/usr/sun/bin 消失在4.0.2
A: anyone who knows why we delete /usr/sun/bin directory in the version 4.0.2?B: We don't. It is now simply /usr/binB: The GNU commands that were in /usr/bin are now in /usr/gnu/binA: okay, I s原创 2014-05-28 10:58:09 · 841 阅读 · 0 评论 -
How to run through the service reset procedure
run through the service reset procedure.This only affects user interfaces and will not interrupt your shares:please run the following from bash:# svcs nm{s,v} nmcd nbs nmdtrace dbus rmvolmgr r原创 2014-01-02 11:17:39 · 2707 阅读 · 0 评论 -
How to Update STEC Firmware from C18 to C23
Updating STEC FirmwareIntroductionThe instructions below explain how to upgrade the STEC ZeusRAM firmware. Procedures To obtain the latest firmware and utilities register for suppor转载 2014-01-02 14:00:47 · 2445 阅读 · 0 评论 -
intermittent disconnects of iscsi to vmware systems.
intermittent disconnects of iscsi to vmware systems.http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1033665To disable VAAI using the vSphere Client:转载 2013-12-31 15:00:44 · 1195 阅读 · 0 评论 -
Speed up resilver
A:do we have any standard higher than higher-than-normal priority numbers to use for resilvering?in other words:# echo zfs_resilver_delay/W1 |mdb -kw# echo zfs_resilver_min_time_ms/W0t4000|m原创 2013-10-25 10:21:59 · 1719 阅读 · 0 评论 -
Optimizing NexentaStor 3.1.4 for SSDs
IntroductionSSDs are the fastest data storage devices available today for computers and have a few characteristics that are different than HDDs. With a few minor modifications to sd.conf, you can ge转载 2013-11-12 22:47:33 · 1587 阅读 · 0 评论 -
auto-sync progress bar
Progress barWhy is the auto-sync progress bar not accurate? and is there a workaround?progress bar just doesn't work, workaround is - show auto-sync : stats -i 1or show auto-sync : prop原创 2013-11-23 01:28:19 · 737 阅读 · 0 评论 -
Best Practise for Runner/Service on Nexenta
NMV > Data Management > runner > ses-checkautosync-checksmart-collector选择disableNMV> Setting > Misc. Services >SNMP Agent -> disable选择disable原创 2013-11-22 16:59:45 · 880 阅读 · 0 评论 -
ZFS: Performance Tuning for Scrubs and Resilvers
http://broken.net/uncategorized/zfs-performance-tuning-for-scrubs-and-resilvers/ZFS: Performance Tuning for Scrubs and ResilversPosted onJuly 1, 2012 byJason MatthewsMy environme转载 2013-11-22 10:26:22 · 2684 阅读 · 0 评论 -
SNMP in NexnetaStor
SNMPSimple Network Management Protocol (SNMP) is a legacy network management protocol used to monitor and administer devices on the IP network. SNMP is standardized by the Internet Engineering Task转载 2013-11-07 23:14:18 · 1081 阅读 · 0 评论 -
2TB Seagate drive (00008527)
2TB Seagate drive from DELL will not power upDell R710 with 4 MD1200 Cabinets attached to dumb SAS controllers. Two of the cabs are populated with 12 600GB disks each. These work just fine. The转载 2013-11-21 10:32:33 · 942 阅读 · 0 评论 -
Cluster setup with Aggregates, VLAN's, and IPMP
Configuring clusters is complicated. It is even more complicated when you throw in complex network configurations demanded by some customers. This particular config has pretty much everything in it.转载 2013-11-05 11:17:47 · 1226 阅读 · 0 评论 -
workaround for SUP-664
The listed workaround in the bug details for SUP-664 are as following:-disable zfs-diagnosis in FMA from bash like this - this is to mitigate against the risk of more disks being classified as fai转载 2013-12-30 15:17:11 · 1577 阅读 · 0 评论 -
Drive Replacement Procedure via Nexenta NMC
