NFPA中其他规范跟NEC的配合及其后缀字母的含义

第一部分 nec和nfpa的其他规范的协调和配合

三个层面,performance document,installation document 和 supporting document。

Protecting people and property from electrical hazards is a complex issue that, unfortunately, cannot be handled by a single code or standard. Due to the nature of these hazards, many different documents are needed in order to achieve the desired end result. These documents work together as part of a bigger picture to help save lives and prevent loss.

With respect to the National Electrical Code® (NEC®) and its interrelated documents, the following illustrates the three tiered approach to how these documents work together within the bigger picture.

 

Performance documents

These documents contain requirements for how a system is intended to perform. In other words, there is an objective to these documents that drives the design of the applicable system. They give the code or standard user an idea of what the system needs to do in order to accomplish the purpose of the document. Examples include the following: 

Installation documents

These documents contain the requirements for how to install the system in order to meet the objectives of the other performance level documents. They work together to help the code user know what to do and how to do it. Examples include:

Supporting documents

These documents feed information into the installation documents. They provide information about specific conditions that have special installation requirements. Examples of supporting documents include the following:

When we take a step back to look at the entire picture, the relationships between the different documents begin to take shape. It becomes clear how these documents form a partnership in order to achieve NFPA’s mission to help save lives and prevent loss. The performance and installation documents work together to build a system that is safe and achieves the desired objective, while the supporting documents provide information that is imperative to the proper system installation with the conditions present.

A fire alarm system is a great example of how these relationships work. Generally, a document other than the NEC — perhaps NFPA 101®, Life Safety Code®, or NFPA 5000®, Building Construction and Safety Code®, or the building code that is adopted and enforced within the jurisdiction — is the document that requires a fire alarm system to be installed. Once it has been determined that a fire alarm system is needed, NFPA 72, National Fire Alarm and Signaling Code, is used, which contains the requirements for how the system will need to be designed in order to meet the performance requirement. This includes detector placement requirements, notification requirements, inspection and maintenance requirements, and other requirements that will ensure that the system performs as needed. Ideally, this takes place during the design stage. The next stage is the physical installation of the fire alarm system. For these requirements, the NEC is used. The NEC contains requirements for the installation of the wiring and equipment of the fire alarm system. Requirements for items such as junction boxes, raceways, and cable types are found in the NEC. The NEC also contains the requirements for how to install these items, such as securing and supporting, fastening, and raceway fill. Together these two documents — the NEC and NFPA 72 — provide the requirements for installing a fire alarm system that meets the requirements of the building or life safety code. 

Sometimes an installation occurs in an environment that requires modification to the general installation materials and methods. This is where the supporting documents come in to play. The environment where this fire alarm system is being installed might contain conditions that warrant special modifications to the system. For instance, if the system is being installed within a facility that handles flammable gases and liquids, the level of hazard that is present needs to be determined in order to make the appropriate modifications. This type of information can be found in documents such as NFPA 497. Information found in this document will help determine which areas of the facility are classified and which are not. The installation code, in this case the NEC, is then used to modify the installation in the classified or hazardous areas of the facility. This provides a system that is installed safely in all conditions present and that will perform how it is required to.

Also within the NEC family of documents are NFPA 70B, Recommended Practice for Electrical Equipment Maintenance, and NFPA 70E®, Standard for Electrical Safety in the Workplace®. Together, these three documents — the NEC, NFPA 70B, and NFPA 70E — form a sort of three-legged stool for safe electrical installations. When the electrical system is installed properly per the NEC and maintained following the guidelines of NFPA 70B, all while using the work practices described in NFPA 70E, the system remains at the same level of safety as when it was installed. This ensures that the performance requirements to which the system was designed continue to be achieved. If a single leg of this stool is missing, the structure comes crumbling down. Even the highest quality electrical installation will fail if it is not properly serviced and maintained.(此段重点阐述了70,70E和70B的适用范围和统一性,另外NFPA经常发布handbook来相应的解释各个标准。)

There are also some documents that, due to the nature of their subject matter, are essentially stand-alone documents. While NFPA 77, Recommended Practice on Static Electricity, and NFPA 780, Standard for the Installation of Lightning Protection Systems, both deal with mitigating hazards that arise from electricity, static, and lightning, they are not part of the safe electrical system installation that is achieved by the NEC and its related documents. Because these documents are not part of the electrical system, they contain requirements that come from all three levels of protection: performance, installation, and supporting. They both are worth noting because they still fit within NFPA’s mission to help save lives and reduce loss.

第二部分 规范后各个后缀的意义

比如,ABCD经常表示不同的类型,要么是不同的建筑场所,要么是不同的小系统。而H表示的是NFPA发布的handbook,用来解释相对应的各个标准。

NFPA handbooks are helpful resources which aid the user in understanding the intent behind the code or standard’s requirements, along with colorful diagrams and photos, case studies, calculation tables, and much more.

Ever wonder what the difference is between an NFPA® handbook and a code or standard? We’re glad you asked.

NFPA codes and standards both provide requirements for achieving outcomes. Handbooks take a deeper dive, providing the full text of a code or standard as well as expert commentary and features such as graphics, decision trees, testing procedures, case studies, sample forms and checklists, and other helpful aids to give a better understanding of the reasoning behind the requirements and how to apply them.

JUST REMEMBER:

  • A code or standard is a framework—a set of rules to follow with a goal to achieve a certain result
  • A handbook is a connector—linking requirements to application by helping you understand the reasoning behind a code or standard
  • 0
    点赞
  • 1
    收藏
    觉得还不错? 一键收藏
  • 0
    评论

“相关推荐”对你有帮助么?

  • 非常没帮助
  • 没帮助
  • 一般
  • 有帮助
  • 非常有帮助
提交
评论
添加红包

请填写红包祝福语或标题

红包个数最小为10个

红包金额最低5元

当前余额3.43前往充值 >
需支付:10.00
成就一亿技术人!
领取后你会自动成为博主和红包主的粉丝 规则
hope_wisdom
发出的红包
实付
使用余额支付
点击重新获取
扫码支付
钱包余额 0

抵扣说明:

1.余额是钱包充值的虚拟货币,按照1:1的比例进行支付金额的抵扣。
2.余额无法直接购买下载,可以购买VIP、付费专栏及课程。

余额充值