1查看机器型号SN
查看机器型号,SN IBM,9117-MMA IBM,02065D746 |
2查看操作系统版本---便于解决问题和重装OS
查看系统的maintenance level DB2Server[/]#oslevel -s 5300-06-08-0831 DB2Server[/]#oslevel -r 5300-06 DB2Server[/]# |
3查看硬盘大小、型号及槽位
其他硬盘键入:#lsdev -CHc disk DB2Server[/]#lsdev -CHc disk name status location description
hdisk0 Available 0E-08-00 SAS Disk Drive hdisk1 Available 0G-08-00 SAS Disk Drive hdisk2 Available 04-00-01 1814 DS4700 Disk Array Device hdisk3 Available 04-00-01 1814 DS4700 Disk Array Device hdisk4 Available 04-00-01 1814 DS4700 Disk Array Device hdisk5 Available 04-00-01 1814 DS4700 Disk Array Device hdisk6 Available 04-00-01 1814 DS4700 Disk Array Device hdisk7 Available 04-00-01 1814 DS4700 Disk Array Device hdisk8 Available 04-00-01 1814 DS4700 Disk Array Device hdisk9 Available 04-00-01 1814 DS4700 Disk Array Device DB2Server[/]#
查看物理硬盘数量及所属卷组 DB2Server[/]#lspv hdisk0 00c5d7468c32f756 rootvg active hdisk1 00c5d746efe6bb4b rootvg active
hdisk2 00c5d746efe670fc datavg active hdisk3 00c5d746efe6716e datavg active
hdisk4 00c5d746efe7b4ae db2vg active hdisk5 00c5d746f0132da3 db2vg active
hdisk6 00c5d746f01469bc oravg active
hdisk7 00c5d746f01561fb wasvg
hdisk8 00c5d746f016480d tsmvg active
hdisk9 00c5d5b6f25bae3e spavg DB2Server[/]#lspath Available ses0 sas0 Available ses1 sas0 Enabled hdisk0 sas0 Missing ses2 sas1 Available ses3 sas2 Available ses4 sas2 Enabled hdisk1 sas2
列出所有的磁盘设备
DB2Server[/]#lsdev -Cc disk hdisk0 Available 0E-08-00 SAS Disk Drive hdisk1 Available 0G-08-00 SAS Disk Drive hdisk2 Available 04-00-01 1814 DS4700 Disk Array Device hdisk3 Available 04-00-01 1814 DS4700 Disk Array Device hdisk4 Available 04-00-01 1814 DS4700 Disk Array Device hdisk5 Available 04-00-01 1814 DS4700 Disk Array Device hdisk6 Available 04-00-01 1814 DS4700 Disk Array Device hdisk7 Available 04-00-01 1814 DS4700 Disk Array Device hdisk8 Available 04-00-01 1814 DS4700 Disk Array Device hdisk9 Available 04-00-01 1814 DS4700 Disk Array Device
查看硬盘的容量
DB2Server[/]#bootinfo -s hdisk0 140013 DB2Server[/]#bootinfo -s hdisk1 140013 DB2Server[/]#bootinfo -s hdisk2 409600 DB2Server[/]#bootinfo -s hdisk3 409600 DB2Server[/]#bootinfo -s hdisk4 307200 DB2Server[/]#bootinfo -s hdisk5 307200 DB2Server[/]#bootinfo -s hdisk6 307200 DB2Server[/]#bootinfo -s hdisk7 0 DB2Server[/]#bootinfo -s hdisk8 118360 DB2Server[/]#bootinfo -s hdisk9 0
查看磁盘属性
DB2Server[/]#lsattr -El hdisk0 PCM PCM/friend/scsiscsd Path Control Module False algorithm fail_over Algorithm True dist_err_pcnt 0 Distributed Error Percentage True dist_tw_width 50 Distributed Error Sample Time True hcheck_interval 0 Health Check Interval True hcheck_mode nonactive Health Check Mode True max_transfer 0x100000 Maximum TRANSFER Size True pvid 00c5d7468c32f7560000000000000000 Physical volume identifier False queue_depth 16 Queue DEPTH False reserve_policy no_reserve Reserve Policy True size_in_mb 146800 Size in Megabytes False ww_id 5000c5002879ec9f World Wide Identifier False DB2Server[/]#
DB2Server[/]#lsattr -El hdisk1 PCM PCM/friend/scsiscsd Path Control Module False algorithm fail_over Algorithm True dist_err_pcnt 0 Distributed Error Percentage True dist_tw_width 50 Distributed Error Sample Time True hcheck_interval 0 Health Check Interval True hcheck_mode nonactive Health Check Mode True max_transfer 0x100000 Maximum TRANSFER Size True pvid 00c5d746efe6bb4b0000000000000000 Physical volume identifier False queue_depth 16 Queue DEPTH False reserve_policy no_reserve Reserve Policy True size_in_mb 146800 Size in Megabytes False ww_id 5000c5002879e6ab World Wide Identifier False
DB2Server[/]#lsattr -El hdisk2 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E50001868B4000007134D084768 IEEE Unique volume name False lun_id 0x0000000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746efe670fc0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11700 SCSI ID False size 409599 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#