======================================================================= Drive Replacement Procedure=======================================================================原创 2013-09-16 09:58:10 · 7775 阅读 · 0 评论 -
Identifying the replacement drive
From the bash shell, 'tail /var/adm/messages' to get the name of the new drive.Oct 28 20:42:47 nexenta01 scsi: [ID 583861 kern.info] sd147 at scsi_vhci0: unit-address g5000c50055bc69cb: f_symOct 28转载 2014-01-04 23:23:23 · 711 阅读 · 0 评论 -
谈谈 Zfs_vdev_max_pending
Zfs_vdev_max_pending :controls the maximum number of concurrent I/Os pending to each device.it's the queue depth to each vdevdefault is 10SAS - 10SATA - 4SSD - 32you can go higher than 10 depe转载 2014-05-28 14:13:43 · 1640 阅读 · 0 评论 -
Nexenta 4.0.2 开始允许一个VIP下有多个volume
摘要从Nexenta 4.0.2 版本开始,HA环境允许一个VIP下有多个volume,原创 2014-05-21 13:10:53 · 919 阅读 · 0 评论 -
rsfcli command
/opt/HAC/RSF-1/bin/rsfcli -i0 automatic/opt/HAC/RSF-1/bin/rsfcli -i0 manual/opt/HAC/RSF-1/bin/rsfcli -i0 status/opt/HAC/RSF-1/bin/rsfcli -i0 stop/opt/HAC/RSF-1/bin/rsfcli -i0 start原创 2014-01-23 15:12:06 · 919 阅读 · 0 评论 -
Auto-Sync tips
Nexenta gave me the below steps to use for diagnosing all current auto-sync issues. Would you be up for jumping on a call this afternoon(I am already booked this morning) to try these steps? Pleas转载 2013-10-17 23:56:02 · 1801 阅读 · 0 评论 -
zpool iostat <pool> 1 100的可信赖性
Q:Yes, the numbers you see there are meaningful. I will caution that they're isolated to a specific layer, so they don't fully explain what is going on and why. You may find that `zpool iostat原创 2014-05-02 09:18:34 · 1528 阅读 · 0 评论 -
How to release PGR3 reservation
Simple way to release reservation as belowroot@node2:/opt/HAC/RSF-1/bin# ./mhdc -d /dev/rdsk/c7t5000CCA01BC56074d0 -c PGR3_STATUS ★ check status[Thu Dec 12 10:09:43] MHDC(8731): device原创 2013-12-12 11:11:44 · 1681 阅读 · 0 评论 -
How to hot Restart HA after rsf config is modified
Use this process (same as above) to push it again to each node-----------------------------#copy this file to a new locationcp /opt/HAC/RSF-1/etc/config /opt/HAC/RSF-1/etc/config.update/原创 2013-12-22 13:11:47 · 1016 阅读 · 0 评论 -
How to install Collector tool on NexnetaStor prior to 3.1.5
How to install Collector tool on systems not on 3.1.5===========================================1. From NMC:option expert_mode=1!bash (hit y if prompted after this command to confirm)#原创 2013-11-16 23:25:49 · 2295 阅读 · 0 评论 -
How to determine slot assignments for disks - fdddd
How to determine slot assignments for disks - fddddFinding the disk slots from inside an OS when using generic hardware can be difficult. The attached script, fdddd, can be used to show the slot map转载 2013-10-01 21:29:34 · 1000 阅读 · 0 评论 -
How to reseat *faulted* HDD
I would recommend getting this relevant disk removed from the pool, and reseated in its slot before seeing if it can be added back into the slot again.1. Identify faulted logical drives using th原创 2013-12-30 15:02:49 · 1333 阅读 · 0 评论 -
Nexenta *Raidz* Disk replacement via NMV
Using NMV:1. Use your web browser to access to NMV.2. Go to "Data management" -> "Data sets"3. Select your (Volume/Pool)4. Identify your old disk and "click" on "replace"5. You wil原创 2014-01-02 12:43:38 · 1052 阅读 · 0 评论 -
NMS 强化小技巧
To help NMS:Steps that may help improve NMS stability======================================Increase the nms memory-check trigger threshold to restart the NMS process e.g. when it reaches原创 2013-11-05 11:02:16 · 1309 阅读 · 0 评论 -
3.1.5 Enhancements
