dell服务器错误代码汇总

 

Cable and Board Presence - Message Code: "x1Axx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1A10PDBPwrCableHighPDB power cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A11PCIRsrConfigHighPCI risers are not configured correctly; some invalid configurations prevent system power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A12PCIRsrMissingHighOne or all of the PCI risers is missing. This prevents system power on.Failing device is reseated/replaced/repaired.YesPre-Post
E1A14SAS Cable ALowSAS cable A is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A15SAS Cable BLowSAS cable B is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A16SAS Cable FBLowFlex bay SAS cable is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A17PwrCable FBLowFlex bay power cable is missing or bad.Failing device is reseated/replaced/repaired.YesAny
E1A18PDBCtrl CableHighPDB control cable to the planar is missing or bad and system will not power on.Failing device is reseated/replaced/repaired.YesAny
Temperature - Message Code: "x11xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1114Temp AmbientMedAmbient temperature has a reached a point outside of the allowed range.Temperature returns to allowable range.YesAny
E1116Temp MemoryHighMemory has exceeded allowable temperature and has been disabled to prevent damage to the components.AC Cycle or SEL clearYesAny
Voltages - Message Code: "x12xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1210CMOSBattLowCMOS battery is missing or the voltage is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAny
E1211ROMBBattLowPERC5I RAID battery charger has reported to the Server Management that the battery is either missing, can't charge the battery (possibly because of high temperatures), or the battery is bad.Failing device is reseated/replaced/repaired.YesAny
W1228ROMBBatt< 24 hrLowThis is a predictive failure warning message telling the user that the PERC5I RAID battery has less then 24 hours of charge left init. We provide this message as a warning message to the customer.Battery charges to > 24 hours of sustained charge.YesAny
E12141.5VPwrGdHigh1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E12151.8VPwrGdHigh1.8 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E12163.3VPwrGdHigh3.3 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E12175VPwrGdHigh5 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E1218PCIRsr5VPwrGdHighPCI Riser 5 V voltage regulator has failed.AC Cycle or SEL clearYesAny
E1219BackplanePwrGdHighBackplane voltage regulator has failed.AC Cycle or SEL clearYesAny
E1221Flex BayPwrGdHighFlex Bay voltage regulator power good has failed.AC Cycle or SEL clearYesAny
E1222VCACHE #PwrGdHighVCACHE # voltage regulator has failed.AC Cycle or SEL clearYesAny
E1223VRM #PwrGdHighVRM # voltage regulator has failed.AC Cycle or SEL clearYesAny
E1225ESB 1.5VPwrGdHighESB 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E1226PCIRsr1.5VPwrGdHighPCI Riser 1.5 VV voltage regulator has failed.AC Cycle or SEL clearYesAny
E1227LinearPwrGdHighLinear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry.AC Cycle or SEL clearYesAny
E12280.9VPwrGdHighMemory VTT voltage regulator has failed.AC Cycle or SEL clearYesAny
E1229CPU # VCOREHighProcessor # VCORE voltage regulator has failed.AC Cycle or SEL clearYesAny
E122ACPU VTTPwrGdHighProcessor VTT voltage regulator has failed.AC Cycle or SEL clearYesAny
E122B0.9 V Over VoltageHigh0.9 V regulator voltage has exceeded the allowable voltage range.AC Cycle or SEL clearYesAny
E122CCPU Power FaultHighA voltage regulator failure was detected when the processor regulator(s) was enabled.AC Cycle or SEL clearYesAny
Fans - Message Code: "x13xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1310RPM Fan ##LowRPM of fan ## is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #ALowRPM of fan A in the # module is outside of the intended operating range.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #BLowSame as above except for fan B of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #CLowSame as above except for fan C of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1311RPM Fan Mod #DLowSame as above except for fan D of module #.Fan RPM reading returns to a point inside of the intended operating range.YesAny
E1313Fan RedundancyLowThe system is no longer fan redundant. Another fan failure would put the system at risk of over-heating.Fan redundancy is regained, which requires all fans to be operating within the intended operating range.YesAny