DB2Server[/]#lsattr -El hdisk3 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E5000186B2C000006F14D084786 IEEE Unique volume name False lun_id 0x0001000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746efe6716e0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11500 SCSI ID False size 409599 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#
DB2Server[/]#lsattr -El hdisk4 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E50001868B4000007164D0847A6 IEEE Unique volume name False lun_id 0x0002000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746efe7b4ae0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11700 SCSI ID False size 307199 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#lsattr -El hdisk5 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E5000186B2C000006F44D0847C1 IEEE Unique volume name False lun_id 0x0003000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746f0132da30000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11500 SCSI ID False size 307199 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#
DB2Server[/]#lsattr -El hdisk6 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E50001868B4000007184D0847CC IEEE Unique volume name False lun_id 0x0004000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746f01469bc0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11700 SCSI ID False size 307199 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#lsattr -El hdisk7 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E5000186B2C000006F64D084804 IEEE Unique volume name False lun_id 0x0005000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746f01561fb0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11500 SCSI ID False size 102399 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#lsattr -El hdisk8 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E50001868B40000071C4D08483C IEEE Unique volume name False lun_id 0x0006000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d746f016480d0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11700 SCSI ID False size 118359 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#
DB2Server[/]#lsattr -El hdisk9 PR_key_value none Persistant Reserve Key Value True cache_method default Write Caching method False ieee_volname 60080E5000186B2C0000084C4D0A889F IEEE Unique volume name False lun_id 0x0007000000000000 Logical Unit Number False max_transfer 0x100000 Maximum TRANSFER Size True prefetch_mult 0 Multiple of blocks to prefetch on read False pvid 00c5d5b6f25bae3e0000000000000000 Physical volume identifier False q_type simple Queuing Type False queue_depth 10 Queue Depth True raid_level 5 RAID Level False reassign_to 120 Reassign Timeout value True reserve_policy single_path Reserve Policy True rw_timeout 30 Read/Write Timeout value True scsi_id 0x11500 SCSI ID False size 51199 Size in Mbytes False write_cache no Write Caching enabled False DB2Server[/]#
DB2Server[/]#lscfg -vpl hdisk0 hdisk0 U789D.001.DQD0K3V-P3-D1 SAS Disk Drive (146800 MB)
Manufacturer................IBM Machine Type and Model......ST3146356SS FRU Number..................10N7204 ROS Level and ID............45363130 Serial Number...............3QN4LGWR EC Level....................D76038 Part Number.................10N7203 Device Specific.(Z0)........000005329F003002 Device Specific.(Z1)........0617E610 Device Specific.(Z2)........0021 Device Specific.(Z3)........10265 Device Specific.(Z4)........ Device Specific.(Z5)........22 Device Specific.(Z6)........D76038 Hardware Location Code......U789D.001.DQD0K3V-P3-D1
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]# DB2Server[/]#lscfg -vpl hdisk1 hdisk1 U789D.001.DQD0H8P-P3-D1 SAS Disk Drive (146800 MB)
Manufacturer................IBM Machine Type and Model......ST3146356SS FRU Number..................10N7204 ROS Level and ID............45363130 Serial Number...............3QN4L182 EC Level....................D76038 Part Number.................10N7203 Device Specific.(Z0)........000005329F001002 Device Specific.(Z1)........0617E610 Device Specific.(Z2)........0021 Device Specific.(Z3)........10265 Device Specific.(Z4)........ Device Specific.(Z5)........22 Device Specific.(Z6)........D76038 Hardware Location Code......U789D.001.DQD0H8P-P3-D1
