To clarify you are experiencing the NMC/NMV inaccess issue, please try below first
1) when you try to log NMC via SSH, you are drectly logged into Bash shell.
2) /var/log/nms.log shows some DBus.timeout.error.
Either of above phenomenon indicates you are running into NMV/NMC inaccess issue.To recover from this, you need to restart NMS service as below.
NMS Restart Procedures:
2) Check the services with the following command from the appliance
svcs nm{s,v,cd} nbs nmdtrace dbus
STATE STIME FMRI
online 13:23:43 svc:/system/dbus:default
online 13:23:43 svc:/application/nbs:default
online 13:23:45 svc:/application/nmdtrace:default
online 13:23:51 svc:/application/nms:default <---- if this is online* nms is hung, this won't work
online 13:23:51 svc:/application/nmv:default
online 13:23:59 svc:/application/nmcd:default
3) Stop the services in this order:
svcadm disable svc:/application/nmv:default
svcadm disable svc:/application/nmcd:default
svcadm disable svc:/application/nms:default
svcadm disable svc:/system/dbus:default
4) Check that the services are disabled: (don't worry about the nmdtrace and nbs)
svcs nm{s,v,cd} nbs nmdtrace dbus
STATE STIME FMRI
disabled 13:18:49 svc:/application/nmv:default
disabled 13:18:51 svc:/application/nmcd:default
disabled 13:19:40 svc:/application/nms:default
disabled 13:19:41 svc:/system/dbus:default
offline 13:19:40 svc:/application/nmdtrace:default
offline 13:19:41 svc:/application/nbs:default
Wait until all services in step 4 are disabled. (don't worry about the nmdtrace and nbs) before proceeding.
svcadm enable svc:/system/dbus:default
svcadm enable svc:/application/nms:default
svcadm enable svc:/application/nmcd:default
svcadm enable svc:/application/nmv:default
6) Wait for about 30 seconds and check the services:
svcs nm{s,v,cd} nbs nmdtrace dbus
STATE STIME FMRI
online 13:23:43 svc:/system/dbus:default
online 13:23:43 svc:/application/nbs:default
online 13:23:45 svc:/application/nmdtrace:default
online 13:23:51 svc:/application/nms:default
online 13:23:51 svc:/application/nmv:default
online 13:23:59 svc:/application/nmcd:default
You should be able to now use NMV (GUI) or ssh into appliance as root and check it via NMC.