将新插入磁盘的Frimware state修改为unconfig good
找到unconfig bad的磁盘
# ./MegaCli64 -pdlist -a0
Adapter #0
Enclosure Device ID: 252 Slot Number: 0 Drive's position: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: N/A Device Id: 2 WWN: 5000C50098BAA780 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098baa781 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RYEM FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :33C (91.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 1 Enclosure position: N/A Device Id: 3 WWN: 5000C50098BAE2D4 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Unconfigured(bad) Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bae2d5 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RXXY FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :24C (75.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 2 Drive's position: DiskGroup: 1, Span: 0, Arm: 1 Enclosure position: N/A Device Id: 4 WWN: 5000C50098CDA904 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098cda905 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7SGL0 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :31C (87.80 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 3 Drive's position: DiskGroup: 1, Span: 0, Arm: 2 Enclosure position: N/A Device Id: 5 WWN: 5000C50098BD9BF8 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bd9bf9 SAS Address(1): 0x0 Connected Port Number: 2(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RZ7Y FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :33C (91.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00
# ./MegaCli64 -pdinfo -physdrv[252:1] -a0
Enclosure Device ID: 252 Slot Number: 1 Enclosure position: N/A Device Id: 3 WWN: 5000C50098BAE2D4 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Unconfigured(bad) Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bae2d5 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RXXY FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :24C (75.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00 |
将unconfig bad修改为unconfig good
# ./MegaCli64 -PDMakeGood -Physdrv "[252:1]" -a0
Adapter: 0: EnclId-252 SlotId-1 state changed to Unconfigured-Good.
Exit Code: 0x00
|
查看Frimware state
# ./MegaCli64 -pdinfo -physdrv[252:1] -a0
Enclosure Device ID: 252 Slot Number: 1 Enclosure position: N/A Device Id: 3 WWN: 5000C50098BAE2D4 Sequence Number: 3 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Unconfigured(good), Spun Up Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bae2d5 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RXXY FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: Foreign Foreign Secure: Drive is not secured by a foreign lock key Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :24C (75.20 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00 |
清除新插入磁盘的foreign状态
# ./MegaCli64 -cfgforeign -clear -a0
Foreign configuration 0 is cleared on controller 0.
Exit Code: 0x00 # # # ./MegaCli64 -pdinfo -physdrv[252:1] -a0
Enclosure Device ID: 252 Slot Number: 1 Enclosure position: N/A Device Id: 3 WWN: 5000C50098BAE2D4 Sequence Number: 3 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Unconfigured(good), Spun Up Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bae2d5 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RXXY FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :38C (100.40 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00 |
将新插入的磁盘做RAID0,加VD
# ./MegaCli64 -LDGetProp -Cache -Lall -a0
Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAdaptive, Direct, No Write Cache if bad BBU Adapter 0-VD 1(target id: 1): Cache Policy:WriteThrough, ReadAhead, Direct, No Write Cache if bad BBU
Exit Code: 0x00 # # # ./MegaCli64 -cfgldadd -r0 [252:1] WB RA Direct -a0
Adapter 0: Created VD 2
Adapter 0: Configured the Adapter!!
Exit Code: 0x00 # # ./MegaCli64 -LDGetProp -Cache -Lall -a0
Adapter 0-VD 0(target id: 0): Cache Policy:WriteThrough, ReadAdaptive, Direct, No Write Cache if bad BBU Adapter 0-VD 1(target id: 1): Cache Policy:WriteThrough, ReadAhead, Direct, No Write Cache if bad BBU Adapter 0-VD 2(target id: 2): Cache Policy:WriteThrough, ReadAhead, Direct, No Write Cache if bad BBU
Exit Code: 0x00 # |
检查vd状态
# ./MegaCli64 -pdlist -a0
Adapter #0
Enclosure Device ID: 252 Slot Number: 0 Drive's position: DiskGroup: 0, Span: 0, Arm: 0 Enclosure position: N/A Device Id: 2 WWN: 5000C50098BAA780 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098baa781 SAS Address(1): 0x0 Connected Port Number: 0(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RYEM FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :35C (95.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 1 Drive's position: DiskGroup: 2, Span: 0, Arm: 0 Enclosure position: N/A Device Id: 3 WWN: 5000C50098BAE2D4 Sequence Number: 4 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bae2d5 SAS Address(1): 0x0 Connected Port Number: 3(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RXXY FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :42C (107.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 2 Drive's position: DiskGroup: 1, Span: 0, Arm: 1 Enclosure position: N/A Device Id: 4 WWN: 5000C50098CDA904 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098cda905 SAS Address(1): 0x0 Connected Port Number: 1(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7SGL0 FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :32C (89.60 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252 Slot Number: 3 Drive's position: DiskGroup: 1, Span: 0, Arm: 2 Enclosure position: N/A Device Id: 5 WWN: 5000C50098BD9BF8 Sequence Number: 2 Media Error Count: 0 Other Error Count: 0 Predictive Failure Count: 0 Last Predictive Failure Event Seq Number: 0 PD Type: SAS
Raw Size: 558.911 GB [0x45dd2fb0 Sectors] Non Coerced Size: 558.411 GB [0x45cd2fb0 Sectors] Coerced Size: 557.861 GB [0x45bb9000 Sectors] Sector Size: 512 Logical Sector Size: 512 Physical Sector Size: 512 Firmware state: Online, Spun Up Commissioned Spare : No Emergency Spare : No Device Firmware Level: B001 Shield Counter: 0 Successful diagnostics completion on : N/A SAS Address(0): 0x5000c50098bd9bf9 SAS Address(1): 0x0 Connected Port Number: 2(path0) Inquiry Data: SEAGATE ST600MM0006 B001S0M7RZ7Y FDE Capable: Not Capable FDE Enable: Disable Secured: Unsecured Locked: Unlocked Needs EKM Attention: No Foreign State: None Device Speed: 6.0Gb/s Link Speed: 6.0Gb/s Media Type: Hard Disk Device Drive: Not Certified Drive Temperature :35C (95.00 F) PI Eligibility: No Drive is formatted for PI information: No PI: No PI Port-0 : Port status: Active Port's Linkspeed: 6.0Gb/s Port-1 : Port status: Active Port's Linkspeed: 6.0Gb/s Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00 # |
参考:
http://mattshma.github.io/2015/07/21/megacli%E7%9B%91%E6%8E%A7%E7%A3%81%E7%9B%98/
https://supportforums.cisco.com/sites/default/files/legacy/4/0/2/43204-CIVS-HDD.pdf