Processors - Message Code: "x14xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1410CPU # IERRHighProcessor # has had an internal error (IERR), but this does not always mean that CPU is the problem .There are a large variety of issues that cause an IERR.AC Cycle or SEL clearYesAny
E1414CPU #ThermtripHighProcessor # has encountered a Thermtrip(over-temperature) event.AC Cycle or SEL clearYesAny
E1418CPU # PresenceHighProcessor # is missing/bad and the system is in an unsupported configuration.AC Cycle or SEL clearYesPre-POST
E141CCPU MismatchHighProcessors are not compatible as defined by Dell .System is in an unsupported configuration.AC Cycle or SEL clearYesPre-POST
E141FCPU ProtocolHighBIOS has reported a processor protocol error.AC Cycle or SEL clearYesPOST, After POST
E1420CPU Bus PERRHighBIOS has reported a processor bus PERR (parity error).AC Cycle or SEL clearYesPOST, After POST
E1421CPU InitHighBIOS has reported a processor initialization error.AC Cycle or SEL clearYesPOST, After POST
E1422CPU MachineChkHighBIOS has reported a machine check error.AC Cycle or SEL clearYesPOST, After POST
System Memory - Message Code: "x21xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E2110MBECrdx DIMM ## & ##HighOne of the DIMMs in the set implicated by "## & ##" has had a multi-bit error (MBE).If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.AC Cycle or SEL clearYesPOST, After POST
E2111SBE Log DisableCrdx DIMM ##HighBIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEE's until the system is rebooted.## represents DIMM implicated by BIOS .If no memory riser is present the “Crd x” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
E2112MemSpareCrdx DIMM ##HighBIOS has spared the memory because it has determined the memory had too many errors.## represents DIMM implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
E2113Mem Mirror Crd x DIMM ## & ##HighBIOS has disabled memory mirroring because it has determined one half of the mirror has had too many errors. ## & ## represents DIMM pair implicated by BIOS. If no memory riser is present the “Crdx” string is left out of the message.“x” is the memory riser, A-Z.System resetYesPOST, After POST
I2114MemRaidLowBIOS Memory RAID BankUser action, sensor return to normalYesAny
I2115MemAdded Card xLowMemory has been added while the system is running.AC Cycle or SEL clearYesAny
I2116MemRemovedLowMemory has been removed while the system is running.AC Cycle or SEL clearYesAny
E2117MemHot PlugLowMemory hot-plug operation has failed.AC Cycle or SEL clearYesAny
E2118Fatal NBMemCRCHighNorthbound FBD CRC error on non-redundant entry. One of the connections in the FBD link on the Northbound (towards the MCH) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POST
E2119Fatal SBMemCRCHighFBD alert on non-redundant entry. One of the connections in the FBD link on the Southbound (towards the AMB'son the FBDIMM's) side is "broken".This is determined by the MCH when two CRC errors have been detected twice in a row.AC Cycle or SEL clearYesPOST, After POST

 

Power Supplies - Message Code: "x16xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1610PS # MissingLowPower supply # was removed or is missing from the system.Failing device is reseated/replaced/repaired.YesAny
E1614PS # StatusLowPower supply # has failed.Failing device is reseated/replaced/repaired.YesAny
E1618PS # PredictiveLowPower supply # has a failure that predicts a power down event in this supply (i.e. power supply fan failure or power supply over-temp).Failing device is reseated/replaced/repaired.YesAny
E161CPS # Input LostLowPower supply # is attached to the system but has lost its AC/DC input.Failing device is reseated/replaced/repaired.YesAny
E1620PS #Input RangeLowPower supply #'s AC/DC input is outside of the allowable range.Failing device is reseated/replaced/repaired.YesAny
E1624PS RedundancyLowThe power supply subsystem is no longer redundant. If the last supply fails the system will go down.Failing device is reseated/replaced/repaired.YesAny
E1625PS AC CurrentLowThe power supply input power is above the allowed amount for the power supply.Failing device is reseated/replaced/repaired.YesAny
BIOS - Message Code: "x17xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1710I/O ChannelChkHighBIOS has reported an I/O channel check.AC Cycle or SEL clearYesPOST, After POST
E1711PCI PERR B## D## F##HighBIOS has reported PCI parity error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E1711PCI PERR Slot #HighBIOS has reported PCI parity error on a component that resides in slot #.Same as above.Same as above.Same as above.