•Auto-Sync and remote replication protocol (RRP) stability and performance enhancement.•RSF-1 HAC now uses persistent group reservations (PGR3) for placing reservations on disks in a cluster.转载 2013-10-31 16:08:00 · 1007 阅读 · 0 评论 -
Nexnetastor NMC/NMV 无法访问解决方案:重启NMS服务
To clarify you are experiencing the NMC/NMV inaccess issue, please try below first1) when you try to log NMC via SSH, you are drectly logged into Bash shell.2) /var/log/nms.log show some DBus time原创 2013-09-16 16:40:47 · 2534 阅读 · 0 评论 -
Deduplication in NexentaStor
Q: How do I use deduplication?Deduplication is a technique used to improve storage space efficiency by not storing redundant data. Deduplication occurs at the volume level -- all folders and zvols i原创 2013-09-16 16:35:17 · 1228 阅读 · 0 评论 -
Nexentastor online重复数据删除技术阐述
介绍数据重复删除技术是指删除数据存储或副本发送的多种方法,它可以减少存储数据空间和降低成本,在使用昂贵的网络链接时,降低传输成本。如果合理使用的话,数据重复删除技术可以通过删除I/O来改善性能。数据重复删除技术会作用于相同数据块的数据集。譬如,不同虚拟机图像虚拟化环境可共享客户操作系统副本,另外其他模块则独立于虚拟机。利用数据重复删除技术,仅独立于每个存储虚拟机的数据才需要进行存储操作。邮原创 2013-09-16 16:31:41 · 1200 阅读 · 0 评论 -
Nexenta Appliance Tuning
Do the following for both nodes:--------------------------------------------------Add these to the /etc/system file, for both nodes:set zfs:zfs_txg_timeout = 10set zfs:zfs_txg_synctime_ms =原创 2013-09-16 16:19:00 · 2281 阅读 · 0 评论 -
Storage rage: Like getting a nice steak and being told to only eat 80% of it
Storagebod Despite compression, dedupe and other ways people try to reduce and manage the amount of data that they store, it still seems that many storage infrastructure managers tend to waste many th转载 2013-09-16 11:17:33 · 1062 阅读 · 0 评论 -
How to switch trial to comercial license for HA without Internect connection on Nexenta
Step1:nmc$show appliance licensecheck current licenseStep2:nmc$setup appliance licenseSimply delete trial license and input the comercial license Step3: nmc$show appliance lice原创 2013-09-16 10:30:25 · 1304 阅读 · 0 评论 -
ZFS Folder Permissions (chmod) and ACL Settings on Nexenta
ZFS Folder Permissions (chmod) The simplest way of setting up permissions is probably using ACL's with inheritance instead of UNIX-type access rights. Set unix permissions of shared folder原创 2013-09-16 10:27:10 · 3657 阅读 · 0 评论 -
How to configure MPIO via iScsi/FC on Windows shared Zvol
This article applies to NexentaStor 3.1.3 and 3.1.3.5 and only affects Zvols that were created on those releases. It does not affect Zvols that were created prior to an upgrade.1) Steps to validat原创 2013-09-16 10:26:20 · 3675 阅读 · 0 评论 -
How to check iscsi issue on Nexenta
Hello,Please provide the following:/*-------------------------------------------------------------------------------------*/How to generate Support bundles: via NMC and ftp them:/*--------原创 2013-09-16 10:24:30 · 1224 阅读 · 0 评论 -
How to add VIP to HA cluster configuration
There are times when having a single Virtual Internet Protocol Address (VIP) tied to a Service Group of your HA Cluster is not sufficient, and multiple VIPs are required. A good example of this is whe原创 2013-09-16 10:23:05 · 1046 阅读 · 0 评论 -
How to optimize NexentaStor performance?
How to optimize NexentaStor performance?The first thing to remember is that if you do nothing but run NexentaStor with your data and SSDs, it will get faster automatically over time. There are alg转载 2013-09-16 10:28:06 · 1524 阅读 · 0 评论 -
Asynchronous Replication with NexentaStor
This document discusses variousasynchronous replication options with NexentaStor. NexentaStor provides twodifferent replication services, AutoTier and AutoSync.Both AutoSync and AutoTier supportincr原创 2013-09-16 16:46:27 · 1385 阅读 · 0 评论