PCI总线定义

 

PCI总线定义

[ 返回目录 ]

PCI 是 Peripheral Component Interconnect 的缩写

接口卡的外观

PCI 标准 32位/64位 接口卡
 ----------------------------------------------------------------
|    PCI         元件侧 (B面)                                  |
|                                                                |
|                                                                |
|                                                                |
|    ____     32 位引脚部分                    64 位引脚部分  ___|
|___|    |||||||--|||||||||||||||||--|||||||--||||||||||||||
         ^     ^  ^               ^  ^     ^  ^            ^
       b01   b11  b14           b49  b52 b62  b63          b94
PCI 5V 32/64位卡
|                                                optional        |
|    ____     32 位引脚部分                    64 位引脚部分  ___|
|___|    ||||||||||||||||||||||||||--|||||||--||||||||||||||
PCI 3.3V 32/64位卡
|                                                optional        |
|    ____     32 位引脚部分                    64 位引脚部分  ___|
|___|    |||||||--||||||||||||||||||||||||||--||||||||||||||

引脚定义

 

Pin+5V+3.3VUniversalDescription
A1TRST  Test Logic Reset
A2+12V  +12 VDC
A3TMS  Test Mde Select
A4TDI  Test Data Input
A5+5V  +5 VDC
A6INTA  Interrupt A
A7INTC  Interrupt C
A8+5V  +5 VDC
A9RESV01  Reserved VDC
A10+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A11RESV03  Reserved VDC
A12GND03(OPEN)(OPEN)Ground or Open (Key)
A13GND05(OPEN)(OPEN)Ground or Open (Key)
A14RESV05  Reserved VDC
A15RESET  Reset
A16+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A17GNT  Grant PCI use
A18GND08  Ground
A19RESV06  Reserved VDC
A20AD30  Address/Data 30
A21+3.3V01  +3.3 VDC
A22AD28  Address/Data 28
A23AD26  Address/Data 26
A24GND10  Ground
A25AD24  Address/Data 24
A26IDSEL  Initialization Device Select
A27+3.3V03  +3.3 VDC
A28AD22  Address/Data 22
A29AD20  Address/Data 20
A30GND12  Ground
A31AD18  Address/Data 18
A32AD16  Address/Data 16
A33+3.3V05  +3.3 VDC
A34FRAME  Address or Data phase
A35GND14  Ground
A36TRDY  Target Ready
A37GND15  Ground
A38STOP  Stop Transfer Cycle
A39+3.3V07  +3.3 VDC
A40SDONE  Snoop Done
A41SBO  Snoop Backoff
A42GND17  Ground
A43PAR  Parity
A44AD15  Address/Data 15
A45+3.3V10  +3.3 VDC
A46AD13  Address/Data 13
A47AD11  Address/Data 11
A48GND19  Ground
A49AD9  Address/Data 9
A52C/BE0  Command, Byte Enable 0
A53+3.3V11  +3.3 VDC
A54AD6  Address/Data 6
A55AD4  Address/Data 4
A56GND21  Ground
A57AD2  Address/Data 2
A58AD0  Address/Data 0
A59+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A60REQ64  Request 64 bit ???
A61VCC11  +5 VDC
A62VCC13  +5 VDC
     
A63GND  Ground
A64C/BE[7]#  Command, Byte Enable 7
A65C/BE[5]#  Command, Byte Enable 5
A66+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A67PAR64  Parity 64 ???
A68AD62  Address/Data 62
A69GND  Ground
A70AD60  Address/Data 60
A71AD58  Address/Data 58
A72GND  Ground
A73AD56  Address/Data 56
A74AD54  Address/Data 54
A75+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A76AD52  Address/Data 52
A77AD50  Address/Data 50
A78GND  Ground
A79AD48  Address/Data 48
A80AD46  Address/Data 46
A81GND  Ground
A82AD44  Address/Data 44
A83AD42  Address/Data 42
A84+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
A85AD40  Address/Data 40
A86AD38  Address/Data 38
A87GND  Ground
A88AD36  Address/Data 36
A89AD34  Address/Data 34
A90GND  Ground
A91AD32  Address/Data 32
A92RES  Reserved
A93GND  Ground
A94RES  Reserved
     
B1-12V  -12 VDC
B2TCK  Test Clock
B3GND  Ground
B4TDO  Test Data Output
B5+5V  +5 VDC
B6+5V  +5 VDC
B7INTB  Interrupt B
B8INTD  Interrupt D
B9PRSNT1  Reserved
B10RES  +V I/O (+5 V or +3.3 V)
B11PRSNT2  ??
B12GND(OPEN)(OPEN)Ground or Open (Key)
B13GND(OPEN)(OPEN)Ground or Open (Key)
B14RES  Reserved VDC
B15GND  Reset
B16CLK  Clock
B17GND  Ground
B18REQ  Request
B19+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
B20AD31  Address/Data 31
B21AD29  Address/Data 29
B22GND  Ground
B23AD27  Address/Data 27
B24AD25  Address/Data 25
B25+3.3V  +3.3VDC
B26C/BE3  Command, Byte Enable 3
B27AD23  Address/Data 23
B28GND  Ground
B29AD21  Address/Data 21
B30AD19  Address/Data 19
B31+3.3V  +3.3 VDC
B32AD17  Address/Data 17
B33C/BE2  Command, Byte Enable 2
B34GND13  Ground
B35IRDY  Initiator Ready
B36+3.3V06  +3.3 VDC
B37DEVSEL  Device Select
B38GND16  Ground
B39LOCK  Lock bus
B40PERR  Parity Error
B41+3.3V08  +3.3 VDC
B42SERR  System Error
B43+3.3V09  +3.3 VDC
B44C/BE1  Command, Byte Enable 1
B45AD14  Address/Data 14
B46GND18  Ground
B47AD12  Address/Data 12
B48AD10  Address/Data 10
B49GND20  Ground
B50(OPEN)GND(OPEN)Ground or Open (Key)
B51(OPEN)GND(OPEN)Ground or Open (Key)
B52AD8  Address/Data 8
B53AD7  Address/Data 7
B54+3.3V12  +3.3 VDC
B55AD5  Address/Data 5
B56AD3  Address/Data 3
B57GND22  Ground
B58AD1  Address/Data 1
B59VCC08  +5 VDC
B60ACK64  Acknowledge 64 bit ???
B61VCC10  +5 VDC
B62VCC12  +5 VDC
     
B63RES  Reserved
B64GND  Ground
B65C/BE[6]#  Command, Byte Enable 6
B66C/BE[4]#  Command, Byte Enable 4
B67GND  Ground
B68AD63  Address/Data 63
B69AD61  Address/Data 61
B70+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
B71AD59  Address/Data 59
B72AD57  Address/Data 57
B73GND  Ground
B74AD55  Address/Data 55
B75AD53  Address/Data 53
B76GND  Ground
B77AD51  Address/Data 51
B78AD49  Address/Data 49
B79+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
B80AD47  Address/Data 47
B81AD45  Address/Data 45
B82GND  Ground
B83AD43  Address/Data 43
B84AD41  Address/Data 41
B85GND  Ground
B86AD39  Address/Data 39
B87AD37  Address/Data 37
B88+5V+3.3VSignal Rail+V I/O (+5 V or +3.3 V)
B89AD35  Address/Data 35
B90AD33  Address/Data 33
B91GND  Ground
B92RES  Reserved
B93RES  Reserved
B94GND  Ground

  • 0
    点赞
  • 0
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值