E1712PCI SERR B## D## F##HighBIOS has reported a PCI system error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E1712PCI SERR Slot #HighBIOS has reported a PCI system error on a component that resides in slot #.Same as above.Same as above.Same as above.
E1714Unknown ErrLowBIOS has determined there has been an error in the system but is unable to determine its origin.AC Cycle or SEL clearYesPOST, After POST
E171FPCIE Fatal Err B## D## F##HighBIOS has reported a PCIe fatal error on a component that resides in PCI configuration space at bus ##, device ##, function ##.AC Cycle or SEL clearYesPOST, After POST
E171FPCIE Fatal Slot #HighBIOS has reported a PCIe fatal error on a component that resides in slot #.Same as above.Same as above.Same as above.
Hard Drives - Message Code: "x18xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1810HDD ## FaultLowHard drive ## has had a fault as determined by the SAS subsystem.AC Cycle or SEL clearYesPOST, After POST
E1811HDD ##RbldAbrtLowDrive ## has had its rebuild aborted.AC Cycle or SEL clearYesPOST, After POST
E1812HDD ## RemovedLowDrive ## has been removed from the system.System reset or device is reseated/replaced/repaired.YesPOST, After POST
Miscellaneous - Message Code: "x19xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
I1910IntrusionLowThe chassis lid has been removed.Chassis lid is returned to the system.YesAny
I1911>3ERRsChkLogN/AUser must check the system event log (SEL) for the rest of the errors on the system .Thee LCD is limited to three error, warning, and/or informational messages at a time based on priority level.Less than 3 events to display on the LCD.NoAny
I1912SEL FullMedSystem Event Log is full of events and because of this is unable to log anymore. You must clear the log in order for the Server Management controller to log any more events.AC Cycle or SEL clearYesAny
E1913CPU & Firmware MismatchMedCurrent version of BMC firmware is incompatible with the Woodcrest processor.AC Cycle or SEL clearYesPOST
BIOS Progress Codes - Message Code: N/A
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
N/APOWERN/A0x01 -- System power-on.N/ANoAny
N/AMCODEN/A0x02 -- CPU Microcode load.N/ANoAny
N/ACINITN/A0x03 -- Chipset Initialization.N/ANoAny
N/AMEMCN/A0x04 -- Memory Configuration.N/ANoAny
N/ASBIOSN/A0x05 -- BIOS shadow into memory.N/ANoAny
N/APINITN/A0x06 -- Multiprocessor Initialization.N/ANoAny
N/ASTARTN/A0x07 -- POST processing start.N/ANoAny
N/ASMMN/A0x08 -- System management interrupt (SMI) initialization.N/ANoAny
N/APCIENN/A0x09 -- PCI Bus Enumeration & Video initialization.N/ANoAny
N/AVIDEON/A0x40 -- Display sign-on.N/ANoAny
N/APCICN/A0x41 -- PCI Configuration.N/ANoAny
N/AOSN/A0x7F -- Give control to OS.N/ANoAny
N/AE2010N/A0x80 -- No memory installed in the system.N/ANoAny
N/AE2011N/A0x81 -- Memory detected but is not configurable .Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.N/ANoAny
N/AE2012N/A0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.N/ANoAny
N/AE2013N/A0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.N/ANoAny
N/AE2014N/A0x84 -- CMOS failure. CMOS'S RAM not working.N/ANoAny
N/AE1215N/A0x05 -- DMA controller failure.N/ANoAny
N/AE1116N/A0x80 -- Interrupt controller failure.N/ANoAny
N/AE1217N/A0x07 -- Timer refresh failure.N/ANoAny
