A Way configures PMIC
Features
• Input voltage range: 3.8V to 23V (no dead zone)
• Output voltage: up to 21V
• Up to 1MHz switching frequency
• Pin programmable soft-start time
• LDO output for VDD and VDDP
• System FAULT status ALERT function
• Input/output internal discharge function
• Active switching for negative voltage transitions
• Pass Through mode in both directions
• Forward and Reverse mode enable pins
• OCP, OVP, UVP, and OTP protection
• Absolute overvoltage protection
• SMBus and auto-increment I2C compatible
Address table and define
Smbus protocol data format
PROG - design for default value
Rs1 and Rs2 define the System side voltage and current
Schematic
Desige table
- Setting System Side Current Limit
To set the system side current limit, which is the output current in Forward mode or the input current in Reverse
mode, write a 16-bit SystemCurrentLimit command (0x14H or 0b00010100) using the Write-word protocol.
The maximum value is clamped at 6080mA for Rs2 = 10mΩ.
SystemCurrentLimit Register 0x14H (11-Bit, 4mA Step, 10mΩ Sense Resistor)
The maximum value is clamped at 12160mA for Rs2 = 5mΩ.
SystemCurrentLimit Register 0x14H (11-Bit, 8mA Step, 5mΩ Sense Resistor)
-
Setting Input Current Limit in Forward Mode
To set the input current limit in Forward mode, write a 16-bit ForwardInputCurrent command (0x3FH or 0b00111111) using the Write-word protoco
The maximum values are clamped at 6080mA for Rs1 = 20mΩ.
ForwardInputCurrent Register 0x3FH (11-Bit, 4mA Step, 20mΩ Sense Resistor, x18)
The maximum values are clamped at 12160mA for Rs1 = 20mΩ.
ForwardInputCurrent Register 0x3FH (11-Bit, 8mA Step, 10mΩ Sense Resistor, x18)
- Control Registers
The Control0, Control1, Control2, Control3, and Control4 registers configure the RAA489800 operation. To
change certain functions or options after VDD 2.7V POR, write a 16-bit control command to
the Control0 register (0x39H or 0b00111001) ,
the Control1 register (0x3CH or 0b00111100) ,
the Control2 register (0x3DH or 0b00111101) ,
the Control3 register (0x4CH or 0b00111100) , and 8-bit control command to
the Control4 register (0x4EH or 0b00111101) using the Write-word protocol.
- Setting ALERT# Debounce Time
Control2 register Bit<10:9> configures the ALERT# signal debounce time before its assertion for the fault indicator response.
- Input Voltage Limit Register
The InputVoltageLimit register contains SMBus readable and writable input voltage limits. The default is 4.096V.
This register accepts any command, but only the valid register bits are written to the register. The maximum
values are clamped at 18V. The recommended minimum setting for this register is 4.096V.