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk2 hdisk2 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L0 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk3 hdisk3 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L1000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk4 hdisk4 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L2000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk5 hdisk5 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L3000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk6 hdisk6 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L4000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk7 hdisk7 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L5000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk8 hdisk8 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L6000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]#lscfg -vpl hdisk9 hdisk9 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4-L7000000000000 1814 DS4700 Disk Array Device
PLATFORM SPECIFIC
Name: disk Node: disk Device Type: block DB2Server[/]# |
4查看内存信息(物理内存总量、插槽、单条内存大小)
查看内存 DB2Server[/]#lsdev -Cc memory L2cache0 Available L2 Cache mem0 Available Memory DB2Server[/]#lsattr -El mem0 goodsize 31104 Amount of usable physical memory in Mbytes False size 31104 Total amount of physical memory in Mbytes False DB2Server[/]#bootinfo -r 31850496 DB2Server[/]#prtconf System Model: IBM,9117-MMA Machine Serial Number: 065D746 Processor Type: PowerPC_POWER6 Processor Implementation Mode: POWER 6 Processor Version: PV_6 Number Of Processors: 8 Processor Clock Speed: 4400 MHz CPU Type: 64-bit Kernel Type: 64-bit LPAR Info: 1 06-5D746 Memory Size: 31104 MB Good Memory Size: 31104 MB Platform Firmware level: EM350_085 Firmware Version: IBM,EM350_085 Console Login: enable Auto Restart: true Full Core: false
Network Information Host Name: DB2Server IP Address: 172.168.2.1 Sub Netmask: 255.255.255.0 Gateway: 10.114.20.254 Name Server: Domain Name:
Paging Space Information Total Paging Space: 28672MB Percent Used: 1%
Volume Groups Information ============================================================================== rootvg: PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION hdisk0 active 546 0 00..00..00..00..00 hdisk1 active 546 126 00..00..00..17..109 ==============================================================================
datavg: PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION hdisk2 active 799 409 00..00..89..160..160 hdisk3 active 799 378 20..00..38..160..160 ==============================================================================
db2vg: PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION hdisk4 active 599 177 00..00..00..57..120 hdisk5 active 599 200 00..119..81..00..00 ==============================================================================
oravg: PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION hdisk6 active 1199 216 00..00..00..00..216 ==============================================================================
0516-010 : Volume group must be varied on; use varyonvg command. ==============================================================================
tsmvg: PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION hdisk8 active 462 61 00..00..00..00..61 ==============================================================================
0516-010 : Volume group must be varied on; use varyonvg command. ==============================================================================
INSTALLED RESOURCE LIST
The following resources are installed on the machine. +/- = Added or deleted from Resource List. * = Diagnostic support not available.
