrant is used.
;  <o> XBPSTACKTOP: End address of LARGE model stack <0x0-0xFFFF>
;     <i> Set the top of the stack to the highest location.
XBPSTACKTOP     EQU     0xFFFF +1   ; default 0FFFFH+1 
; </h>
;
; <h> Stack Space for reentrant functions in the COMPACT model.    
;  <q> PBPSTACK: Enable COMPACT model reentrant stack
;     <i> Stack space for reentrant functions in the COMPACT model.
PBPSTACK        EQU     0       ; set to 1 if compact reentrant is used.
;
;   <o> PBPSTACKTOP: End address of COMPACT model stack <0x0-0xFFFF>
;     <i> Set the top of the stack to the highest location.
PBPSTACKTOP     EQU     0xFF +1     ; default 0FFH+1  
; </h>
;</h>
;------------------------------------------------------------------------------
;
;  Memory Page for Using the Compact Model with 64 KByte xdata RAM
;  <e>Compact Model Page Definition
;
;  <i>Define the XDATA page used for PDATA variables. 
;  <i>PPAGE must conform with the PPAGE set in the linker invocation.
;
; Enable pdata memory page initalization
PPAGEENABLE     EQU     0       ; set to 1 if pdata object are used.
;
; <o> PPAGE number <0x0-0xFF> 
; <i> uppermost 256-byte address of the page used for PDATA variables.
PPAGE           EQU     0
;
; <o> SFR address which supplies uppermost address byte <0x0-0xFF> 
; <i> most 8051 variants use P2 as uppermost address byte
PPAGE_SFR       DATA    0A0H
;
; </e>
;------------------------------------------------------------------------------

; Standard SFR Symbols 
ACC     DATA    0E0H
B       DATA    0F0H
SP      DATA    81H
DPL     DATA    82H
DPH     DATA    83H

                NAME    ?C_STARTUP


?C_C51STARTUP   SEGMENT   CODE
?STACK          SEGMENT   IDATA

                RSEG    ?STACK
                DS      1

                EXTRN CODE (?C_START)
                PUBLIC  ?C_STARTUP

                CSEG    AT      0
?C_STARTUP:     LJMP    STARTUP1

                RSEG    ?C_C51STARTUP

STARTUP1:

IF IDATALEN <> 0
                MOV     R0,#IDATALEN - 1
                CLR     A
IDATALOOP:      MOV     @R0,A
                DJNZ    R0,IDATALOOP
ENDIF

IF XDATALEN <> 0
                MOV     DPTR,#XDATASTART
                MOV     R7,#LOW (XDATALEN)
  IF (LOW (XDATALEN)) <> 0
                MOV     R6,#(HIGH (XDATALEN)) +1
  ELSE
                MOV     R6,#HIGH (XDATALEN)
  ENDIF
                CLR     A
XDATALOOP:      MOVX    @DPTR,A
                INC     DPTR
                DJNZ    R7,XDATALOOP
                DJNZ    R6,XDATALOOP
ENDIF

IF PPAGEENABLE <> 0
                MOV     PPAGE_SFR,#PPAGE
ENDIF

IF PDATALEN <> 0
                MOV     R0,#LOW (PDATASTART)
                MOV     R7,#LOW (PDATALEN)
                CLR     A
PDATALOOP:      MOVX    @R0,A
                INC     R0
                DJNZ    R7,PDATALOOP
ENDIF

IF IBPSTACK <> 0
EXTRN DATA (?C_IBP)

                MOV     ?C_IBP,#LOW IBPSTACKTOP
ENDIF

IF XBPSTACK <> 0
EXTRN DATA (?C_XBP)

                MOV     ?C_XBP,#HIGH XBPSTACKTOP
                MOV     ?C_XBP+1,#LOW XBPSTACKTOP
ENDIF

IF PBPSTACK <> 0
EXTRN DATA (?C_PBP)
                MOV     ?C_PBP,#LOW PBPSTACKTOP
ENDIF

                MOV     SP,#?STACK-1

; This code is required if you use L51_BANK.A51 with Banking Mode 4
;<h> Code Banking
; <q> Select Bank 0 for L51_BANK.A51 Mode 4
#if 0   
;     <i> Initialize bank mechanism to code bank 0 when using L51_BANK.A51 with Banking Mode 4.
EXTRN CODE (?B_SWITCH0)
                CALL    ?B_SWITCH0      ; init bank mechanism to code bank 0
#endif
;</h>
                LJMP    ?C_START

                END
hello.c:
 

#include <reg51.h>


int main()
{
    unsigned char a = 0xf0 ;
    unsigned char b= 0x12 ;
    unsigned char c = a + b ;
    #pragma ASM
    mov A,P0
    mov A,#0
    Mov A,5
    Mov A,r0
    
    #pragma ENDASM
    return 0;
}

hex:
:03000000020811E2
:0C081100787FE4F6D8FD7581080208002D
:1008000074F02412F508E5807400E505E8E4FEFFC5
:0108100022C5
:00000001FF

 

 

Kei C51-L是一种支持Modbus通信协议的设备,它能够通过Modbus协议与其他设备进行数据交互。要实现Kei C51-L与CSDN上的设备进行Modbus通信,需要按照以下步骤操作: 第一步是准备工作,首先要确保Kei C51-L设备已经正确连接到CSDN上的设备,并且它们之间的通信线路已经连接好。同时,需要确保Kei C51-L设备的固件已经正确配置并支持Modbus通信协议。 第二步是在Kei C51-L设备上进行Modbus通信的配置。首先需要设置Modbus通信的参数,如波特率、数据位、停止位等。这些参数需要与CSDN上的设备相匹配。然后,需要配置Kei C51-L设备的Modbus地址,这个地址用于区分不同的设备。 第三步是编写程序代码,通过Kei C51-L设备与CSDN上的设备进行Modbus通信。在代码中,需要使用相应的Modbus库函数来进行读写操作。例如,可以使用Modbus的读保持寄存器功能来读取CSDN上设备的数据,或使用写单个寄存器功能来向CSDN上的设备发送控制命令。 最后一步是测试和调试,可以通过模拟器或者实际设备进行通信测试,确保Kei C51-L设备与CSDN上的设备能够正常进行Modbus通信。如有问题,可以通过调试技术找到并解决通信问题。 总的来说,Kei C51-L设备要与CSDN上的设备进行Modbus通信,需要进行设备连接、配置参数、编写代码及测试等一系列操作。只有在正确配置和编写的情况下,两个设备才能成功进行Modbus通信。