N/AE1218N/A0x28 -- Programmable interval timer error.N/ANoAny
N/AE0119N/A0x29 -- Parity error.N/ANoAny
N/AE122AN/A0x2a -- SIO failure.N/ANoAny
N/AE122BN/A0x00b0 -- Keyboard controller failure.N/ANoAny
N/AE141CN/A0x3c -- System management interrupt (SMI) initialization failure.N/ANoAny
N/AE.11N/A0xC4 -- BIOS shutdown test failure.N/ANoAny
N/AE.11N/A0xC4 -- BIOS POST memory test failure. Could be the result of bad memory.N/ANoAny
N/AE141FN/A0xC4 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.N/ANoAny
N/AE0000N/A0xC4 -- CPU configuration failure. Check screen for the actual error message.N/ANoAny
N/AE1221N/A0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.N/ANoAny
N/AE1222N/A22x -- General failure after video. Check screen for the actual error message.N/ANoAny
BIOS Fatal Error Codes - Message Code: "x20xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E2010No MemoryHigh0x80 -- No memory installed in the system.System resetYesPOST
E2011MemConfigErrHigh0x81 -- Memory detected but is not configurable. Error detected during memory configuration. Could be result of bad memory, mismatched memory or bad socket.System resetYesPOST
E2012Unusable MemoryHigh0x82 -- Memory configured but not usable. Memory sub-system failure. Could be the result of bad memory.System resetYesPOST
E2013Shadow BIOS FailHigh0x83 -- BIOS failed to copy its flash image into memory. Could be the result of bad memory.System resetYesPOST
E2014CMOS FailHigh0x84 -- CMOS failure. CMOS'S RAM not working.System resetYesPOST
E2015DMA ControllerHigh0x85 -- DMA controller failure.System resetYesPOST
E2016IntControllerHigh0x86 -- Interrupt controller failure.System resetYesPOST
E2017Timer FailHigh0x87 -- Timer refresh failure.System resetYesPOST
E2018ProgTimerHigh0x88 -- Programmable interval timer error.System resetYesPOST
E2019Parity ErrorHigh0x89 -- Parity error.System resetYesPOST
E201ASIO ErrHigh0x8A -- SIO failure.System resetYesPOST
E201BKybdControllerHigh0x8B -- Keyboard controller failure.System resetYesPOST
E201CSMI InitHigh0x8C -- System management interrupt (SMI) initialization failure.System resetYesPOST
E201DShutdown TestHigh0xC0 -- BIOS shutdown test failure.System resetYesPOST
E201EPOSTMemTestHigh0xC1 -- BIOS POST memory test failure. Could be the result of bad memory.System resetYesPOST
E201FDRACConfigHigh0xC2 -- Dell remote access controller (DRAC) configuration failure. Check screen for the actual error message.System resetYesPOST
E2020CPUConfigHigh0xC3 -- CPU configuration failure. Check screen for the actual error message.System resetYesPOST
E2021Memory PopulationHigh0xC4 -- Incorrect memory configuration. Memory population order not correct. Refer to the user guide.System resetYesPOST
E2022POST FailHigh0xFE -- General failure after video. Check screen for the actual error message.System resetYesPOST
Special Exceptions - Message Code: "x10xx"
Message CodeMessage StringMessage PriorityMessage CommentsMinimum Action Required to Remove Message from LCDExists in SEL?System Phase When Event Can Occur?
E1000Failsafe, Call SupportSpecialCheck System Event Log for critical failure details.AC Cycle or SEL clearYesAny
  • 0
    点赞
  • 5
    收藏
    觉得还不错? 一键收藏
  • 1
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论 1
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值