Model Architecture: chrp Model Implementation: Multiple Processor, PCI bus
+ sys0 System Object + sysplanar0 System Planar * vio0 Virtual I/O Bus * vsa0 U9117.MMA.065D746-V1-C0 LPAR Virtual Serial Adapter * vty0 U9117.MMA.065D746-V1-C0-L0 Asynchronous Terminal * pci13 U789D.001.DQD0H8P-P1 PCI Express Bus * pci12 U789D.001.DQD0H8P-P1 PCI Express Bus * pci18 U789D.001.DQD0H8P-P1-C3 PCI Bus * pci11 U789D.001.DQD0H8P-P1 PCI Express Bus + fcs4 U789D.001.DQD0H8P-P1-C2-T1 4Gb FC PCI Express Adapter (df1000fe) * fscsi4 U789D.001.DQD0H8P-P1-C2-T1 FC SCSI I/O Controller Protocol Device * fcnet4 U789D.001.DQD0H8P-P1-C2-T1 Fibre Channel Network Protocol Device + fcs5 U789D.001.DQD0H8P-P1-C2-T2 4Gb FC PCI Express Adapter (df1000fe) * fscsi5 U789D.001.DQD0H8P-P1-C2-T2 FC SCSI I/O Controller Protocol Device * fcnet5 U789D.001.DQD0H8P-P1-C2-T2 Fibre Channel Network Protocol Device * pci10 U789D.001.DQD0H8P-P1 PCI Express Bus + ent2 U789D.001.DQD0H8P-P1-C1-T1 2-Port Gigabit Ethernet-SX PCI-Express Adapter (14103f03) + ent3 U789D.001.DQD0H8P-P1-C1-T2 2-Port Gigabit Ethernet-SX PCI-Express Adapter (14103f03) * pci9 U789D.001.DQD0H8P-P1 PCI Bus * pci8 U789D.001.DQD0H8P-P1 PCI Bus * pci7 U789D.001.DQD0H8P-P1 PCI Bus * pci16 U789D.001.DQD0H8P-P1 PCI Bus + sissas2 U789D.001.DQD0H8P-P1-T3 PCI-X266 Planar 3Gb SAS Adapter * sas2 U789D.001.DQD0H8P-P1-T3 Controller SAS Protocol + ses3 U789D.001.DQD0H8P-P3-Y2 SAS Enclosure Services Device + ses4 U789D.001.DQD0H8P-P3-Y1 SAS Enclosure Services Device + hdisk1 U789D.001.DQD0H8P-P3-D1 SAS Disk Drive (146800 MB) * sata2 U789D.001.DQD0H8P-P1-T3 Controller SATA Protocol * pci17 U789D.001.DQD0H8P-P1 PCI Bus + usbhc2 U789D.001.DQD0H8P-P1 USB Host Controller (33103500) + usbhc3 U789D.001.DQD0H8P-P1 USB Host Controller (33103500) * pci6 U789D.001.DQD0K3V-P1 PCI Express Bus * pci5 U789D.001.DQD0K3V-P1 PCI Express Bus + fcs2 U789D.001.DQD0K3V-P1-C3-T1 4Gb FC PCI Express Adapter (df1000fe) * fscsi2 U789D.001.DQD0K3V-P1-C3-T1 FC SCSI I/O Controller Protocol Device * rmt0 U789D.001.DQD0K3V-P1-C3-T1-W2008000E1114065B-L0 IBM 3580 Ultrium Tape Drive (FCP) * rmt1 U789D.001.DQD0K3V-P1-C3-T1-W2002000E1114065B-L0 IBM 3580 Ultrium Tape Drive (FCP) * smc0 U789D.001.DQD0K3V-P1-C3-T1-W2002000E1114065B-L1000000000000 IBM 3573 Tape Medium Changer (FCP) * fcnet2 U789D.001.DQD0K3V-P1-C3-T1 Fibre Channel Network Protocol Device + fcs3 U789D.001.DQD0K3V-P1-C3-T2 4Gb FC PCI Express Adapter (df1000fe) * fscsi3 U789D.001.DQD0K3V-P1-C3-T2 FC SCSI I/O Controller Protocol Device * fcnet3 U789D.001.DQD0K3V-P1-C3-T2 Fibre Channel Network Protocol Device * pci4 U789D.001.DQD0K3V-P1 PCI Express Bus + fcs0 U789D.001.DQD0K3V-P1-C2-T1 4Gb FC PCI Express Adapter (df1000fe) * fscsi0 U789D.001.DQD0K3V-P1-C2-T1 FC SCSI I/O Controller Protocol Device * dac0 U789D.001.DQD0K3V-P1-C2-T1-W20150080E51868B4 1814 DS4700 Disk Array Controller * dac1 U789D.001.DQD0K3V-P1-C2-T1-W20140080E51868B4 1814 DS4700 Disk Array Controller * fcnet0 U789D.001.DQD0K3V-P1-C2-T1 Fibre Channel Network Protocol Device + fcs1 U789D.001.DQD0K3V-P1-C2-T2 4Gb FC PCI Express Adapter (df1000fe) * fscsi1 U789D.001.DQD0K3V-P1-C2-T2 FC SCSI I/O Controller Protocol Device * fcnet1 U789D.001.DQD0K3V-P1-C2-T2 Fibre Channel Network Protocol Device * pci3 |