PLC-ANALYZER连接S7-200SMART,进行变量监视的方法:

S7-200SMART CPU都有以太网接口,如何与PLC-ANALYZER相连,实现变量监视呢?步骤如下:

 

  1. 必须安装有STEP7接口组件,将 “Set PG/PC interface”中的S7ONLINE(STEP7)指定为与PLC相连的网卡:
  2. 在PLC-ANALYZER中选择S7 Industrial Ethernet TCP/IP driver;
  3. 在驱动中输入CPU的以太网地址,设置 “Slotnumber of CPU”为1;
  4. 如果选择V区,则需要映射到DB1,例如,记录VB3,则需要输入DB1.DBB3。也可以记录M区、I、Q区域。

以上是在WIN7 64位中的实现,其他系统应该类似。
 
注意:S7-200和SMART系列CPU只有一个编程器连接的资源(S7协议),因此,不能和编程软件同时在线。

 

还好:国内的专业录波软件PLC-Recorder已经上线了(hiddenmap.cn下载),可以对多种PLC进行数据连续采集(小、集成驱动、同时对多种PLC采集,可以部分替代PLC-ANALYZER,IBA等软件,免费功能很强大),适应XP到WIN10,不需要依赖西门子的任何软件和设置,只需要输入IP地址,即可直接访问V区变量,大家可以尝试一下。可以用于PLC协助调试、高级故障诊断、重要数据长期存档等。

  • 1
    点赞
  • 4
    收藏
    觉得还不错? 一键收藏
  • 0
    评论
西门子plc调试软件,功能强大。具体https://www.mhj-tools.com/winplc-analyzer/ 直接看网页。 先安装软件,然后用文件夹中的破解覆盖。本人亲自破解,只此一家。分数高了点。 With WinPLC-Analyzer you can record signals of a S7-PLC (S7-300, S7-400, S7-1200) or S5-PLC (Simatic S5 series). You can record signals like input, output, flags, data, timer and counter. If you want, you can define a Trigger with S7-STL code. Then you can use this trigger to control the recording or to create a user message. When using S7-300, S7-400 you can also record cyclic exact. This means, that a short program will be transfered into the PLC. This ensures that you see every single edge in the recording. Without modifying the PLC progam you can record "scan exact". That means you can define the sampling rate in ms. With the special recording type "Offline recording", you can record the data within the PLC (without the PC connected). The next day you can transfer the results to your WinPLC-Analyzer project. Additional to the normal trend data, you can define "Snapshots". A "Snapshot" is a range of additional data, that will be stored, if a trigger event is raised. WinPLC-Analyzer also stores the data of the "i-stack" in case of a unexpected "PLC-Stop". Then you can examine the reasons for the PLC-Stop even after days. All software driver are included in the licence of WinPLC-Analyzer. You don't have to pay for every single driver separatly. To access a PLC over TCP/IP you don't need any other software or driver. Only if you want to use a SIEMENS Interface, the driver of it must be installed on the PC.

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值